Rapid islanding detection using multi-level inverter for grid-interactive PV system

Abstract A novel reference signal generator is combined with a multi-level inverter to form a rapid islanding detection scheme for grid-interactive PV system. The reference signal generator can easily be synchronized with the utility grid signal and produced a fixed magnitude and very low total harmonic distortion (THD) sinusoidal signal which is in phase with the utility grid signal. Unlike conventional phase-locked loop (PLL) circuitry, the reference signal generator can also provide a fixed magnitude sinusoidal signal even if the utility grid is disconnected and automatically re-synchronous with the grid rapidly. Consequently, seamless transfer between grid-connected and stand-alone modes could easily be achieved if anti-islanding protection is not required. If a saturation element is applied to the raw reference signal followed by the synthesis of the truncated signal using a multi-level inverter, the distinct flat-top feature of the synthesized signal can quickly and easily be identified if the network is in islanding mode at the point of common coupling. Experimental results are included to demonstrate the effectiveness of the proposed detection scheme.

[1]  Dehong Xu,et al.  An Improved Islanding Detection Method for a Grid-Connected Inverter With Intermittent Bilateral Reactive Power Variation , 2013, IEEE Transactions on Power Electronics.

[2]  Bin Wu,et al.  Improved Active Frequency Drift Anti-islanding Detection Method for Grid Connected Photovoltaic Systems , 2012, IEEE Transactions on Power Electronics.

[3]  Frede Blaabjerg,et al.  Accurate and Less-Disturbing Active Antiislanding Method Based on PLL for Grid-Connected Converters , 2010, IEEE Transactions on Power Electronics.

[4]  Ahmad B. Rad,et al.  Auto-tuning of output predictive PI controller , 1999 .

[5]  K M Tsang,et al.  Autotuning positive feedback time delay controller for dead time processes. , 2002, ISA transactions.

[6]  J. Rocabert,et al.  Intelligent Connection Agent for Three-Phase Grid-Connected Microgrids , 2011, IEEE Transactions on Power Electronics.

[7]  K. M. Tsang,et al.  27-Level DC–AC inverter with single energy source , 2012 .

[8]  K. M. Tsang,et al.  Three-level grid-connected photovoltaic inverter with maximum power point tracking , 2013 .

[9]  Ebrahim Babaei,et al.  New cascaded multilevel inverter topology with minimum number of switches , 2009 .

[10]  Gabriel Garcera,et al.  An Active Anti-Islanding Method Based on Phase-PLL Perturbation , 2011, IEEE Transactions on Power Electronics.

[11]  Alexis B. Rey-Boué,et al.  An integrative approach to the design methodology for 3-phase power conditioners in Photovoltaic Grid-Connected systems , 2012 .

[12]  Y. Sozer,et al.  Modeling and Control of Utility Interactive Inverters , 2009, IEEE Transactions on Power Electronics.