Blood flow velocity profiles in the aortic annulus: a 3-dimensional freehand color flow Doppler imaging study.

BACKGROUND The use of a single sample volume in Doppler measurements of the velocity time integral (VTI) in the aortic annulus may introduce errors in calculations of stroke volumes, shunts, regurgitant fractions, and aortic valve area. To study the blood flow velocity distribution and assess this potential error, we used a dynamic 3-dimensional color flow Doppler imaging method. METHODS AND RESULTS Seventeen healthy volunteers were studied. The ultrasound data were captured from 10 to 20 heartbeats at a high frame rate (mean 57 frames per second) while freely tilting the transducer in the apical position. A magnetic position-sensor system recorded the spatial position and orientation of the probe. The raw digital ultrasound data were analyzed off-line with no loss of temporal resolution. Blood flow velocities were integrated across a spherical surface that tracked the aortic annulus during systole. The ratios of the systolic maximum to the systolic mean VTI ranged from 1.2 to 1.5 (mean 1.4). At the time of systolic peak flow, the ratios of the maximum to the mean velocity ranged from 1.1 to 2.0 (mean 1.5). The location of the maximum velocities and VTI showed individual variation. CONCLUSION The blood flow velocity profile was nonuniform. By using a single sample volume in Doppler measurements of the VTI in the aortic annulus, errors ranging from 20% to 50% may be introduced in calculations of stroke volumes.

[1]  E. M. Pedersen,et al.  Heart motion-adapted MR velocity mapping of blood velocity distribution downstream of aortic valve prostheses: initial experience. , 2001, Radiology.

[2]  H. Torp,et al.  Measurement of volumetric mitral and aortic blood flow based on a new freehand three-dimensional colour flow imaging method. An in vivo validation. , 2000, European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology.

[3]  H. Torp,et al.  Volumetric blood flow measurement with the use of dynamic 3-dimensional ultrasound color flow imaging. , 2000, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[4]  E Steen,et al.  Dynamic three-dimensional freehand echocardiography using raw digital ultrasound data. , 1999, Ultrasound in medicine & biology.

[5]  T Irvine,et al.  Three-dimensional reconstruction of the color Doppler-imaged vena contracta for quantifying aortic regurgitation: studies in a chronic animal model. , 1999, Circulation.

[6]  P K Paulsen,et al.  New semiautomated Doppler method for quantification of volumetric flow: intraoperative validation with multiplane transesophageal color Doppler imaging. , 1997, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[7]  K Matre,et al.  Three-dimensional cross-sectional velocity distribution in the ascending aorta in cardiac patients. , 1996, Clinical physiology.

[8]  V. Poutanen,et al.  Cross sectional profiles of systolic flow velocities in left ventricular outflow tract of normal subjects. , 1995, British heart journal.

[9]  M. Kupari,et al.  Systolic flow velocity profile in the left ventricular outflow tract in persons free of heart disease. , 1993, The American journal of cardiology.

[10]  K. Matre,et al.  Velocity distributions in the left ventricular outflow tract and the aortic anulus measured with Doppler colour flow mapping in normal subjects. , 1993, European heart journal.

[11]  H. Torp,et al.  Cross-sectional left ventricular outflow tract velocities before and after aortic valve replacement: a comparative study with two-dimensional Doppler ultrasound. , 1993, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[12]  R. Mohiaddin,et al.  Magnetic resonance imaging: a method for the assessment of changes in vascular structure and function. , 1991, Journal of human hypertension.

[13]  H. Torp,et al.  The velocity distribution in the aortic anulus in normal subjects: a quantitative analysis of two-dimensional Doppler flow maps. , 1991, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[14]  D N Firmin,et al.  Blood flow patterns in the human aorta studied by magnetic resonance. , 1987, British heart journal.

[15]  K. Matre,et al.  Blood velocity distribution in the human ascending aorta. , 1987, Circulation.

[16]  L. Hatle,et al.  Noninvasive estimation of valve area in patients with aortic stenosis by Doppler ultrasound and two-dimensional echocardiography. , 1985, Circulation.

[17]  J. Tanouchi,et al.  A new approach to noninvasive evaluation of aortic regurgitant fraction by two-dimensional Doppler echocardiography. , 1985, Circulation.

[18]  M C Limacher,et al.  Pulsed Doppler echocardiographic determination of stroke volume and cardiac output: clinical validation of two new methods using the apical window. , 1984, Circulation.

[19]  P. Peronneau,et al.  Flow in the thoracic aorta. , 1979, Cardiovascular research.

[20]  Odd Helge Gilja,et al.  PIO 7501 3D processing of ultrasound images using a novel echopac-3D® software , 1997 .

[21]  W. Kim,et al.  A new Doppler method for quantification of volumetric flow: in vivo validation using color Doppler. , 1996, Journal of the American College of Cardiology.

[22]  M. Hori,et al.  Noninvasive evaluation of the ratio of pulmonary to systemic flow in atrial septal defect by duplex Doppler echocardiography. , 1984, Circulation.

[23]  P K Paulsen,et al.  Three-dimensional visualization of velocity profiles in the ascending aorta in dogs, measured with a hot-film anemometer. , 1983, Journal of biomechanics.