Epiphyseal-based designs for tibial plateau components--II. Stress analysis in the sagittal plane.

A two-dimensional, finite element study was undertaken to establish the stresses in the proximal tibia before and after total knee arthroplasty. Equivalent-thickness models in a sagittal plane were created for the natural, proximal tibia and for the proximal tibia with two different types of tibial plateau components. All components simulated bony ingrowth fixation, i.e. no cement layer existed between component and bone. In addition, the interface between component and bone was assumed to be intimately connected, representing complete bony ingrowth and a rigid state of fixation. Two load cases were considered: a joint reaction force acting in conjunction with a patellar ligament force, simulating the knee at 40 degrees of flexion; and a joint reaction force directed along the long axis of the tibia. For the natural tibia model, the pattern of principal stresses for loadcase 1 more closely corresponds to the epiphyseal plate geometry and trabecular morphology than do the principal stress patterns for loadcase 2. Judging from the distribution of principal stresses, loadcase 1 represents a more severe test of implant design than does loadcase 2. The model of the component with a peg predicted that the trabecular bone near the tip of the peg will experience higher than normal stresses, while the bone stresses near the posterior aspect adjacent to the metal tray will be reduced. A component without pegs that incorporates a posterior chamfer and an anterior lip lead to stress distributions closer to those existing in the natural tibia. The interface geometry for this design is based upon the contour of the epiphyseal plate.

[1]  J L Lewis,et al.  A comparative evaluation of tibial component designs of total knee prostheses. , 1982, The Journal of bone and joint surgery. American volume.

[2]  Smith Jw,et al.  The relationship of epiphysial plates to stress in some bones of the lower limb. , 1962 .

[3]  J. Insall,et al.  Total knee arthroplasty , 2015 .

[4]  A. M. Ahmed,et al.  In-vitro measurement of static pressure distribution in synovial joints--Part I: Tibial surface of the knee. , 1983, Journal of biomechanical engineering.

[5]  R S Laskin,et al.  Unicompartmental tibiofemoral resurfacing arthroplasty. , 1978, The Journal of bone and joint surgery. American volume.

[6]  P G Maquet,et al.  Femorotibial weight-bearing areas. Experimental determination. , 1975, The Journal of bone and joint surgery. American volume.

[7]  A E Engin,et al.  Biomechanics of normal and abnormal knee joint. , 1974, Journal of biomechanics.

[8]  C. Ranawat,et al.  A comparison of four models of total knee-replacement prostheses. , 1976, The Journal of bone and joint surgery. American volume.

[9]  G. Smidt Biomechanical analysis of knee flexion and extension. , 1973, Journal of biomechanics.

[10]  Smith Jw,et al.  The structure and stress relations of fibrous epiphysial plates. , 1962 .

[11]  M. B. Coventry Geometric total knee arthroplasty , 1973 .

[12]  W C Hayes,et al.  Axisymmetric finite element analysis of the lateral tibial plateau. , 1978, Journal of biomechanics.

[13]  D R Carter,et al.  Stress changes in the femoral head due to porous ingrowth surface replacement arthroplasty. , 1984, Journal of biomechanics.

[14]  R. Grimer,et al.  The long-term results of Stanmore total knee replacements. , 1984, The Journal of bone and joint surgery. British volume.

[15]  J. Goodfellow,et al.  The radiolucent line beneath the tibial components of the Oxford meniscal knee. , 1984, The Journal of bone and joint surgery. British volume.

[16]  P. Walker,et al.  Fixation of tibial components of knee prostheses. , 1981, The Journal of bone and joint surgery. American volume.

[17]  W. Hayes,et al.  The compressive behavior of bone as a two-phase porous structure. , 1977, The Journal of bone and joint surgery. American volume.

[18]  E Y Chao,et al.  A survey of finite element analysis in orthopedic biomechanics: the first decade. , 1983, Journal of biomechanics.

[19]  D R Carter,et al.  Stress distributions in the acetabular region--I. Before and after total joint replacement. , 1982, Journal of biomechanics.

[20]  L. S. Matthews,et al.  The mechanical properties of human tibial trabecular bone as a function of metaphyseal location. , 1983, Journal of biomechanics.

[21]  J L Lewis,et al.  Analysis of model variables and fixation post length effects on stresses around a prosthesis in the proximal tibia. , 1981, Journal of biomechanical engineering.

[22]  M. B. Coventry Two-part total knee arthroplasty: evolution and present status. , 1979, Clinical orthopaedics and related research.

[23]  D. Kettelkamp,et al.  Tibiofemoral contact area--determination and implications. , 1972, The Journal of bone and joint surgery. American volume.

[24]  J B Morrison,et al.  The mechanics of the knee joint in relation to normal walking. , 1970, Journal of biomechanics.

[25]  D L Bartel,et al.  Performance of the tibial component in total knee replacement. , 1982, The Journal of bone and joint surgery. American volume.

[26]  A. Burstein,et al.  Epiphyseal-plate cartilage. A biomechanical and histological analysis of failure modes. , 1974, The Journal of bone and joint surgery. American volume.

[27]  E. Rybicki,et al.  On the mathematical analysis of stress in the human femur. , 1972, Journal of biomechanics.

[28]  Bryan Rs,et al.  Polycentric total knee arthroplasty. , 1973 .

[29]  W. Waugh,et al.  Estimating the survival time of knee replacement. , 1982, The Journal of bone and joint surgery. British volume.

[30]  C O Bechtol The biomechanics of the epiphyseal lines as a guide to design considerations for the attachment of prosthesis to the musculo-skeletal system. , 1973, Journal of biomedical materials research.

[31]  P Ducheyne,et al.  Failure of total knee arthroplasty due to loosening and deformation of the tibial component. , 1978, The Journal of bone and joint surgery. American volume.

[32]  L. Riley Total knee arthroplasty. , 1985, Clinical orthopaedics and related research.

[33]  D R Pedersen,et al.  An analysis of tibial component design in total knee arthroplasty. , 1983, Journal of biomechanics.

[34]  P. Walker,et al.  Fixation of the tibial components of condylar replacement knee prostheses. , 1976, Journal of biomechanics.

[35]  M. B. Coventry,et al.  Geometric total knee arthroplasty. A two-year follow-up study. , 1976, The Journal of bone and joint surgery. American volume.