Corneal dioptric power after penetrating keratoplasty.

The dioptric power of the cornea (spherical equivalent) was studied in 60 eyes operated on for penetrating keratoplasty. In order to determine the possible influence of (1) the underlying pathology, (2) the presence of neovascularisation, or (3) the size of the graft the sample was divided into four groups, with the following results: group A (keratoconus, same-sized graft) = 42.25 D; group B (keratoconus, oversized graft) = 45.16 D; group C (keratopathy with minimal or no vascularisation) = 45.34 D; group D (keratopathy with significant vascularisation) = 45.36 D. The results showed that donor-receptor disparity is the main factor determining the outcome of the postoperative corneal spherical power. There was no demonstrable influence from underlying pathology or the presence of vessels in the receptor cornea.

[1]  M. Lemp,et al.  Corneal Surgery: Theory, Technique and Tissue , 1989 .

[2]  M. Rubin,et al.  Refraction problems after refractive surgery. , 1988, Survey of ophthalmology.

[3]  D. Musch,et al.  The effect of removing running sutures on astigmatism after penetrating keratoplasty. , 1988, Archives of ophthalmology.

[4]  D. Musch,et al.  Prospective evaluation of a regression-determined formula for use in triple procedure surgery. , 1988, Ophthalmology.

[5]  G. Foulks,et al.  Oversize donor buttons in corneal transplantation surgery for keratoconus. , 1987, Ophthalmic surgery.

[6]  Binder Ps Refractive errors encountered with the triple procedure. , 1987 .

[7]  A. Sugar,et al.  Posterior chamber IOL implantation during keratoplasty for aphakic or pseudophakic corneal edema. , 1987, Cornea.

[8]  P. Binder Refractive errors encountered with the triple procedure. , 1987, Transactions of the New Orleans Academy of Ophthalmology.

[9]  C. Swinger Postoperative astigmatism. , 1987, Survey of ophthalmology.

[10]  F. Brightbill Corneal Surgery: Theory, Technique and Tissue , 1986 .

[11]  R. D. Stulting,et al.  The triple procedure. Analysis of outcome, refraction, and intraocular lens power calculation. , 1986, Ophthalmology.

[12]  J L Keltner,et al.  Comparative material on automated and semiautomated perimeters--1986. , 1981, Ophthalmology.

[13]  D. Musch,et al.  Oversized donor grafts in penetrating keratoplasty. A randomized trial. , 1985, Archives of ophthalmology.

[14]  R. Forster,et al.  Intraocular lens calculation in combined penetrating keratoplasty, cataract extraction and intraocular lens implantation. , 1985, Ophthalmology.

[15]  Maltzman Ba,et al.  Posterior chamber implants and post-operative refractive astigmatism. , 1983 .

[16]  B. Maltzman,et al.  Posterior chamber implants and post-operative refractive astigmatism. , 1983, The CLAO journal : official publication of the Contact Lens Association of Ophthalmologists, Inc.

[17]  W. Bourne,et al.  The effects of oversize donor buttons on postoperative intraocular pressure and corneal curvature in aphakic penetrating keratoplasty. , 1982, Ophthalmology.

[18]  R. Olson Corneal curvature changes associated with penetrating keratoplasty: a mathematical model. , 1980, Ophthalmic surgery.

[19]  R. D. Binkhorst Intraocular Lens Power , 1979, International ophthalmology clinics.

[20]  Binkhorst Cd Intraocular lens power. , 1976 .