Shading correction assisted iterative cone-beam CT reconstruction

Recent advances in total variation (TV) technology enable accurate CT image reconstruction from highly under-sampled and noisy projection data. The standard iterative reconstruction algorithms, which work well in conventional CT imaging, fail to perform as expected in cone beam CT (CBCT) applications, wherein the non-ideal physics issues, including scatter and beam hardening, are more severe. These physics issues result in large areas of shading artifacts and cause deterioration to the piecewise constant property assumed in reconstructed images. To overcome this obstacle, we incorporate a shading correction scheme into low-dose CBCT reconstruction and propose a clinically acceptable and stable three-dimensional iterative reconstruction method that is referred to as the shading correction assisted iterative reconstruction. In the proposed method, we modify the TV regularization term by adding a shading compensation image to the reconstructed image to compensate for the shading artifacts while leaving the data fidelity term intact. This compensation image is generated empirically, using image segmentation and low-pass filtering, and updated in the iterative process whenever necessary. When the compensation image is determined, the objective function is minimized using the fast iterative shrinkage-thresholding algorithm accelerated on a graphic processing unit. The proposed method is evaluated using CBCT projection data of the Catphan© 600 phantom and two pelvis patients. Compared with the iterative reconstruction without shading correction, the proposed method reduces the overall CT number error from around 200 HU to be around 25 HU and increases the spatial uniformity by a factor of 20 percent, given the same number of sparsely sampled projections. A clinically acceptable and stable iterative reconstruction algorithm for CBCT is proposed in this paper. Differing from the existing algorithms, this algorithm incorporates a shading correction scheme into the low-dose CBCT reconstruction and achieves more stable optimization path and more clinically acceptable reconstructed image. The method proposed by us does not rely on prior information and thus is practically attractive to the applications of low-dose CBCT imaging in the clinic.

[1]  H. H. Madden Comments on the Savitzky-Golay convolution method for least-squares-fit smoothing and differentiation of digital data , 1976 .

[2]  B. Bjärngard,et al.  Correction for beam hardening in computed tomography. , 1978, Medical physics.

[3]  P. Joseph,et al.  A Method for Correcting Bone Induced Artifacts in Computed Tomography Scanners , 1978, Journal of computer assisted tomography.

[4]  Gary H. Glover,et al.  Compton scatter effects in CT reconstructions , 1982 .

[5]  A. Coleman,et al.  A beam-hardening correction using dual-energy computed tomography. , 1985, Physics in medicine and biology.

[6]  U Neitzel,et al.  Grids or air gaps for scatter reduction in digital radiography: a model calculation. , 1992, Medical physics.

[7]  D. Yan,et al.  Adaptive radiation therapy , 1997, Physics in medicine and biology.

[8]  J. Hsieh,et al.  An iterative approach to the beam hardening correction in cone beam CT. , 2000, Medical physics.

[9]  Joseph A. O'Sullivan,et al.  Prospects for quantitative CT imaging in the presence of foreign metal bodies using statistical image reconstruction , 2002, Proceedings IEEE International Symposium on Biomedical Imaging.

[10]  Ross T. Whitaker,et al.  GIST: an interactive, GPU-based level set segmentation tool for 3D medical images , 2004, Medical Image Anal..

[11]  Ruola Ning,et al.  X-ray scatter correction algorithm for cone beam CT imaging. , 2004, Medical physics.

[12]  Matthias Bertram,et al.  Performance of standard fluoroscopy antiscatter grids in flat-detector-based cone-beam CT , 2004, SPIE Medical Imaging.

[13]  S. Richard,et al.  A simple, direct method for x-ray scatter estimation and correction in digital radiography and cone-beam CT. , 2005, Medical physics.

[14]  Lei Xing,et al.  Formulating adaptive radiation therapy (ART) treatment planning into a closed-loop control framework , 2007, Physics in medicine and biology.

[15]  Steve B. Jiang,et al.  The management of imaging dose during image-guided radiotherapy: report of the AAPM Task Group 75. , 2007, Medical physics.

[16]  Lingyun Chen,et al.  Visibility of microcalcification in cone beam breast CT: effects of X-ray tube voltage and radiation dose. , 2007, Medical physics.

[17]  Alessandro Foi,et al.  Image Denoising by Sparse 3-D Transform-Domain Collaborative Filtering , 2007, IEEE Transactions on Image Processing.

[18]  Lei Xing,et al.  Evaluation of on-board kV cone beam CT (CBCT)-based dose calculation , 2007, Physics in medicine and biology.

[19]  D. Brenner,et al.  Computed tomography--an increasing source of radiation exposure. , 2007, The New England journal of medicine.

[20]  Nelson Lam,et al.  Radiation dose from cone beam computed tomography for image-guided radiation therapy. , 2008, International journal of radiation oncology, biology, physics.

[21]  T. Marchant,et al.  Shading correction algorithm for improvement of cone-beam CT images in radiotherapy , 2008, Physics in medicine and biology.

[22]  E. Sidky,et al.  Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization , 2008, Physics in medicine and biology.

[23]  Marc Teboulle,et al.  A Fast Iterative Shrinkage-Thresholding Algorithm for Linear Inverse Problems , 2009, SIAM J. Imaging Sci..

[24]  Boyd McCurdy,et al.  Cone beam computerized tomography: the effect of calibration of the Hounsfield unit number to electron density on dose calculation accuracy for adaptive radiation therapy , 2009, Physics in medicine and biology.

[25]  Fang-Fang Yin,et al.  Refinement of treatment setup and target localization accuracy using three-dimensional cone-beam computed tomography for stereotactic body radiotherapy. , 2009, International journal of radiation oncology, biology, physics.

[26]  Lei Zhu,et al.  Shading correction for on-board cone-beam CT in radiation therapy using planning MDCT images. , 2010, Medical physics.

[27]  N. R. Bennett,et al.  Scatter correction method for x-ray CT using primary modulation: phantom studies. , 2010, Medical physics.

[28]  Steve B. Jiang,et al.  GPU-based fast cone beam CT reconstruction from undersampled and noisy projection data via total variation , 2010 .

[29]  Marc Kachelrieß,et al.  Empirical beam hardening correction (EBHC) for CT. , 2010, Medical physics.

[30]  Lei Zhu,et al.  Scatter correction for full-fan volumetric CT using a stationary beam blocker in a single full scan. , 2011, Medical physics.

[31]  Richard Pötter,et al.  Feasibility of CBCT-based target and normal structure delineation in prostate cancer radiotherapy: multi-observer and image multi-modality study. , 2011, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[32]  Xiang Li,et al.  A novel image-domain-based cone-beam computed tomography enhancement algorithm. , 2011, Physics in medicine and biology.

[33]  Steve B. Jiang,et al.  GPU-based iterative cone-beam CT reconstruction using tight frame regularization , 2010, Physics in medicine and biology.

[34]  Brian Nett,et al.  Prior image constrained scatter correction in cone-beam computed tomography image-guided radiation therapy , 2011, Physics in medicine and biology.

[35]  Hao Gao Fast parallel algorithms for the x-ray transform and its adjoint. , 2012, Medical physics.

[36]  Ehsan Samei,et al.  Towards task-based assessment of CT performance: System and object MTF across different reconstruction algorithms. , 2012, Medical physics.

[37]  Lei Zhu,et al.  Accelerated barrier optimization compressed sensing (ABOCS) reconstruction for cone-beam CT: Phantom studies. , 2012, Medical physics.

[38]  Lei Xing,et al.  Improved compressed sensing-based cone-beam CT reconstruction using adaptive prior image constraints , 2012, Physics in medicine and biology.

[39]  M. Osanai,et al.  Photon starvation artifacts of X-ray CT: their true cause and a solution , 2012, Radiological Physics and Technology.

[40]  Xiao Han,et al.  Optimization-based image reconstruction from sparse-view data in offset-detector CBCT. , 2013, Physics in medicine and biology.

[41]  Xun Jia,et al.  Joint CT/CBCT deformable registration and CBCT enhancement for cancer radiotherapy , 2013, Medical Image Anal..

[42]  Bin Wang,et al.  GPU Accelerated Edge-Region Based Level Set Evolution Constrained by 2D Gray-Scale Histogram , 2013, IEEE Transactions on Image Processing.

[43]  Luo Ouyang,et al.  A moving blocker system for cone-beam computed tomography scatter correction. , 2013, Medical physics.

[44]  L Zhu,et al.  TU-F-18A-02: Iterative Image-Domain Decomposition for Dual-Energy CT. , 2014, Medical physics.

[45]  Xiangzhi Bai,et al.  Improved C-arm cardiac cone beam CT based on alternate reconstruction and segmentation , 2014, Biomed. Signal Process. Control..

[46]  Lei Zhu,et al.  Iterative image-domain decomposition for dual-energy CT. , 2014, Medical physics.

[47]  Xiaojing Ye,et al.  Accelerated barrier optimization compressed sensing (ABOCS) for CT reconstruction with improved convergence. , 2014, Physics in medicine and biology.

[48]  Wei Zhao,et al.  Patient-specific scatter correction for flat-panel detector-based cone-beam CT imaging , 2015, Physics in medicine and biology.

[49]  Zdenka Kuncic,et al.  Improving thoracic four-dimensional cone-beam CT reconstruction with anatomical-adaptive image regularization (AAIR). , 2015, Physics in medicine and biology.

[50]  T. Niu,et al.  Iterative CT shading correction with no prior information , 2015, Physics in medicine and biology.

[51]  Hao Yan,et al.  A practical cone-beam CT scatter correction method with optimized Monte Carlo simulations for image-guided radiation therapy , 2015, Physics in medicine and biology.

[52]  Guang-Hong Chen,et al.  Synchronized multiartifact reduction with tomographic reconstruction (SMART-RECON): A statistical model based iterative image reconstruction method to eliminate limited-view artifacts and to mitigate the temporal-average artifacts in time-resolved CT. , 2015, Medical physics.

[53]  Xiaochuan Pan,et al.  Algorithm-enabled exploration of image-quality potential of cone-beam CT in image-guided radiation therapy , 2015, Physics in medicine and biology.

[54]  Wei Zhao,et al.  An indirect transmission measurement-based spectrum estimation method for computed tomography , 2015, Physics in medicine and biology.

[55]  Joseph A. O'Sullivan,et al.  Line Integral Alternating Minimization Algorithm for Dual-Energy X-Ray CT Image Reconstruction , 2016, IEEE Transactions on Medical Imaging.