Measuring Gait Using a Ground Laser Range Sensor

This paper describes a measurement system designed to register the displacement of the legs using a two-dimensional laser range sensor with a scanning plane parallel to the ground and extract gait parameters. In the proposed methodology, the position of the legs is estimated by fitting two circles with the laser points that define their contour and the gait parameters are extracted applying a step-line model to the estimated displacement of the legs to reduce uncertainty in the determination of the stand and swing phase of the gait. Results obtained in a range up to 8 m shows that the systematic error in the location of one static leg is lower than 10 mm with and standard deviation lower than 8 mm; this deviation increases to 11 mm in the case of a moving leg. The proposed measurement system has been applied to estimate the gait parameters of six volunteers in a preliminary walking experiment.

[1]  M. Morris Movement disorders in people with Parkinson disease: a model for physical therapy. , 2000, Physical therapy.

[2]  Hans-Jürgen Warnecke,et al.  Least-squares orthogonal distances fitting of circle, sphere, ellipse, hyperbola, and parabola , 2001, Pattern Recognit..

[3]  Reynaldo Martorell,et al.  Body Size, Adaptation and Function , 1989 .

[4]  Jeffrey M. Hausdorff,et al.  Gait variability and fall risk in community-living older adults: a 1-year prospective study. , 2001, Archives of physical medicine and rehabilitation.

[5]  Jerome L. Martin Function of the Human Body 4th ed , 1974 .

[6]  J. Little,et al.  Recognizing People by Their Gait: The Shape of Motion , 1998 .

[7]  G. Gate,et al.  Using targets appearance to improve pedestrian classification with a laser scanner , 2008, 2008 IEEE Intelligent Vehicles Symposium.

[8]  Christoph Mertz,et al.  Pedestrian Detection and Tracking Using Three-dimensional LADAR Data , 2010, Int. J. Robotics Res..

[9]  J. Cutting,et al.  Recognizing friends by their walk: Gait perception without familiarity cues , 1977 .

[10]  G. Kwakkel,et al.  Effects of external rhythmical cueing on gait in patients with Parkinson's disease: a systematic review , 2005, Clinical rehabilitation.

[11]  J B King,et al.  Gait Analysis. An Introduction , 1992 .

[12]  Gang Qian,et al.  People Identification Using Gait Via Floor Pressure Sensing and Analysis , 2008, EuroSSC.

[13]  Alexandre Escolà,et al.  Real-Time Tree-Foliage Surface Estimation Using a Ground Laser Scanner , 2007, IEEE Transactions on Instrumentation and Measurement.

[14]  H. S. Wolff,et al.  iRun: Horizontal and Vertical Shape of a Region-Based Graph Compression , 2022, Sensors.

[15]  Thierry Chateau,et al.  A method based on multilayer laserscanner to detect and track pedestrians in urban environment , 2009, 2009 IEEE Intelligent Vehicles Symposium.

[16]  Joseph A. Paradiso,et al.  Gait Analysis Using a Shoe-Integrated Wireless Sensor System , 2008, IEEE Transactions on Information Technology in Biomedicine.

[17]  J. Cutting,et al.  Recognizing the sex of a walker from a dynamic point-light display , 1977 .

[18]  Carmen Peota,et al.  Body work. , 2007, Minnesota medicine.

[19]  Takashi Tsubouchi,et al.  1Km autonomous robot navigation on outdoor pedestrian paths “running the Tsukuba challenge 2007” , 2008, 2008 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[20]  Antonio Bandera,et al.  Curvature-Based Environment Description for Robot Navigation Using Laser Range Sensors , 2009, Sensors.

[21]  Ramanathan Sugumaran,et al.  Seasonal Effect on Tree Species Classification in an Urban Environment Using Hyperspectral Data, LiDAR, and an Object-Oriented Approach , 2008, Sensors.

[22]  Alan Swanson,et al.  Using a LIDAR Vegetation Model to Predict UHF SAR Attenuation in Coniferous Forests , 2009, Sensors.

[23]  M. Farjas Abadia,et al.  Applying Topographic Techniques to Modelling the Human Shape in Motion , 2007, Second Workshop on Digital Media and its Application in Museum & Heritages (DMAMH 2007).

[24]  Peter H Veltink,et al.  Accelerometer and rate gyroscope measurement of kinematics: an inexpensive alternative to optical motion analysis systems. , 2002, Journal of biomechanics.

[25]  Liang Wang,et al.  Abnormal Walking Gait Analysis Using Silhouette-Masked Flow Histograms , 2006, 18th International Conference on Pattern Recognition (ICPR'06).