INTRODUCTION
Pulmonary hypoplasia is a condition of the newborn that is characterized by underdeveloped lungs and poor outcome. One strategy in the treatment of patients with hypoplasia is to augment underdeveloped lungs using biocompatible artificial lung tissue. However, one central challenge in current pulmonary tissue engineering efforts remains the development of a stable bio-mimetic alveolar-capillary membrane. Accordingly, we have built a series of bio-mimetic microfluidic devices that specifically model the alveolar-capillary membrane. Current designs include a single-layer microchip that exposes alveolar and endothelial cell types to controlled fluidic stimuli. A more advanced multi-layered device allows for alveolar cells to be cultured at an air interface while allowing constant media nourishment and waste removal, thus better mimicking the physiologic milieu of the alveolar-capillary interface. Both devices possess the benefit of parallel testing.
MATERIAL AND METHODS
Microdevices were fabricated using soft lithography in a biocompatible transparent polymeric material, polydimethyl siloxane, sealed covalently to glass. The multistage microdevice also integrated a suspended polyethylene terephthalate membrane connected via microfluidic channels to constant media and air access. Pulmonary endothelial (HMEC-1) and alveolar epithelial (A549) cell lines, along with fetal pulmonary cells (FPC) harvested from Swiss Webster mice at day 18 gestational age, were studied under multiple hydrodynamic shear conditions and liquid-to-cell ratio regimes. Cultures were examined for cell viability, function and proliferation to confluent monolayers. A549 cells cultured at an air-interface in a microdevice was also tested for their ability to maintain cell phenotype and function.
RESULTS
The single-layer differential flow microdevice allowed for a systematic determination of the optimal growth conditions of various lung-specific cell types in a microfluidic environment. Our device showed a greater surfactant based decrease in surface tension of the alveolar hypophase in A549 cultures exposed to air as compared to submerged cultures.
CONCLUSIONS
We have successfully developed biomimetic microfluidic devices that specifically allow stable alveolar cell growth at the air-liquid interface. This work serves prerequisite towards an implantable artificial alveolar membrane.
[1]
Tza-Huei Wang,et al.
An open-access microfluidic model for lung-specific functional studies at an air-liquid interface
,
2009,
Biomedical microdevices.
[2]
D. Sherer,et al.
Pulmonary hypoplasia: a review.
,
1990,
Obstetrical & gynecological survey.
[3]
D. Alberti,et al.
Retrospective study of 111 cases of congenital diaphragmatic hernia treated with early high-frequency oscillatory ventilation and presurgical stabilization.
,
2007,
Journal of pediatric surgery.
[4]
K. Azarow,et al.
Pulmonary barotrauma in congenital diaphragmatic hernia: a clinicopathological correlation.
,
1999,
Journal of pediatric surgery.
[5]
D. Pierson,et al.
A549 Lung Epithelial Cells Grown as Three-Dimensional Aggregates: Alternative Tissue Culture Model for Pseudomonas aeruginosa Pathogenesis
,
2005,
Infection and Immunity.
[6]
Mengyan Li,et al.
Engineering three-dimensional pulmonary tissue constructs.
,
2006,
Tissue engineering.
[7]
W. Thompson,et al.
Pulmonary microvascular and macrovascular endothelial cells: differential regulation of Ca2+and permeability.
,
1998,
American journal of physiology. Lung cellular and molecular physiology.
[8]
Tza-Huei Wang,et al.
CHARACTERIZATION OF PULMONARY CELL GROWTH PARAMETERS IN A CONTINUOUS PERFUSION MICROFLUIDIC ENVIRONMENT
,
2007,
Experimental lung research.
[9]
J A Clements,et al.
Direct determination of surface tension in the lung.
,
1976,
Proceedings of the National Academy of Sciences of the United States of America.
[10]
M. Pian,et al.
Maintenance of the differentiated type II cell phenotype by culture with an apical air surface.
,
1997,
The American journal of physiology.