Maximum-likelihood dual-energy tomographic image reconstruction

Dual-energy (DE) X-ray computed tomography (CT) has shown promise for material characterization and for providing quantitatively accurate CT values in a variety of applications. However, DE-CT has not been used routinely in medicine to date, primarily due to dose considerations. Most methods for DE-CT have used the filtered backprojection method for image reconstruction, leading to suboptimal noise/dose properties. This paper describes a statistical (maximum-likelihood) method for dual-energy X-ray CT that accommodates a wide variety of potential system configurations and measurement noise models. Regularized methods (such as penalized-likelihood or Bayesian estimation) are straightforward extensions. One version of the algorithm monotonically decreases the negative log-likelihood cost function each iteration. An ordered-subsets variation of the algorithm provides a fast and practical version.

[1]  C van Kuijk,et al.  Selection of fat-equivalent materials in postprocessing dual-energy quantitative CT. , 1992, Medical physics.

[2]  Fredrick L. Roder,et al.  Explosives Detection By Dual-Energy Computed Tomography (CT) , 1979, Other Conferences.

[3]  Sephton Rg,et al.  The potential accuracy of dual-energy computed tomography for the determination of hepatic iron. , 1986 .

[4]  A. Macovski,et al.  Initial results with prereconstruction dual-energy computed tomography (PREDECT). , 1981, Radiology.

[5]  J E Holden,et al.  Correction for scattered radiation and other background signals in dual-energy computed tomography material thickness measurements. , 1988, Medical physics.

[6]  B. Hasegawa,et al.  Systematic bias in basis material decomposition applied to quantitative dual-energy x-ray imaging. , 1992, Medical physics.

[7]  Soung Chang Liew,et al.  Correction of energy-dependent systematic errors in dual-energy X-ray CT using a basis material coefficients transformation method , 1996 .

[8]  P. Suetens,et al.  Metal streak artifacts in X-ray computed tomography: a simulation study , 1998, 1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255).

[9]  D. Mariano-Goulart,et al.  Prototype of dual energy x-ray tomodensimeter for lumbar spine bone mineral density measurement: choice of the reconstruction algorithm and first experimental results. , 1992, Physics in medicine and biology.

[10]  A. Macovski,et al.  Energy-selective reconstructions in X-ray computerised tomography , 1976, Physics in medicine and biology.

[11]  Hakan Erdogan,et al.  Ordered subsets algorithms for transmission tomography. , 1999, Physics in medicine and biology.

[12]  P M Joseph,et al.  A method for simultaneous correction of spectrum hardening artifacts in CT images containing both bone and iodine. , 1997, Medical physics.

[13]  J F Sutcliffe,et al.  A review of in vivo experimental methods to determine the composition of the human body. , 1996, Physics in medicine and biology.

[14]  Yoram Bresler,et al.  Optimal scan for time-varying tomography. I. Theoretical analysis and fundamental limitations , 1995, IEEE Trans. Image Process..

[15]  W. Kalender,et al.  An algorithm for noise suppression in dual energy CT material density images. , 1988, IEEE transactions on medical imaging.

[16]  W. Graeff,et al.  In situ measurement of iron overload in liver tissue by dual-energy methods. , 1996, Physics in medicine and biology.

[17]  P. Rizo,et al.  ESTIMATION OF THE MATRIX ATTENUATION IN HETEROGENEOUS RADIOACTIVE WASTE DRUMS USING DUAL-ENERGY COMPUTED TOMOGRAPHY , 1999 .

[18]  Chye Hwang Yan,et al.  Reconstruction algorithm for polychromatic CT imaging: application to beam hardening correction , 2000, IEEE Transactions on Medical Imaging.

[19]  W. Kalender,et al.  Evaluation of a prototype dual-energy computed tomographic apparatus. II. Determination of vertebral bone mineral content. , 1986, Medical physics.

[20]  Neal H. Clinthorne,et al.  Design of an experimental system for dual energy X-ray CT , 1999, 1999 IEEE Nuclear Science Symposium. Conference Record. 1999 Nuclear Science Symposium and Medical Imaging Conference (Cat. No.99CH37019).

[21]  R. Sephton,et al.  The potential accuracy of dual-energy computed tomography for the determination of hepatic iron. , 1986, The British journal of radiology.

[22]  M M Goodsitt,et al.  The Composition of Bone Marrow for a Dual-Energy Quantitative Computed Tomography Technique: A Cadaver and Computer Simulation Study , 1994, Investigative radiology.

[23]  J. Fitzpatrick,et al.  Medical image processing and analysis , 2000 .

[24]  Jeffrey A. Fessler,et al.  Statistical image reconstruction methods for randoms-precorrected PET scans , 1998, Medical Image Anal..

[25]  R. White,et al.  Image recovery from data acquired with a charge-coupled-device camera. , 1993, Journal of the Optical Society of America. A, Optics and image science.

[26]  W D McDavid,et al.  Extraction of information from CT scans at different energies. , 1979, Medical physics.

[27]  R. P. Parker,et al.  Tissue analysis by dual-energy computed tomography. , 1986, The British journal of radiology.

[28]  A. Coleman,et al.  A beam-hardening correction using dual-energy computed tomography. , 1985, Physics in medicine and biology.

[29]  P. Sukovic,et al.  Data weighted vs. non-data weighted dual energy reconstructions for X-ray tomography , 1998, 1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255).

[30]  M. Abidi,et al.  Reconstruction of multi-energy X-ray computed tomography images of laboratory mice , 1999 .

[31]  Neal H. Clinthorne Are hydrogenated amorphous silicon arrays usable for tomographic imaging , 1993 .

[32]  H K Huang,et al.  A fast dual-energy computational method using isotransmission lines and table lookup. , 1987, Medical physics.

[33]  Patrick Dupont,et al.  An iterative maximum-likelihood polychromatic algorithm for CT , 2001, IEEE Transactions on Medical Imaging.

[34]  Soo Chin Liew,et al.  Object-specific attenuation correction of SPECT with correlated dual-energy X-ray CT , 1993, IEEE Transactions on Nuclear Science.

[35]  P. Joseph,et al.  A Method for Correcting Bone Induced Artifacts in Computed Tomography Scanners , 1978, Journal of computer assisted tomography.

[36]  O Nalcioglu,et al.  Post-reconstruction method for beam hardening in computerised tomography. , 1979, Physics in medicine and biology.

[37]  C van Kuijk,et al.  Influence of calibration materials in single- and dual-energy quantitative CT. , 1992, Radiology.

[38]  C. Helstrom,et al.  Compensation for readout noise in CCD images , 1995 .

[39]  A Macovski,et al.  Energy dependent reconstruction in X-ray computerized tomography. , 1976, Computers in biology and medicine.

[40]  J. Fessler Statistical Image Reconstruction Methods for Transmission Tomography , 2000 .

[41]  Hakan Erdogan,et al.  Monotonic algorithms for transmission tomography , 2002, 5th IEEE EMBS International Summer School on Biomedical Imaging, 2002..

[42]  R A Brooks,et al.  OPTIMUM ENERGIES FOR DUAL‐ENERGY COMPUTED TOMOGRAPHY , 1980, Physics in medicine and biology.

[43]  Jeffrey A. Fessler,et al.  Penalized-likelihood estimators and noise analysis for randoms-precorrected PET transmission scans , 1999, IEEE Transactions on Medical Imaging.

[44]  J B Weaver,et al.  Attenuation coefficients of body tissues using principal-components analysis. , 1985, Medical physics.

[45]  L. Sjöström,et al.  Adipose tissue volume determinations in women by computed tomography: technical considerations. , 1986, International journal of obesity.

[46]  C. Ruth,et al.  Estimation of a photon energy spectrum for a computed tomography scanner. , 1997, Medical physics.

[47]  Paulo Estevão Cruvinel,et al.  Minitomography scanner for agriculture based on dual-energy Compton scattering , 2000, Proceedings 13th Brazilian Symposium on Computer Graphics and Image Processing (Cat. No.PR00878).

[48]  W. Kalender,et al.  Evaluation of a prototype dual-energy computed tomographic apparatus. I. Phantom studies. , 1986, Medical physics.

[49]  Michael Gj Tissue analysis using dual energy CT. , 1992 .

[50]  P M Joseph,et al.  The exponential edge-gradient effect in x-ray computed tomography. , 1981, Physics in medicine and biology.

[51]  M Takai,et al.  Discrimination between thorotrast and iodine contrast medium by means of dual-energy CT scanning. , 1984, Physics in medicine and biology.

[52]  S Napel,et al.  Modeling of polychromatic attenuation using computed tomography reconstructed images. , 1999, Medical physics.

[53]  F. Beekma,et al.  Ordered subset reconstruction for x-ray CT. , 2001, Physics in medicine and biology.

[54]  K Aoki,et al.  A silicon diode in a thimble-type mount for measurement of diagnostic x-ray spectra. , 1990, Physics in medicine and biology.

[55]  A E Burgess,et al.  Vertebral trabecular bone: comparison of single and dual-energy CT measurements with chemical analysis. , 1987, Journal of computer assisted tomography.

[56]  N. H. Clinthorne,et al.  Basis material decomposition using triple-energy X-ray computed tomography , 1999, IMTC/99. Proceedings of the 16th IEEE Instrumentation and Measurement Technology Conference (Cat. No.99CH36309).

[57]  Jeffrey A. Fessler Penalized weighted least-squares image reconstruction for positron emission tomography , 1994, IEEE Trans. Medical Imaging.

[58]  Predrag Sukovic,et al.  Penalized weighted least-squares image reconstruction for dual energy X-ray transmission tomography , 2000, IEEE Transactions on Medical Imaging.

[59]  J. Hsieh,et al.  An iterative approach to the beam hardening correction in cone beam CT. , 2000, Medical physics.

[60]  Paul Kinahan,et al.  Attenuation correction for a combined 3D PET/CT scanner. , 1998, Medical physics.

[61]  Joseph A. O'Sullivan,et al.  Iterative deblurring for CT metal artifact reduction , 1996, IEEE Trans. Medical Imaging.

[62]  D N Slatkin,et al.  Single-and dual-energy CT with monochromatic synchrotron x-rays. , 1997, Physics in medicine and biology.

[63]  Neal H. Clinthorne A constrained dual-energy reconstruction method for material-selective transmission tomography , 1994 .

[64]  Michael S. Westmore,et al.  Effect of fat content on single- and dual-energy CT measurements of bone mineral: determination using a new system of tissue-mimicking phantom materials , 2000, Medical Imaging.

[65]  Benjamin M. W. Tsui,et al.  An investigation of dual energy transmission measurements in simultaneous transmission emission imaging , 1995 .

[66]  P. Joseph,et al.  Noise considerations in dual energy CT scanning. , 1979, Medical physics.

[67]  M M Goodsitt,et al.  Precision in quantitative CT: impact of x-ray dose and matrix size. , 1992, Medical physics.

[68]  B. Hasegawa,et al.  Energy dependent systematic errors in dual-energy X-ray CT , 1995, 1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record.

[69]  Joseph Fryar,et al.  Element specific imaging in computerised tomography using a tube source of X-rays and low energy-resolution detector system , 1993 .

[70]  D. Visvikis,et al.  DETECT-dual energy transmission estimation CT-for improved attenuation correction in SPECT and PET , 1997, 1997 IEEE Nuclear Science Symposium Conference Record.

[71]  W. D. Friedman,et al.  Review of dual-energy computed tomography techniques , 1990 .

[72]  E L Nickoloff,et al.  Bone mineral assessment: new dual-energy CT approach. , 1988, Radiology.

[73]  S. L. Wellington,et al.  X-ray computerized tomography , 1987 .

[74]  Jeffrey A. Fessler Mean and variance of implicitly defined biased estimators (such as penalized maximum likelihood): applications to tomography , 1996, IEEE Trans. Image Process..

[75]  P. Dunscombe,et al.  Some practical aspects of dual-energy CT scanning. , 1984, The British journal of radiology.

[76]  G J Michael Tissue analysis using dual energy CT. , 1992, Australasian physical & engineering sciences in medicine.

[77]  R. Alvarez,et al.  A Comparison of Noise and Dose in Conventional and Energy Selective Computed Tomography , 1979, IEEE Transactions on Nuclear Science.

[78]  L. Garnero,et al.  X-ray dual-energy calibration based on estimated spectral properties of the experimental system , 1998 .

[79]  M M Goodsitt Beam hardening errors in post-processing dual energy quantitative computed tomography. , 1995, Medical physics.

[80]  A Fenster,et al.  An accurate method for direct dual-energy calibration and decomposition. , 1990, Medical physics.