On the Feasibility of Assessing Burn Wound Healing without Removal of Dressings Using Radiometric Millimetre-Wave Sensing

The authors present transmission data, taken at Ka (36GHz) and W (95 GHz) bands in the millimetre-wave region of the electromagnetic spectrum, for various dressing materials used in the treatment and management of burn wounds. The results show that such materials are highly transparent (typically > 90% transmission) and, in their dry state, will permit the sensing of the surface of the skin through the thick layers (> 2 cm) of different dressings typically applied in medical treatment of burn wounds. Furthermore, the authors present emissivity data, taken at the same frequency bands, for different regions of human skin on the arm and for samples of chicken flesh with and without skin and before and after localised heat treatment. In vivo human skin has a lower emissivity than chicken flesh samples, 0.3–0.5 compared to 0.6–0.7. However, changes in surface emissivity of chicken samples caused by the short-term application of heat are observable through dressing materials, indicating the feasibility of a millimetre-wave imaging to map changes in tissue emissivity for monitoring the state of burn wounds (and possibly other wounds) non-invasively and without necessitating the removal of the wound dressings.

[1]  Roger Appleby,et al.  Comparison of passive millimeter-wave and IR imagery in a nautical environment , 2009, Defense + Commercial Sensing.

[2]  R. Zoughi,et al.  Near-field microwave and mm-wave noninvasive diagnosis of human skin , 2009, 2009 IEEE International Workshop on Medical Measurements and Applications.

[3]  R. N. Anderton,et al.  Millimeter-Wave and Submillimeter-Wave Imaging for Security and Surveillance , 2007, Proceedings of the IEEE.

[4]  Thomas E. Hall,et al.  Three-dimensional millimeter-wave imaging for concealed weapon detection , 2001 .

[5]  Y. Nikawa,et al.  Novel microwave and millimeter-wave biomedical applications , 1999, 4th International Conference on Telecommunications in Modern Satellite, Cable and Broadcasting Services. TELSIKS'99 (Cat. No.99EX365).

[6]  Barry D. Van Veen,et al.  Development of Anatomically Realistic Numerical Breast Phantoms With Accurate Dielectric Properties for Modeling Microwave Interactions With the Human Breast , 2008, IEEE Transactions on Biomedical Engineering.

[7]  Analysis of human skin tissue by millimeter‐wave reflectometry , 2013, Skin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging.

[8]  Antao Chen,et al.  Terahertz reflectometry of burn wounds in a rat model , 2011, Biomedical optics express.

[9]  Dirk Nuessler,et al.  Monitoring of wound healing by millimetre wave imaging , 2010, 35th International Conference on Infrared, Millimeter, and Terahertz Waves.

[10]  Piero Tognolatti,et al.  Microwave radiometry for medical thermal imaging: theory and experiment , 1992, 1992 IEEE Microwave Symposium Digest MTT-S.

[11]  M.C. Kemp,et al.  Millimetre wave and terahertz technology for detection of concealed threats - a review , 2006, 2007 Joint 32nd International Conference on Infrared and Millimeter Waves and the 15th International Conference on Terahertz Electronics.

[12]  James W. Lamb,et al.  Miscellaneous data on materials for millimetre and submillimetre optics , 1996 .

[13]  N. D. Rezgui,et al.  A Review of Nonimaging Stand-Off Concealed Threat Detection with Millimeter-Wave Radar [Application Notes] , 2012, IEEE Microwave Magazine.

[14]  Tadao Nagatsuma,et al.  Latest Trends in Millimeter-wave Imaging Technology , 2008 .

[15]  T. Zwick,et al.  Millimeter-Wave Technology for Automotive Radar Sensors in the 77 GHz Frequency Band , 2012, IEEE Transactions on Microwave Theory and Techniques.

[16]  Nicholas Bowring,et al.  Determination of the complex permittivity of textiles and leather in the 14-40 GHz millimetre-wave band using a free-wave transmittance only method , 2008 .

[17]  M. Dziewoński Planimetry of thermograms in diagnosis of burn wounds , 2009 .

[18]  Rupert N. Anderton,et al.  The design of a real-time 94-GHz passive millimetre-wave imager for helicopter operations , 2004, SPIE Security + Defence.

[19]  J. Wenger Automotive mm-wave radar: status and trends in system design and technology , 1998 .

[20]  J. Federici,et al.  THz imaging and sensing for security applications—explosives, weapons and drugs , 2005 .

[21]  Zhouyue Pi,et al.  An introduction to millimeter-wave mobile broadband systems , 2011, IEEE Communications Magazine.

[22]  S. Alekseev,et al.  Human skin permittivity determined by millimeter wave reflection measurements , 2007, Bioelectromagnetics.

[23]  P. Siegel Terahertz technology in biology and medicine , 2004, 2004 IEEE MTT-S International Microwave Symposium Digest (IEEE Cat. No.04CH37535).

[24]  C. Alabaster The microwave properties of tissue and other lossy dielectrics , 2004 .

[25]  Kamal Sarabandi,et al.  An ultrafast wide-band millimeter-wave (MMW) polarimetric radar for remote sensing applications , 2002, IEEE Trans. Geosci. Remote. Sens..

[26]  F. Bardati,et al.  Radiometric sensing of biological layered media , 1983 .

[27]  Amir Ahmad Shishegar,et al.  Dielectric properties estimation of normal and malignant skin tissues at millimeter-wave frequencies using effective medium theory , 2014, 2014 22nd Iranian Conference on Electrical Engineering (ICEE).