Evaluation of jet nebulisers for use with gentamicin solution.

Recently nebulised antibiotics (gentamicin and carbenicillin) have been used successfully to treat respiratory tract infection in patients with cystic fibrosis. No information exists, however, on the choice of nebuliser or the ideal mode of operation with antibiotic solutions, which are often viscous. The aerosol output, droplet size, and nebulisation time were assessed for four common brands of jet nebuliser (Bird, DeVilbiss, Inspiron, and Upmist) used to nebulise 2 ml (80 mg) and 4 ml (160 mg) of gentamicin solution (Garamycin, Kirby-Warrick) at four compressed gas flow rates (6, 8, 10, and 12 1 . min-1). There were considerable variations between the nebulisers, DeVilbiss and Upmist being most efficient in the release of respirable (less than 5 micron diameter) droplets. Droplet size and nebulisation time were inversely proportional to gas flow rate. Aerosol output and nebulisation time were increased by raising the volume fill from 2 to 4 ml, although nebulisation time could still be restricted to 12 minutes or less with DeVilbiss and Upmist at 12 1 . min-1. The output of drug in droplets of below 5 micron diameter ranged from 7.2 (SE 0.4) to 71.4 (4.3) mg, according to the type of nebuliser, flow rate, and volume fill. These studies suggest that for optimal drug delivery 4 ml gentamicin solution should be nebulised either at a fixed flow rate of 10-12 1 . min-1 or with a high flow compressor. Previous unsatisfactory clinical results with antibiotic aerosols may have been due in part to incorrect choice of nebuliser or inappropriate operating conditions, or both.

[1]  T. T. Mercer,et al.  Effect of auxiliary air flow on the output characteristics of compressed-air nebulizers. , 1969, Annals of allergy.

[2]  S. S. Davis,et al.  Physico-chemical studies on aerosol solutions for drug delivery I. Water-propylene glycol systems , 1978 .

[3]  P. Sterk,et al.  Physical properties of aerosols produced by several jet- and ultrasonic nebulizers. , 1984, Bulletin europeen de physiopathologie respiratoire.

[4]  K. Kilburn,et al.  Efficiency of nebulizers for depositing saline in human lung. , 1973, The American review of respiratory disease.

[5]  N. Southwell Inhaled penicillin in bronchial infections. , 1946, Lancet.

[6]  D. Pavia,et al.  Factors influencing the size distribution of aerosols from jet nebulisers. , 1983, Thorax.

[7]  M S Lin,et al.  Distal penetration in radioaerosol inhalation with an ultrasonic nebulizer. , 1974, Radiology.

[8]  Mercer Tt,et al.  Effect of auxiliary air flow on the output characteristics of compressed-air nebulizers. , 1969 .

[9]  S. Clarke,et al.  Therapeutic aerosols 1--physical and practical considerations. , 1983, Thorax.

[10]  J. Fleming,et al.  Particle Size Distribution and Deposition from a Jet Nebuliser: Influence of Humidity and Temperature , 1982 .

[11]  M. Newhouse,et al.  Pulmonary aerosol deposition in chronic bronchitis: intermittent positive pressure breathing versus quiet breathing. , 1977, The American review of respiratory disease.

[12]  Mercer Tt Production of therapeutic aerosols; principles and techniques. , 1981 .

[13]  J. Swarbrick Current concepts in the pharmaceutical sciences: dosage form design and bioavailability , 1973 .

[14]  S. Sorokin,et al.  The Respiratory System , 1983 .

[15]  J. Eisenberg,et al.  INHALED ANTIBIOTICS IN CYSTIC FIBROSIS , 1983, The Lancet.

[16]  M. Hodson,et al.  AEROSOL CARBENICILLIN AND GENTAMICIN TREATMENT OF PSEUDOMONAS AERUGINOSA INFECTION IN PATIENTS WITH CYSTIC FIBROSIS , 1981, The Lancet.

[17]  D. Pavia,et al.  ASSESSMENT OF JET NEBULISERS FOR LUNG AEROSOL THERAPY , 1983, The Lancet.