Thermal Comfort Conditions at the Platforms of the Athens Metro

Abstract The current study aims at the comparison of the field measurements at the platforms of the Athens Metro with those recommended by international standard thermal comfort and to the investigation of the relationship of environmental parameters between platforms and the outdoor space. The levels of air, operative and globe temperature as well as air humidity and air velocity were continuously monitored at the platform space of two stations with different depth and design features in summer. The predicted mean vote (PMV) model and the predicted percentage of dissatisfied ( PPD ) index were used. The results reveal that the operative temperature at both stations is far from the traditional still-air comfort zones. For the case of elevated air movement of 1.2 ms -1 and considering the occupants have local control of air speed, 20.3% of the values at the station with the greatest depth do not exceed the upper limit. Furthermore, 64% of the variation in air temperature at the platform of the station with the smallest depth is explained by outdoor air temperature, while the corresponding percentage for the station with the greatest depth is 29%. Passengers experience sudden change of air temperature and PMV , especially at the station with the smallest depth, during their transition from the platform to the interior of air-conditioned train carriages and vice versa.

[1]  Jeong Tai Kim,et al.  Monitoring and prediction of indoor air quality (IAQ) in subway or metro systems using season dependent models , 2012 .

[2]  Environmental Performance of Underground Railway Stations in Athens , 2007 .

[3]  Graeme Maidment,et al.  Underground railway environment in the UK. Part 2: Investigation of heat load , 2004 .

[4]  Péter Ordódy THERMAL COMFORT IN THE PASSENGER AREAS OF THE BUDAPEST METRO , 2000 .

[5]  Soon-Bark Kwon,et al.  Indoor environment and passengers’ comfort in subway stations in Seoul , 2016 .

[6]  조영민,et al.  Status of PM in Seoul metropolitan subway cabins and effectiveness of subway cabin air purifier (SCAP) , 2014 .

[7]  Margarita N. Assimakopoulos,et al.  Particulate matter levels and comfort conditions in the trains and platforms of the Athens underground metro , 2016 .

[8]  M Santamouris,et al.  Indoor air quality in a metropolitan area metro using fuzzy logic assessment system. , 2013, The Science of the total environment.

[9]  Peter Kampstra,et al.  Beanplot: A Boxplot Alternative for Visual Comparison of Distributions , 2008 .

[10]  Richard D. Braatz,et al.  Indoor air quality control for improving passenger health in subway platforms using an outdoor air quality dependent ventilation system , 2015 .

[11]  Zhiwei Lian,et al.  Investigation of indoor environmental quality in Shanghai metro stations, China , 2010, Environmental monitoring and assessment.

[12]  Mohammad Jafari,et al.  Thermal comfort evaluation in Tehran metro using Relative Warmth Index , 2008 .

[13]  Christer Johansson,et al.  Particulate matter in the underground of Stockholm , 2002 .

[14]  Margarita N. Assimakopoulos,et al.  On the determination of the thermal comfort conditions of a metropolitan city underground railway. , 2016, The Science of the total environment.

[15]  Duckshin Park,et al.  Study on the Indoor Air Quality of Seoul Metropolitan Subway during the Rush Hour , 2008 .

[16]  Standard Ashrae Thermal Environmental Conditions for Human Occupancy , 1992 .

[17]  M. Minguillón,et al.  Factors controlling air quality in different European subway systems. , 2016, Environmental research.

[18]  A. Matzarakis,et al.  Dynamic modeling of human thermal comfort after the transition from an indoor to an outdoor hot environment , 2015, International Journal of Biometeorology.

[19]  Graeme Maidment,et al.  Underground railway environment in the UK Part 1: Review of thermal comfort , 2004 .