Efficient Model of the Collimator Blurring in Pinhole SPECT

We propose a new method for collimator blurring correction in pinhole SPECT, that uses the spherical symmetry of the blob basis functions. We study its performance and compare with the other correction methods, namely multi-ray methods. We also investigate some limitations of the multi-ray methods.

[1]  Michael A. King,et al.  CHAPTER 22 – Attenuation, Scatter, and Spatial Resolution Compensation in SPECT , 2004 .

[2]  Bruce H. Hasegawa,et al.  Quantitative SPECT reconstruction using multiray projection integrators , 1995, 1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record.

[3]  Ronald J. Jaszczak,et al.  Analytic determination of the pinhole collimator's point-spread function and RMS resolution with penetration , 2002, IEEE Transactions on Medical Imaging.

[4]  T. Schurrat,et al.  On the performance of two multi-pinhole SPECT systems for small animal research , 2004, IEEE Symposium Conference Record Nuclear Science 2004..

[5]  Grant T. Gullberg,et al.  Slab-by-slab blurring model for geometric point response correction and attenuation correction using iterative reconstruction algorithms , 1997, 1997 IEEE Nuclear Science Symposium Conference Record.

[6]  F. Beekman,et al.  Design and simulation of a high-resolution stationary SPECT system for small animals. , 2004, Physics in medicine and biology.

[7]  L.M. Popescu,et al.  Ray tracing through a grid of blobs , 2004, IEEE Symposium Conference Record Nuclear Science 2004..

[8]  Samuel Matej,et al.  Efficient 3D grids for image reconstruction using spherically-symmetric volume elements , 1995 .

[9]  Ronald J. Jaszczak,et al.  Analytic determination of pinhole collimator sensitivity with penetration , 2001, IEEE Transactions on Medical Imaging.

[10]  David S. Lalush,et al.  Convergence and resolution recovery of block-iterative EM algorithms modeling 3D detector response in SPECT , 1996, 1996 IEEE Nuclear Science Symposium. Conference Record.

[11]  G. Gullberg,et al.  A rotating and warping projector/backprojector for fan-beam and cone-beam iterative algorithm , 1994 .

[12]  Robert M. Lewitt,et al.  Practical considerations for 3-D image reconstruction using spherically symmetric volume elements , 1996, IEEE Trans. Medical Imaging.

[13]  M. Defrise,et al.  Correction for imperfect camera motion and resolution recovery in pinhole SPECT , 2004, IEEE Symposium Conference Record Nuclear Science 2004..

[14]  R J Jaszczak,et al.  An analytic model of pinhole aperture penetration for 3D pinhole SPECT image reconstruction. , 1998, Physics in medicine and biology.

[15]  B.M.W. Tsui,et al.  Attenuation and detector response compensations used with Gibbs prior distributions for maximum a posteriori SPECT reconstruction , 1991, Conference Record of the 1991 IEEE Nuclear Science Symposium and Medical Imaging Conference.

[16]  Freek J Beekman,et al.  Monte Carlo simulations of pinhole imaging accelerated by kernel-based forced detection. , 2002, Physics in medicine and biology.

[17]  J A Fessler,et al.  A comparison of rotation- and blob-based system models for 3D SPECT with depth-dependent detector response. , 2004, Physics in medicine and biology.

[18]  Donald W. Wilson,et al.  FastSPECT II: a second-generation high-resolution dynamic SPECT imager , 2002, IEEE Transactions on Nuclear Science.

[19]  S. Meikle,et al.  Small animal SPECT and its place in the matrix of molecular imaging technologies , 2005, Physics in medicine and biology.

[20]  R. Lewitt Alternatives to voxels for image representation in iterative reconstruction algorithms , 1992, Physics in medicine and biology.