Sensitivity of Compressed Spectral Arrays for Detecting Seizures in Acutely Ill Adults

BackgroundContinuous EEG recordings (cEEGs) are increasingly used in evaluation of acutely ill adults. Pre-screening using compressed data formats, such as compressed spectral array (CSA), may accelerate EEG review. We tested whether screening with CSA can enable detection of seizures and other relevant patterns.MethodsTwo individuals reviewed the CSA displays of 113 cEEGs. While blinded to the raw EEG data, they marked each visually homogeneous CSA segment. An independent experienced electroencephalographer reviewed the raw EEG within 60 s on either side of each mark and recorded any seizures (and isolated epileptiform discharges, periodic epileptiform discharges (PEDs), rhythmic delta activity (RDA), and focal or generalized slowing). Seizures were considered to have been detected if the CSA mark was within 60 s of the seizure. The electroencephalographer then determined the total number of seizures (and other critical findings) for each record by exhaustive, page-by-page review of the entire raw EEG.ResultsWithin each of the 39 cEEG recordings containing seizures, one CSA reviewer identified at least one seizure, while the second CSA reviewer identified 38/39 patients with seizures. The overall detection rate was 89.0 % of 1,190 total seizures. When present, an average of 87.9 % of seizures were detected per individual patient. Detection rates for other critical findings were as follows: epileptiform discharges, 94.0 %; PEDs, 100 %; RDA, 97.9 %; focal slowing, 100 %; and generalized slowing, 100 %.ConclusionsCSA-guided review can support sensitive screening of critical pathological information in cEEG recordings. However, some patients with seizures may not be identified.

[1]  Jan Claassen,et al.  Frequency and predictors of nonconvulsive seizures during continuous electroencephalographic monitoring in critically ill children. , 2006, Archives of neurology.

[2]  S. Mayer,et al.  Continuous electroencephalography in the medical intensive care unit* , 2009, Critical care medicine.

[3]  A. Bricolo,et al.  Clinical application of compressed spectral array in long-term EEG monitoring of comatose patients. , 1978, Electroencephalography and clinical neurophysiology.

[4]  Robert R. Clancy,et al.  Sensitivity of Amplitude-Integrated Electroencephalography for Neonatal Seizure Detection , 2007, Pediatrics.

[5]  Terrie E. Inder,et al.  Accuracy of Bedside Electroencephalographic Monitoring in Comparison With Simultaneous Continuous Conventional Electroencephalography for Seizure Detection in Term Infants , 2008, Pediatrics.

[6]  Joshua R. Smith,et al.  Prevalence of nonconvulsive status epilepticus in comatose patients , 2000, Neurology.

[7]  M. Nuwer,et al.  Increased incidence and impact of nonconvulsive and convulsive seizures after traumatic brain injury as detected by continuous electroencephalographic monitoring. , 1999, Journal of neurosurgery.

[8]  F. Torres,et al.  Continuous electrophysiologic monitoring of cerebral function in the pediatric intensive care unit. , 1988, Pediatric neurology.

[9]  E. Kobylarz,et al.  Electroencephalographic patterns in unresponsive pediatric patients. , 2005, Pediatric neurology.

[10]  G. B. Young,et al.  Prognostic Determination in Anoxic-Ischemic and Traumatic Encephalopathies , 2004, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[11]  Linda S de Vries,et al.  Comparison between simultaneously recorded amplitude integrated electroencephalogram (cerebral function monitor) and standard electroencephalogram in neonates. , 2002, Pediatrics.

[12]  G B Boylan,et al.  Non-expert use of the cerebral function monitor for neonatal seizure detection , 2004, Archives of disease in childhood. Fetal and neonatal edition.

[13]  G. B. Young,et al.  Continuous EEG monitoring in comatose intensive care patients , 2005, Neurocritical care.

[14]  H. Otsubo,et al.  Seizure identification in the ICU using quantitative EEG displays , 2010, Neurology.

[15]  Dennis Dlugos,et al.  Neonatal seizure detection using multichannel display of envelope trend , 2008, Epilepsia.

[16]  G. Cascino,et al.  Digital video-electroencephalographic monitoring in the neurological-neurosurgical intensive care unit: clinical features and outcome. , 2004, Archives of neurology.

[17]  M. Nuwer Quantitative EEG analysis in clinical settings , 1996, Brain topography.

[18]  Scott B. Wilson,et al.  Data Analysis for Continuous EEG Monitoring in the ICU: Seeing the Forest and the Trees , 2004, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[19]  L. Hirsch,et al.  Which EEG Patterns Warrant Treatment in the Critically Ill? Reviewing the Evidence for Treatment of Periodic Epileptiform Discharges and Related Patterns , 2005, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[20]  S. Mayer,et al.  Detection of electrographic seizures with continuous EEG monitoring in critically ill patients , 2004, Neurology.

[21]  K. Jordan Nonconvulsive status epilepticus in acute brain injury. , 1999, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[22]  K. Jordan Continuous EEG and Evoked Potential Monitoring in the Neuroscience Intensive Care Unit , 1993, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[23]  Tammy N Tsuchida,et al.  Amplitude-integrated electroencephalography in neonates. , 2009, Pediatric neurology.

[24]  A. Liu,et al.  Detection of neonatal seizures through computerized EEG analysis. , 1992, Electroencephalography and clinical neurophysiology.

[25]  L. Hirsch,et al.  Continuous electroencephalogram monitoring in the critically III , 2005, Neurocritical care.

[26]  Cristiano Rizzo,et al.  Detection of subclinical electroencephalographic seizure patterns with multichannel amplitude-integrated EEG in full-term neonates , 2009, Clinical Neurophysiology.

[27]  M. N. Nuwer,et al.  Assessment of digital EEG, quantitative EEG, and EEG brain mapping: Report of the American Academy of Neurology and the American Clinical Neurophysiology Society* , 1997, Neurology.

[28]  T. Bleck,et al.  Status Epilepticus and the Use of Continuous EEG Monitoring in the Intensive Care Unit , 2012, Continuum.