Radiation-induced skin injury after complex endovascular procedures.

BACKGROUND Radiation-induced skin injury is a serious potential complication of fluoroscopically guided interventions. Transient erythema occurs at doses of 2 to 5 Gy, whereas permanent epilation, ulceration, and desquamation are expected at doses above this level. Complex endovascular procedures (CEPs), such as fenestrated endovascular aortic aneurysm repair (FEVAR), are associated with high radiation doses, yet the prevalence of radiation-induced skin injury is unknown. We hypothesized that skin injury after these exposures is likely to be underrecognized and underreported. This study examined the frequency and severity of deterministic effects and evaluated patient characteristics that might predispose to radiation injury in CEP. METHODS CEP was defined as a procedure with a radiation dose ≥5 Gy (National Council on Radiation Protection and Measurements threshold for substantial radiation dose level [SRDL]). Radiation dose and operating factors were recorded for all CEPs performed in a hybrid room during a 30-month period. Patient medical records were retrospectively reviewed for evidence of skin injury. Patients were seen in follow-up daily until discharge and then at weeks 2 and 6, months 3 and 6, and 1 year. Phone interviews were conducted to determine the presence of any skin-related complaints. Peak skin dose (PSD) distributions were calculated for FEVARs with custom software employing input data from fluoroscopic machine logs. These calculations were validated against Gafchromic film (Ashland Inc, Covington, Ky) measurements. Dose was summed for the subset of patients with multiple procedures within 6 months of the SRDL event, consistent with Joint Commission recommendations. RESULTS Sixty-one CEPs reached a reference air kerma (RAK) of 5 Gy (50 FEVARs, six embolizations, one thoracic endovascular aortic repair, one endovascular aneurysm repair, one carotid intervention, and two visceral interventions). The patient cohort was 79% male and had a mean body mass index of 31. The average RAK was 8 ± 2 Gy (5.0-15.9 Gy). Sixteen patients had multiple CEPs within 6 months of the SRDL event, with a mean cumulative RAK of 12 ± 3 Gy (7.0-18.4 Gy). The mean FEVAR PSD was 6.6 ± 3.6 Gy (3.7-17.8 Gy), with a mean PSD/RAK ratio of 0.78. Gafchromic film dose measurements were not statistically different from PSD estimations, with a constant of proportionality of 0.99. Three patients were lost to follow-up before their first postoperative visit. No radiation skin injuries were found. CONCLUSIONS This study represents the largest analysis of deterministic skin injury after CEPs, and our results suggest that it is less frequent than expected and not increased in CEPs.

[1]  Saint Louis,et al.  American Association of Physicists in Medicine , 2014 .

[2]  J. Galvin,et al.  Radiochromic film dosimetry: recommendations of AAPM Radiation Therapy Committee Task Group 55. American Association of Physicists in Medicine. , 1998, Medical physics.

[3]  C. McKinstry,et al.  Absorbed dose and deterministic effects to patients from interventional neuroradiology. , 2000, The British journal of radiology.

[4]  A. Hanlon,et al.  Diabetes mellitus: a predictor for late radiation morbidity. , 1999, International journal of radiation oncology, biology, physics.

[5]  Stephen Balter,et al.  Comparison of four techniques to estimate radiation dose to skin during angiographic and interventional radiology procedures. , 2002, Journal of vascular and interventional radiology : JVIR.

[6]  L. Michalis,et al.  Radiation burden of patients undergoing endovascular abdominal aortic aneurysm repair. , 2009, Journal of vascular surgery.

[7]  F. Mettler,et al.  Skin injuries from fluoroscopically guided procedures: part 1, characteristics of radiation injury. , 2001, AJR. American journal of roentgenology.

[8]  E L Siegel,et al.  Severe skin reactions from interventional fluoroscopy: case report and review of the literature. , 1999, Radiology.

[9]  Stephen Balter,et al.  Minimizing radiation-induced skin injury in interventional radiology procedures. , 2002, Radiology.

[10]  G. Arbique,et al.  Surgeon education decreases radiation dose in complex endovascular procedures and improves patient safety. , 2013, Journal of vascular surgery.

[11]  D. Slovut Cutaneous radiation injury after complex coronary intervention. , 2009, JACC. Cardiovascular interventions.

[12]  C. Fife,et al.  Radiation dermatitis: clinical presentation, pathophysiology, and treatment 2006. , 2006, Journal of the American Academy of Dermatology.

[13]  F. Mettler,et al.  Radiation injuries after fluoroscopic procedures. , 2002, Seminars in ultrasound, CT, and MR.

[14]  T. Mastracci,et al.  Factors affecting radiation injury. , 2011, Journal of vascular surgery.

[15]  Stephen Balter,et al.  Fluoroscopically guided interventional procedures: a review of radiation effects on patients' skin and hair. , 2010, Radiology.

[16]  F. Mettler Medical effects and risks of exposure to ionising radiation , 2012, Journal of Radiological Protection.

[17]  Donald L. Miller,et al.  Clinical radiation management for fluoroscopically guided interventional procedures. , 2010, Radiology.

[18]  S. Walsh,et al.  Ionizing Radiation in Endovascular Interventions , 2008, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[19]  Mahadevappa Mahesh,et al.  Radiation Dose Management for Fluoroscopically Guided Interventional Medical Procedures , 2012 .

[20]  Koichi Chida,et al.  The necessity of follow-up for radiation skin injuries in patients after percutaneous coronary interventions: radiation skin injuries will often be overlooked clinically , 2012, Acta radiologica.

[21]  K. Brown,et al.  Acute and chronic radiation injury. , 2011, Journal of vascular surgery.

[22]  F. Mettler,et al.  Radiation burns as a severe complication of fluoroscopically guided cardiological interventions. , 2004, Journal of interventional cardiology.

[23]  J I Ten,et al.  Skin radiation injuries in patients following repeated coronary angioplasty procedures. , 2001, The British journal of radiology.

[24]  F. Mettler,et al.  Skin injuries from fluoroscopically guided procedures: part 2, review of 73 cases and recommendations for minimizing dose delivered to patient. , 2001, AJR. American journal of roentgenology.