X-ray CT high-density artefact suppression in cryosurgery.

Advantages of x-ray CT for imaging guidance of cryosurgery include 3D visualization of frozen and unfrozen tissue and calibration of temperature in the tissue water-ice interface (0-10 degrees C) to Hounsfield units. However, use of x-ray CT images and their thermal calibration can be compromised by the cryoprobes generating high-density streak artefacts. A new subtraction technique for artefact suppression is proposed and tested in prostate cryosurgery simulations. By subtracting the measured CT x-ray projection profile without cryoprobes from the profile with cryoprobes plus iceballs, one obtains the combined profile of the cryoprobes and a low value background. Polynomial interpolation to obtain the background profile allows its addition to the original profile without probes. The result may then be fed to a conventional filtered back-projection routine to reconstruct the probe-free image. Finally the cryoprobe pixels in the originally constructed image with probes and iceballs are added back to the probe-free image to get the final artefact-suppressed image. The major advantage of this subtraction technique is that it can successfully suppress the high-density artefacts in bone-abundant body regions such as the pelvis. X-ray CT images of cryoprobe arrays in a homogeneous gelatin phantom and the pelvic region of an anthropomorphic Rando phantom containing a human skeleton were generated. After suppression, cryoprobe metal artefact streaks are reduced and visualization of the positions and dimensions of the cryoprobes are well preserved.

[1]  G. Herman Correction for beam hardening in computed tomography. , 1979, Physics in medicine and biology.

[2]  Gary H. Glover,et al.  An algorithm for the reduction of metal clip artifacts in CT reconstructions. , 1981 .

[3]  C R Crawford,et al.  Reprojection using a parallel backprojector. , 1986, Medical physics.

[4]  W. Kalender,et al.  Reduction of CT artifacts caused by metallic implants. , 1987 .

[5]  I. Lax,et al.  Stereotactic radiotherapy of malignancies in the abdomen. Methodological aspects. , 1994, Acta oncologica.

[6]  Joseph A. O'Sullivan,et al.  Iterative deblurring for CT metal artifact reduction , 1996, IEEE Trans. Medical Imaging.

[7]  G. Sandison,et al.  X-ray CT monitoring of iceball growth and thermal distribution during cryosurgery. , 1998, Physics in medicine and biology.

[8]  S. Zhao,et al.  X-ray CT metal artifact reduction using wavelets: an application for imaging total hip prostheses , 2000, IEEE Transactions on Medical Imaging.

[9]  G. Sandison,et al.  Suppression of high-density artefacts in X-ray CT images using temporal digital subtraction with application to cryotherapy , 2000 .

[10]  Patrick Dupont,et al.  An iterative maximum-likelihood polychromatic algorithm for CT , 2001, IEEE Transactions on Medical Imaging.

[11]  Laigao Michael Chen,et al.  Novel method for reducing high-attenuation object artifacts in CT reconstructions , 2002, SPIE Medical Imaging.

[12]  H. Tuy A post-processing algorithm to reduce metallic clip artifacts in CT images , 1993, European Radiology.