Automated IMT estimation and BMI correlation using a low-quality carotid ultrasound image database from India

This paper presents AtheroEdgeLowRes (AELR), an extention of AtheroEdge™ from AtheroPoint™, and a solution to carotid ultrasound IMT measurement in low-resolution and overall low quality images. The images were collected using a low-end ultrasound machine during a screening study in India. We aim to demonstrate the accuracy and reproducibility of the AELR system by benchmarking it against an expert Reader's manual tracing and to show the correlation between the automatically measured intima media thickness (IMT) and the subjects' cardiovascular risk factors (i.e. body mass index - BMI). We introduced an innovative penalty function (PF) to our dual-snake segmentation technique, necessary due to the low image resolution. We processed 512 images from 256 patients, and correlated the AELR IMT values with the patients' age and BMI. AELR processed all 512 images, and the IMT measurement error was 0.011±0.099 mm with the PF correction and 0.173±0.127 mm without. AELR IMT values correlated with the Reader's values (r = 0.883) and also correlated with the subject's BMI and age. The AELR system showed accuracy and reproducibility levels that make it suitable to be used in large epidemiological and screening studies in emerging countries.

[1]  U. Rajendra Acharya,et al.  Ultrasound IMT measurement on a multi-ethnic and multi-institutional database: Our review and experience using four fully automated and one semi-automated methods , 2012, Comput. Methods Programs Biomed..

[2]  E. Vicaut,et al.  Mannheim Carotid Intima-Media Thickness Consensus (2004–2006) , 2006, Cerebrovascular Diseases.

[3]  J. Leipsic,et al.  The effect of obesity on the association between liver fat and carotid atherosclerosis in a multi-ethnic cohort. , 2013, Atherosclerosis.

[4]  Jasjit S. Suri,et al.  A state of the art review on intima-media thickness (IMT) measurement and wall segmentation techniques for carotid ultrasound , 2010, Comput. Methods Programs Biomed..

[5]  Naqvi Tz Ultrasound vascular screening for cardiovascular risk assessment. Why, when and how? , 2006 .

[6]  Filippo Molinari,et al.  Fully Automated Dual‐Snake Formulation for Carotid Intima‐Media Thickness Measurement , 2012, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[7]  Junaed Sattar Snakes , Shapes and Gradient Vector Flow , 2022 .

[8]  F. Faita,et al.  Real‐time Measurement System for Evaluation of the Carotid Intima‐Media Thickness With a Robust Edge Operator , 2008, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[9]  U Rajendra Acharya,et al.  Automated carotid IMT measurement and its validation in low contrast ultrasound database of 885 patient Indian population epidemiological study: results of AtheroEdge™ Software. , 2012, International angiology : a journal of the International Union of Angiology.

[10]  J. Polak,et al.  Inter‐Reader Differences in Common Carotid Artery Intima‐Media Thickness , 2011, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[11]  J. Suri,et al.  What is the correct distance measurement metric when measuring carotid ultrasound intima-media thickness automatically? , 2012, International angiology : a journal of the International Union of Angiology.

[12]  U. Rajendra Acharya,et al.  Completely Automated Multiresolution Edge Snapper—A New Technique for an Accurate Carotid Ultrasound IMT Measurement: Clinical Validation and Benchmarking on a Multi-Institutional Database , 2012, IEEE Transactions on Image Processing.

[13]  Pierre Amarenco,et al.  Plasma triglyceride levels and risk of stroke and carotid atherosclerosis: a systematic review of the epidemiological studies. , 2009, Atherosclerosis.

[14]  Alejandro Macchia,et al.  CARMELA: assessment of cardiovascular risk in seven Latin American cities. , 2008, The American journal of medicine.