Multileaf collimator leaf sequencing algorithm for intensity modulated beams with multiple static segments.

The "stop and shoot" method of producing intensity modulation using combinations of static multileaf collimator (MLC) segments has a number of advantages including precise dose delivery, easy verification, and general availability. However, due to the potential limitation of prolonged treatment time, it is essential to keep the number of required segments to a reasonable number. We propose an algorithm to minimize the number of segments for an intensity modulated field. In this algorithm, the sequence of delivery intensity is proposed to be a series of powers of 2, depending on the maximum intensity level in the matrix. The MLC leaf position sequence is designed directly on the two-dimensional intensity matrix to irradiate the largest possible area in each segment. The algorithm can be applied directly to MLC systems with different motion constraints. This algorithm has been evaluated by generating 1000 random 15 x 15 cm intensity matrices, each having from 3 to 16 intensity levels. Five clinical intensity modulated fields generated from the NOMOS CORVUS planning system for a complex clinical head and neck case were also tested with this and two other algorithms. The results of both the statistical and clinical studies showed that for all the intensity matrices tested, the proposed algorithm results in the smallest number of segments with a moderately increased monitor units. Thus it is well-suited for use in static MLC intensity modulation beam delivery. For MLC systems with interleaf motion constraint, we prove mathematically that this constraint reduces the tongue and groove effect at the expense of an increase of 25% in the number of segments.

[1]  E. Hall,et al.  The use of metal compensators to correct for tissue heterogeneity in radiotherapy with high energy radiation beams. , 1962, The British journal of radiology.

[2]  A Brahme,et al.  Shaping of arbitrary dose distributions by dynamic multileaf collimation. , 1988, Physics in medicine and biology.

[3]  D. Convery,et al.  The generation of intensity-modulated fields for conformal radiotherapy by dynamic collimation , 1992 .

[4]  J M Galvin,et al.  Combining multileaf fields to modulate fluence distributions. , 1993, International journal of radiation oncology, biology, physics.

[5]  S. Spirou,et al.  Generation of arbitrary intensity profiles by dynamic jaws or multileaf collimators. , 1994, Medical physics.

[6]  T. Bortfeld,et al.  X-ray field compensation with multileaf collimators. , 1994, International journal of radiation oncology, biology, physics.

[7]  S. Spirou,et al.  Dose calculation for photon beams with intensity modulation generated by dynamic jaw or multileaf collimations. , 1994, Medical physics.

[8]  W Schlegel,et al.  Dynamic X-ray compensation for conformal radiotherapy by means of multi-leaf collimation. , 1994, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[9]  T. Bortfeld,et al.  Realization and verification of three-dimensional conformal radiotherapy with modulated fields. , 1994, International journal of radiation oncology, biology, physics.

[10]  Implementation of a three-dimensional compensation system based on computed tomography generated surface contours and tissue inhomogeneities. , 1994, Medical physics.

[11]  R Svensson,et al.  Simultaneous optimization of dynamic multileaf collimation and scanning patterns or compensation filters using a generalized pencil beam algorithm. , 1995, Medical physics.

[12]  C. Yu,et al.  A method for implementing dynamic photon beam intensity modulation using independent jaws and a multileaf collimator. , 1995, Physics in medicine and biology.

[13]  A L Boyer,et al.  Use of a multileaf collimator as a dynamic missing-tissue compensator. , 1996, Medical physics.

[14]  R Mohan,et al.  Conformal radiation treatment of prostate cancer using inversely-planned intensity-modulated photon beams produced with dynamic multileaf collimation. , 1996, International journal of radiation oncology, biology, physics.

[15]  J. V. van Santvoort,et al.  Dynamic multileaf collimation without 'tongue-and-groove' underdosage effects. , 1996, Physics in medicine and biology.

[16]  T LoSasso,et al.  Dosimetric verification of intensity-modulated fields. , 1996, Medical physics.