Quantifying 3D Strain in Scaffold Implants for Regenerative Medicine

Regenerative medicine solutions require thoughtful design to elicit the intended biological response. This includes the biomechanical stimulus to generate an appropriate strain in the scaffold and surrounding tissue to drive cell lineage to the desired tissue. To provide appropriate strain on a local level, new generations of scaffolds often involve anisotropic spatially graded mechanical properties that cannot be characterised with traditional materials testing equipment. Volumetric examination is possible with three-dimensional (3D) imaging, in situ loading and digital volume correlation (DVC). Micro-CT and DVC were utilised in this study on two sizes of 3D-printed inorganic/organic hybrid scaffolds (n = 2 and n = 4) with a repeating homogenous structure intended for cartilage regeneration. Deformation was observed with a spatial resolution of under 200 µm whilst maintaining displacement random errors of 0.97 µm, strain systematic errors of 0.17% and strain random errors of 0.031%. Digital image correlation (DIC) provided an analysis of the external surfaces whilst DVC enabled localised strain concentrations to be examined throughout the full 3D volume. Strain values derived using DVC correlated well against manually calculated ground-truth measurements (R2 = 0.98, n = 8). The technique ensures the full 3D micro-mechanical environment experienced by cells is intimately considered, enabling future studies to further examine scaffold designs for regenerative medicine.

[1]  G. Blunn,et al.  Full-Field Strain Uncertainties and Residuals at the Cartilage-Bone Interface in Unstained Tissues Using Propagation-Based Phase-Contrast XCT and Digital Volume Correlation , 2020, Materials.

[2]  Julian R. Jones,et al.  Scaffold channel size influences stem cell differentiation pathway in 3-D printed silica hybrid scaffolds for cartilage regeneration. , 2020, Biomaterials science.

[3]  U. Hansen,et al.  Quantifying deformations and strains in human intervertebral discs using Digital Volume Correlation combined with MRI (DVC-MRI). , 2020, Journal of biomechanics.

[4]  J. Kanczler,et al.  Exploratory Full-Field Strain Analysis of Regenerated Bone Tissue from Osteoinductive Biomaterials , 2020, Materials.

[5]  S. Cartmell,et al.  In situ characterization of nanoscale strains in loaded whole joints via synchrotron X-ray tomography , 2019, Nature Biomedical Engineering.

[6]  K. Reynolds,et al.  Quantification of human bone microarchitecture damage in press-fit femoral knee implantation using HR-pQCT and digital volume correlation. , 2019, Journal of the mechanical behavior of biomedical materials.

[7]  B. Bay,et al.  Synchrotron tomography of intervertebral disc deformation quantified by digital volume correlation reveals microstructural influence on strain patterns. , 2019, Acta biomaterialia.

[8]  Marta Peña Fernández,et al.  Full-Field Strain Analysis of Bone-Biomaterial Systems Produced by the Implantation of Osteoregenerative Biomaterials in an Ovine Model. , 2019, ACS biomaterials science & engineering.

[9]  E. Dall’Ara,et al.  Effect of SR-microCT radiation on the mechanical integrity of trabecular bone using in situ mechanical testing and digital volume correlation. , 2018, Journal of the mechanical behavior of biomedical materials.

[10]  B. Bay,et al.  A review of techniques for visualising soft tissue microstructure deformation and quantifying strain Ex Vivo , 2018, Journal of microscopy.

[11]  Julian R. Jones,et al.  Bouncing and 3D printable hybrids with self-healing properties , 2018 .

[12]  G W Blunn,et al.  Optimization of digital volume correlation computation in SR‐microCT images of trabecular bone and bone‐biomaterial systems , 2018, Journal of microscopy.

[13]  François Hild,et al.  Evaluation of measurement uncertainties of digital volume correlation applied to laminography data , 2018 .

[14]  Bing Pan,et al.  Thermal error analysis and compensation for digital image/volume correlation , 2018 .

[15]  Bing Pan,et al.  Morphological evolution and internal strain mapping of pomelo peel using X-ray computed tomography and digital volume correlation , 2018 .

[16]  Thuy-Tien N. Nguyen,et al.  Microstructural Consequences of Blast Lung Injury Characterized with Digital Volume Correlation , 2017, Front. Mater..

[17]  L. Cristofolini,et al.  Precision of Digital Volume Correlation Approaches for Strain Analysis in Bone Imaged with Micro-Computed Tomography at Different Dimensional Levels , 2017, Front. Mater..

[18]  W. Świȩszkowski,et al.  Investigation of mechanical properties of porous composite scaffolds with tailorable degradation kinetics after in vitro degradation using digital image correlation , 2017 .

[19]  Ulrich N Hansen,et al.  Femoral fracture type can be predicted from femoral structure: A finite element study validated by digital volume correlation experiments , 2017, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[20]  M. Viceconti,et al.  Local displacement and strain uncertainties in different bone types by digital volume correlation of synchrotron microtomograms. , 2017, Journal of biomechanics.

[21]  Gianluca Tozzi,et al.  Strain uncertainties from two digital volume correlation approaches in prophylactically augmented vertebrae: Local analysis on bone and cement-bone microstructures. , 2017, Journal of the mechanical behavior of biomedical materials.

[22]  Gianluca Tozzi,et al.  Digital volume correlation can be used to estimate local strains in natural and augmented vertebrae: An organ-level study. , 2016, Journal of biomechanics.

[23]  S Lanceros-Mendez,et al.  Differentiation of mesenchymal stem cells for cartilage tissue engineering: Individual and synergetic effects of three-dimensional environment and mechanical loading. , 2016, Acta biomaterialia.

[24]  Gianluca Tozzi,et al.  The use of digital image correlation in the biomechanical area: a review , 2016 .

[25]  Ulrich Hansen,et al.  Digital volume correlation and micro-CT: An in-vitro technique for measuring full-field interface micromotion around polyethylene implants. , 2015, Journal of biomechanics.

[26]  Gianluca Tozzi,et al.  Three-dimensional local measurements of bone strain and displacement: comparison of three digital volume correlation approaches. , 2015, Journal of biomechanical engineering.

[27]  M Viceconti,et al.  About the inevitable compromise between spatial resolution and accuracy of strain measurement for bone tissue: a 3D zero-strain study. , 2014, Journal of biomechanics.

[28]  Egon Perilli,et al.  Application of the digital volume correlation technique for the measurement of displacement and strain fields in bone: a literature review. , 2014, Journal of biomechanics.

[29]  Fabrice Pierron,et al.  Elastic stiffness characterization using three-dimensional full-field deformation obtained with optical coherence tomography and digital volume correlation , 2013, Journal of biomedical optics.

[30]  F. Hild,et al.  Computation of full-field displacements in a scaffold implant using digital volume correlation and finite element analysis. , 2013, Medical engineering & physics.

[31]  Laurent Milot,et al.  Inter- and intra-operator reliability and repeatability of shear wave elastography in the liver: a study in healthy volunteers. , 2013, Ultrasound in medicine & biology.

[32]  François Hild,et al.  3D Digital Volume Correlation of Synchrotron Radiation Laminography Images of Ductile Crack Initiation: An Initial Feasibility Study , 2013 .

[33]  Johannes E. Schindelin,et al.  Fiji: an open-source platform for biological-image analysis , 2012, Nature Methods.

[34]  Stéphane Roux,et al.  Voxel-Scale Digital Volume Correlation , 2011 .

[35]  Stéphane Roux,et al.  3D analysis from micro-MRI during in situ compression on cancellous bone. , 2009, Journal of biomechanics.

[36]  S. Roux,et al.  Three dimensional image correlation from X-Ray computed tomography of solid foam , 2007, 0712.2642.

[37]  Josep A Planell,et al.  Simulation of tissue differentiation in a scaffold as a function of porosity, Young's modulus and dissolution rate: application of mechanobiological models in tissue engineering. , 2007, Biomaterials.

[38]  G. Ravichandran,et al.  Three-dimensional Full-field Measurements of Large Deformations in Soft Materials Using Confocal Microscopy and Digital Volume Correlation , 2007 .

[39]  Peter Behrens,et al.  Matrix-associated autologous chondrocyte transplantation/implantation (MACT/MACI)--5-year follow-up. , 2006, The Knee.

[40]  S. S. Stevens,et al.  Mechanobiology in the development, maintenance, and degeneration of articular cartilage. , 2000, Journal of rehabilitation research and development.

[41]  B. Bay,et al.  Digital volume correlation: Three-dimensional strain mapping using X-ray tomography , 1999 .

[42]  Bruce M. Novak,et al.  Hybrid nanocomposite materials―between inorganic glasses and organic polymers , 1993 .

[43]  I. Jandejsek,et al.  Precise strain measurement in complex materials using Digital Volumetric Correlation and time lapse micro-CT data , 2011 .

[44]  E. Morgan,et al.  Accuracy and precision of digital volume correlation in quantifying displacements and strains in trabecular bone. , 2007, Journal of biomechanics.

[45]  Dominique Jeulin,et al.  Mesure tridimensionnelle de champs cinématiques par imagerie volumique pour l'analyse des matériaux et des structures , 2004 .