Particle characterisation and cytokine expression in failed small-diameter metal-on-metal total hip arthroplasties.

The peri-prosthetic tissue response to wear debris is complex and influenced by various factors including the size, area and number of particles. We hypothesised that the 'biologically active area' of all metal wear particles may predict the type of peri-prosthetic tissue response. Peri-prosthetic tissue was sampled from 21 patients undergoing revision of a small diameter metal-on-metal (MoM) total hip arthroplasty (THA) for aseptic loosening. An enzymatic protocol was used for tissue digestion and scanning electron microscope was used to characterise particles. Equivalent circle diameters and particle areas were calculated. Histomorphometric analyses were performed on all tissue specimens. Aspirates of synovial fluid were collected for analysis of the cytokine profile analysis, and compared with a control group of patients undergoing primary THA (n = 11) and revision of a failed ceramic-on-polyethylene arthroplasty (n = 6). The overall distribution of the size and area of the particles in both lymphocyte and non-lymphocyte-dominated responses were similar; however, the subgroup with lymphocyte-dominated peri-prosthetic tissue responses had a significantly larger total number of particles. 14 cytokines (interleukin (IL)-1ß, IL-2, IL-4, IL-5, IL-6, IL-10, IL-13, IL-17, interferon (IFN)-γ, and IFN-gamma-inducible protein 10), chemokines (macrophage inflammatory protein (MIP)-1α and MIP-1ß), and growth factors (granulocyte macrophage colony stimulating factor (GM-CSF) and platelet derived growth factor) were detected at significantly higher levels in patients with metal wear debris compared with the control group. Significantly higher levels for IL-1ß, IL-5, IL-10 and GM-CSF were found in the subgroup of tissues from failed MoM THAs with a lymphocyte-dominated peri-prosthetic response compared with those without this response. These results suggest that the 'biologically active area' predicts the type of peri-prosthetic tissue response. The cytokines IL-1ß, IL-5, IL-10, and GM-CSF are associated with lymphocyte-dominated tissue responses from failed small-diameter MoM THA.

[1]  P. Campbell,et al.  Can Wear Explain the Histological Variation Around Metal-on-metal Total Hips? , 2015, Clinical orthopaedics and related research.

[2]  Y. H. Kim,et al.  Prevalence of a soft-tissue lesion after small head metal-on-metal total hip replacement: 13- to 19-year follow-up study. , 2014, The bone & joint journal.

[3]  A. Eskelinen,et al.  Adverse reaction to metal debris is more common in patients following MoM total hip replacement with a 36 mm femoral head than previously thought: results from a modern MoM follow-up programme. , 2014, The bone & joint journal.

[4]  M. Dunbar,et al.  Metal-on-metal hip surface replacement: the routine use is not justified. , 2014, The bone & joint journal.

[5]  J. Thyssen,et al.  Contributions of human tissue analysis to understanding the mechanisms of loosening and osteolysis in total hip replacement. , 2014, Acta biomaterialia.

[6]  M. Morlock,et al.  Periprosthetic tissue metal content but not serum metal content predicts the type of tissue response in failed small-diameter metal-on-metal total hip arthroplasties. , 2013, The Journal of bone and joint surgery. American volume.

[7]  G. Klein,et al.  Metal-on-metal total hip arthroplasty: causes and high incidence of early failure. , 2012, Orthopedics.

[8]  K. An,et al.  Joint Replacement Arthroplasty: Basic Science, Hip, Knee, and Ankle , 2012 .

[9]  W. P. Barrett,et al.  Large-diameter modular metal-on-metal total hip arthroplasty: incidence of revision for adverse reaction to metallic debris. , 2012, The Journal of arthroplasty.

[10]  A. Sudo,et al.  Cobalt and chromium ion release after large-diameter metal-on-metal total hip arthroplasty. , 2012, The Journal of arthroplasty.

[11]  K. Weber,et al.  Modern metal-on-metal hip implants. , 2012, The Journal of the American Academy of Orthopaedic Surgeons.

[12]  A. Hart,et al.  Metal-On-Metal Bearings, Inflammatory Pseudotumours and Their Neurological Manifestations , 2012, Hip international : the journal of clinical and experimental research on hip pathology and therapy.

[13]  F. Haddad,et al.  Metal-on-metal bearings: the evidence so far. , 2011, The Journal of bone and joint surgery. British volume.

[14]  N. Arden,et al.  High failure rates with a large-diameter hybrid metal-on-metal total hip replacement: clinical, radiological and retrieval analysis. , 2011, The Journal of bone and joint surgery. British volume.

[15]  W. Mihalko,et al.  The evolution and modern use of metal-on-metal bearings in total hip arthroplasty. , 2011, Instructional course lectures.

[16]  I. Learmonth,et al.  Metal-on-metal bearings total hip arthroplasty: the cobalt and chromium ions release concern. , 2010, Orthopaedics & traumatology, surgery & research : OTSR.

[17]  Y. Iwakura,et al.  Periprosthetic osteolysis: Characterizing the innate immune response to titanium wear‐particles , 2010, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[18]  P. Korovessis,et al.  Immunologic Adverse Reaction Associated with Low-carbide Metal-on-metal Bearings in Total Hip Arthroplasty , 2010, Clinical orthopaedics and related research.

[19]  D. Berry,et al.  Failed Metal-on-Metal Hip Arthroplasties: A Spectrum of Clinical Presentations and Operative Findings , 2010, Clinical orthopaedics and related research.

[20]  T J Joyce,et al.  Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement: A consequence of excess wear. , 2010, The Journal of bone and joint surgery. British volume.

[21]  S. Stea,et al.  Assessment of five interleukins in human synovial fluid as possible markers for aseptic loosening of hip arthroplasty. , 2009, Artificial organs.

[22]  O. Reikerås,et al.  Systemic and Local Cytokine Kinetics after Total Hip Replacement Surgery , 2008, European Surgical Research.

[23]  P. E. Purdue Alternative macrophage activation in periprosthetic osteolysis , 2008, Autoimmunity.

[24]  S. Goodman Wear particles, periprosthetic osteolysis and the immune system. , 2007, Biomaterials.

[25]  C. Lohmann,et al.  Hypersensitivity reactions in total hip arthroplasty. , 2007, Orthopedics.

[26]  D. Hungerford,et al.  Extraction and characterization of metallic wear debris from total joint arthroplasty. , 2007, Biomedical sciences instrumentation.

[27]  S. Fox,et al.  RANKL-dependent and RANKL-independent mechanisms of macrophage-osteoclast differentiation in breast cancer , 2007, Breast Cancer Research and Treatment.

[28]  Thomas P. Sculco,et al.  The Central Role of Wear Debris in Periprosthetic Osteolysis , 2006, HSS Journal.

[29]  B. Bierbaum,et al.  The role played by cell-substrate interactions in the pathogenesis of osteoclast-mediated peri-implant osteolysis , 2006, Arthritis Research & Therapy.

[30]  A. Cobb,et al.  The clinical significance of metal ion release from cobalt-chromium metal-on-metal hip joint arthroplasty , 2006, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[31]  O. Reikerås,et al.  Systemic and local cytokine patterns during total hip surgery , 2006, Scandinavian journal of clinical and laboratory investigation.

[32]  M. Bauer,et al.  Transcriptomic and Proteomic Patterns of Systemic Inflammation in On-Pump and Off-Pump Coronary Artery Bypass Grafting , 2005, Circulation.

[33]  T. Glant,et al.  Lymphocyte responses in patients with total hip arthroplasty , 2005, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[34]  C. Lohmann,et al.  Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study. , 2005, The Journal of bone and joint surgery. American volume.

[35]  John Fisher,et al.  Metal-on-metal bearing wear with different swing phase loads. , 2004, Journal of biomedical materials research. Part B, Applied biomaterials.

[36]  John B Medley,et al.  Comparison of in vitro with in vivo characteristics of wear particles from metal-metal hip implants. , 2004, Journal of biomedical materials research. Part B, Applied biomaterials.

[37]  D. Zukor,et al.  Size, shape, and composition of wear particles from metal-metal hip simulator testing: effects of alloy and number of loading cycles. , 2003, Journal of biomedical materials research. Part A.

[38]  N. Athanasou,et al.  The effect of particle size and electrical charge on macrophage-osteoclast differentiation and bone resorption , 2003, Journal of materials science. Materials in medicine.

[39]  T. Bauer Particles and periimplant bone resorption. , 2002, Clinical orthopaedics and related research.

[40]  C. Nelson,et al.  Tumour necrosis factor superfamily cytokines and the pathogenesis of inflammatory osteolysis , 2002, Annals of the rheumatic diseases.

[41]  E. Schwarz,et al.  Viral interleukin-10 gene inhibition of inflammation, osteoclastogenesis, and bone resorption in response to titanium particles. , 2002, Arthritis and rheumatism.

[42]  P. Revell,et al.  Phenotypic characteristics of T lymphocytes in the interfacial tissue of aseptically loosened prosthetic joints , 2001, Journal of materials science. Materials in medicine.

[43]  J Fisher,et al.  Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested in a physiological hip joint simulator. , 2001, Bio-medical materials and engineering.

[44]  B. Wroblewski,et al.  Evaluation of the response of primary human peripheral blood mononuclear phagocytes to challenge with in vitro generated clinically relevant UHMWPE particles of known size and dose. , 2000, Journal of biomedical materials research.

[45]  J. Fisher,et al.  Quantitative analysis of the wear and wear debris from low and high carbon content cobalt chrome alloys used in metal on metal total hip replacements , 1999, Journal of materials science. Materials in medicine.

[46]  C. Rieker,et al.  Analysis of 118 second-generation metal-on-metal retrieved hip implants , 1999 .

[47]  Jack R. Worrall,et al.  Metal wear particle characterization from metal on metal total hip replacements: transmission electron microscopy study of periprosthetic tissues and isolated particles. , 1998, Journal of biomedical materials research.

[48]  S. Goodman,et al.  Effect of size, concentration, surface area, and volume of polymethylmethacrylate particles on human macrophages in vitro. , 1996, Journal of biomedical materials research.

[49]  J. Galante,et al.  Human monocyte response to particulate biomaterials generated in vivo and in vitro , 1995, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[50]  W. Maloney,et al.  Isolation and characterization of wear particles generated in patients who have had failure of a hip arthroplasty without cement. , 1995, The Journal of bone and joint surgery. American volume.

[51]  W H Harris,et al.  Production of cytokines around loosened cemented acetabular components. Analysis with immunohistochemical techniques and in situ hybridization. , 1993, The Journal of bone and joint surgery. American volume.

[52]  J. Hock,et al.  Colony-stimulating factors regulate the development of multinucleated osteoclasts from recently replicated cells in vitro. , 1987, The Journal of clinical investigation.

[53]  G. Mundy,et al.  Effects of human recombinant CSF‐GM and highly purified CSF‐1 on the formation of multinucleated cells with osteoclast characteristics in long‐term bone marrow cultures , 1986, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[54]  M. Semlitsch,et al.  Reactions of the articular capsule to wear products of artificial joint prostheses. , 1977, Journal of biomedical materials research.