Individual variability analysis of fluorescence parameters measured in skin with different levels of nutritive blood flow.

Fluorescence spectroscopy has recently become more common in clinical medicine. However, there are still many unresolved issues related to the methodology and implementation of instruments with this technology. In this study, we aimed to assess individual variability of fluorescence parameters of endogenous markers (NADH, FAD, etc.) measured by fluorescent spectroscopy (FS) in situ and to analyse the factors that lead to a significant scatter of results. Most studied fluorophores have an acceptable scatter of values (mostly up to 30%) for diagnostic purposes. Here we provide evidence that the level of blood volume in tissue impacts FS data with a significant inverse correlation. The distribution function of the fluorescence intensity and the fluorescent contrast coefficient values are a function of the normal distribution for most of the studied fluorophores and the redox ratio. The effects of various physiological (different content of skin melanin) and technical (characteristics of optical filters) factors on the measurement results were additionally studied. The data on the variability of the measurement results in FS should be considered when interpreting the diagnostic parameters, as well as when developing new algorithms for data processing and FS devices.

[1]  P A Oberg,et al.  Rhythmical variations in human skin blood flow. , 1983, International journal of microcirculation, clinical and experimental.

[2]  Tuan Vo-Dinh,et al.  Compact point-detection fluorescence spectroscopy system for quantifying intrinsic fluorescence redox ratio in brain cancer diagnostics. , 2011, Journal of biomedical optics.

[3]  J. Mandel,et al.  The Statistical Analysis of Experimental Data. , 1965 .

[4]  V. Bagnato,et al.  Autofluorescence spectroscopy in liver transplantation: preliminary results from a pilot clinical study. , 2008, Transplantation proceedings.

[5]  Victor B. Loschenov,et al.  Photodynamic Therapy and Fluorescence Diagnostics , 2000 .

[6]  Shigeyuki Ochi,et al.  Charge-Coupled Device Technology , 1997 .

[7]  Steven L. Jacques,et al.  Internal absorption coefficient and threshold for pulsed laser disruption of melanosomes isolated from retinal pigment epithelium , 1996, Photonics West.

[8]  Stefan Andersson-Engels,et al.  Fluorescence spectra provide information on the depth of fluorescent lesions in tissue. , 2005, Applied optics.

[9]  D. Y. Churmakov,et al.  Analysis of skin tissues spatial fluorescence distribution by the Monte Carlo simulation , 2003 .

[10]  V. Seewaldt,et al.  Tumor and Stem Cell Biology Cancer Research Optical Redox Ratio Differentiates Breast Cancer Cell Lines Based on Estrogen Receptor Status , 2010 .

[11]  J. Lakowicz Principles of fluorescence spectroscopy , 1983 .

[12]  D. Fielding,et al.  Autofluorescence improves pretreatment mucosal assessment in head and neck cancer patients , 2010, Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery.

[13]  I. Meglinski,et al.  Amending of fluorescence sensor signal localization in human skin by matching of the refractive index. , 2004, Journal of biomedical optics.

[14]  D. A. Rogatkin,et al.  Analysis of the accuracy of clinical laser fluorescence diagnosis , 1998 .

[15]  Andrey V. Dunaev,et al.  Laser reflectance oximetry and Doppler flowmetry in assessment of complex physiological parameters of cutaneous blood microcirculation , 2013, Photonics West - Biomedical Optics.

[16]  R. Marchesini,et al.  Natural fluorescence of normal and neoplastic human colon: A comprehensive “ex vivo” study , 1995, Lasers in surgery and medicine.

[17]  Valery V. Tuchin,et al.  Physical modeling of tissue fluorescence: phantom development , 1999, European Conference on Biomedical Optics.

[18]  Renato Amaro Zângaro,et al.  Discriminating model for diagnosis of basal cell carcinoma and melanoma in vitro based on the Raman spectra of selected biochemicals , 2012, Journal of biomedical optics.

[19]  Haishan Zeng,et al.  Cutaneous melanin exhibiting fluorescence emission under near-infrared light excitation. , 2006, Journal of biomedical optics.

[20]  N. Ramanujam,et al.  In vivo multiphoton microscopy of NADH and FAD redox states, fluorescence lifetimes, and cellular morphology in precancerous epithelia , 2007, Proceedings of the National Academy of Sciences.

[21]  D. A. Rogatkin,et al.  Metrological Support of Methods and Devices for Noninvasive Medical Spectrophotometry , 2010, BioMed 2010.

[22]  N. A. Stewart,et al.  Substantiation of medical and technical requirements for noninvasive spectrophotometric diagnostic devices , 2013, Journal of biomedical optics.

[23]  H.J.C.M. Sterenborg,et al.  Skin optics , 1989, IEEE Transactions on Biomedical Engineering.

[24]  D. A. Rogatkin,et al.  Basic principles of design and functioning of multifunctional laser diagnostic system for non-invasive medical spectrophotometry , 2011, BiOS.

[25]  M. Mycek,et al.  Handbook of Biomedical Fluorescence , 2003 .

[26]  Anastasia V. Ryabova,et al.  Application of backward diffuse reflection spectroscopy for monitoring the state of tissues in photodynamic therapy , 2006 .

[27]  Dinh Tuan Vo Biomedical photonics handbook , 2003 .

[28]  D. A. Rogatkin,et al.  Principal Sources of Errors in Noninvasive Medical Spectrophotometry. Part 2. Medicobiological Factors of Errors , 2013 .

[29]  V. Tuchin Handbook of Optical Biomedical Diagnostics , 2002 .

[30]  Urs Utzinger,et al.  Endogenous Fluorescence Spectroscopy of Cell Suspensions for Chemopreventive Drug Monitoring¶ , 2005, Photochemistry and photobiology.

[31]  Vladimir Efimovich Gmurman,et al.  Fundamentals of probability theory and mathematical statistics , 1968 .

[32]  Lihong V. Wang,et al.  Monte Carlo Modeling of Light Transport in Tissues , 1995 .

[33]  E. Rafailov,et al.  In vivo noninvasive measurement of skin autofluorescence biomarkers relate to cardiovascular disease in mice , 2014, Journal of microscopy.

[34]  Yan A. Su,et al.  Two types of human malignant melanoma cell lines revealed by expression patterns of mitochondrial and survival-apoptosis genes: implications for malignant melanoma therapy , 2009, Molecular Cancer Therapeutics.

[35]  K. Litvinova,et al.  COLLAGEN AS IN VIVO QUANTITATIVE FLUORESCENT BIOMARKERS OF ABNORMAL TISSUE CHANGES , 2012 .

[36]  Victor B. Loschenov,et al.  Photodynamic therapy of acne vulgaris. , 2003, SPIE BiOS.

[37]  B. Wilson,et al.  A Monte Carlo model for the absorption and flux distributions of light in tissue. , 1983, Medical physics.

[38]  I. Meglinski,et al.  Quantitative assessment of skin layers absorption and skin reflectance spectra simulation in the visible and near-infrared spectral regions. , 2002, Physiological measurement.

[39]  Yuting Lin,et al.  Fluorescence diffuse optical tomography with functional and anatomical a priori information: feasibility study , 2007, Physics in medicine and biology.

[40]  V. V. Tchernyi,et al.  Some results of multiwave in situ autofluorescence diagnostics , 2005, SPIE BiOS.

[41]  D. A. Rogatkin,et al.  Principal Sources of Errors in Noninvasive Medical Spectrophotometry. Part 1. Physicotechnical Sources and Factors of Errors , 2013 .