Enzyme-Labeled Phages Detected by Amperometry: A New Method to Study Inline Virus Retention in Membrane Processes

A new method is presented to characterize the retention dynamics of membrane processes with a new virus surrogate used as a tracer and developed in our laboratory. This virus surrogate is an enzyme-labeled MS2 bacteriophage whose activity can be directly and rapidly detected and quantified by amperometry, which is a sensitive electrochemical technique. In the first step, the amperometric measurement was developed and validated. Microfiltration and ultrafiltration experiments consisting of injecting tracers into the feed and monitoring the tracer presence in permeate (or in retentate) by amperometry, and then validating the use of the tracer and its detection technique in the field of membrane filtration. In particular, global retention experiments demonstrated the ability of this method to differentiate among membrane behaviors and dynamic experiments showed the ability of the method to characterize dynamics of retention in a reproducible way. V V C 2012 American Institute of Chemical Engineers AIChE J, 59: 68–78, 2013

[1]  A. Cornish-Bowden Fundamentals of Enzyme Kinetics , 1979 .

[2]  Allen J. Bard,et al.  Electrochemical Methods: Fundamentals and Applications , 1980 .

[3]  R P Mason,et al.  The horseradish peroxidase-catalyzed oxidation of 3,5,3',5'-tetramethylbenzidine. Free radical and charge-transfer complex intermediates. , 1982, The Journal of biological chemistry.

[4]  H. Zollner,et al.  Handbook of Enzyme Inhibitors , 1989 .

[5]  J. Crowther,et al.  Quantification of whole virus particles (146S) of foot-and-mouth disease virus in the presence of virus subunits (12S), using monoclonal antibodies in a sandwich ELISA. , 1995, Vaccine.

[6]  Giuseppe Palleschi,et al.  3,3′,5,5′-Tetramethylbenzidine as electrochemical substrate for horseradish peroxidase based enzyme immunoassays. A comparative study , 1998 .

[7]  G. Bratbak,et al.  Flow cytometric detection of viruses. , 2000, Journal of virological methods.

[8]  T. N. Shekhovtsova,et al.  Enzymatic determination of phenols using peanut peroxidase. , 2001, Talanta.

[9]  Avner Adin,et al.  Fluorescent dye labeled bacteriophages--a new tracer for the investigation of viral transport in porous media: 1. Introduction and characterization. , 2002, Water research.

[10]  D. W. Smith,et al.  Removal of coliphages in secondary effluent by microfiltration-mechanisms of removal and impact of operating parameters. , 2004, Water research.

[11]  Gengfeng Zheng,et al.  Electrical detection of single viruses. , 2004, Proceedings of the National Academy of Sciences of the United States of America.

[12]  C. Brussaard Optimization of Procedures for Counting Viruses by Flow Cytometry , 2004, Applied and Environmental Microbiology.

[13]  Agustín Costa-García,et al.  Amperometric detection in TMB/HRP-based assays , 2005, Analytical and bioanalytical chemistry.

[14]  R. Hintsche,et al.  Rapid detection of viruses using electrical biochips and anti‐virion sera , 2005, Letters in applied microbiology.

[15]  Ku-Shang Chang,et al.  Application of a flow type quartz crystal microbalance immunosensor for real time determination of cattle bovine ephemeral fever virus in liquid. , 2005, Talanta.

[16]  Robert M. Clark,et al.  Application of nanoscale probes for the evaluation of the integrity of ultrafiltration membranes , 2006 .

[17]  Elizabeth Arkhangelsky,et al.  Effect of transmembrane pressure on rejection of viruses by ultrafiltration membranes , 2008 .

[18]  Y. Matsui,et al.  Comparison of behaviors of two surrogates for pathogenic waterborne viruses, bacteriophages Qbeta and MS2, during the aluminum coagulation process. , 2009, Water research.

[19]  Mark Hernandez,et al.  Fluorescent microspheres as virion surrogates in low-pressure membrane studies , 2009 .

[20]  J. Duval,et al.  Efficiency of MS2 phage and Qβ phage removal by membrane filtration in water treatment: Applicability of real-time RT-PCR method , 2009 .

[21]  Y. Matsui,et al.  Estimation of norovirus removal performance in a coagulation-rapid sand filtration process by using recombinant norovirus VLPs. , 2010, Water research.

[22]  Mano Sivaganesan,et al.  Improved strategies and optimization of calibration models for real-time PCR absolute quantification. , 2010, Water research.

[23]  H Guo,et al.  Low-pressure membrane integrity tests for drinking water treatment: A review. , 2010, Water research.

[24]  A new biosynthetic tracer for the inline measurement of virus retention in membrane processes: part II. Biochemical and physicochemical characterizations of the new tracer. , 2011, Analytica chimica acta.

[25]  S. Alfenore,et al.  A new biosynthetic tracer for the inline measurement of virus retention in membrane processes: part I--Synthesis protocol. , 2011, Analytica chimica acta.