Electrogenerated chemiluminescence biosensor based on Ru(bpy)3(2+) and dehydrogenase immobilized in sol-gel/chitosan/poly(sodium 4-styrene sulfonate) composite material.

A new electrogenerated chemiluminescence biosensor was fabricated by immobilizing ECL reagent Ru(bpy)3(2+) and alcohol dehydrogenase in sol-gel/chitosan/poly(sodium 4-styrene sulfonate) (PSS) organically modified composite material. The component PSS was used to immobilize ECL reagent Ru(bpy)3(2+) by ion-exchange, while the addition of chitosan was to prevent the cracking of conventional sol-gel-derived glasses and provide biocompatible microenvironment for alcohol dehydrogenase. Such biosensor combined enzymatic selectivity with the sensitivity of ECL detection for quantification of enzyme substrate and it was much simpler than previous double-layer design. The detection limit was 9.3 x 10(-6) M for alcohol (S/N=3) with a linear range from 2.79 x 10(-5) to 5.78 x 10(-2) M. With ECL detection, the biosensor exhibited wide linear range, high sensitivity and good stability.

[1]  M. Kanungo,et al.  Electrochemically deposited sol-gel-derived silicate films as a viable alternative in thin-film design. , 2003, Analytical chemistry.

[2]  T. Nieman,et al.  Chemiluminescence biosensors using tris(2,2′-bipyridyl)ruthenium(II) and dehydrogenases immobilized in cation exchange polymers , 1997 .

[3]  Allen J. Bard,et al.  Polymer Films on Electrodes. 5. Electrochemistry and Chemiluminescence at Nafion-Coated Electrodes , 1981 .

[4]  J. Eijkel,et al.  A wireless electrochemiluminescence detector applied to direct and indirect detection for electrophoresis on a microfabricated glass device. , 2001, Analytical chemistry.

[5]  S. Dong,et al.  Amperometric glucose biosensor based on sol-gel organic-inorganic hybrid material. , 1998, Analytical chemistry.

[6]  Gang Wang,et al.  Amperometric hydrogen peroxide biosensor with sol-gel/chitosan network-like film as immobilization matrix. , 2003, Biosensors & bioelectronics.

[7]  Martín,et al.  Electrochemiluminescence of ruthenium (II) tris(bipyridine) encapsulated in sol-gel glasses , 2000, Analytical chemistry.

[8]  N. Danielson,et al.  Generation of chemiluminescence upon reaction of aliphatic amines with tris(2,2'-bipyridine)ruthenium(III) , 1987 .

[9]  Collinson,et al.  Electrogenerated chemiluminescence of tris (2,2'-bipyridyl)ruthenium(II) ion-exchanged in nafion-silica composite films , 2000, Analytical chemistry.

[10]  S. Tan,et al.  Amperometric hydrogen peroxide biosensor with silica sol-gel/chitosan film as immobilization matrix , 2001 .

[11]  T. Nieman,et al.  Chemiluminescence detection using regenerable tris(2,2'-bipyridyl)ruthenium(II) immobilized in Nafion. , 1992, Analytical chemistry.

[12]  J. Park,et al.  Determination of breath alcohol using a differential-type amperometric biosensor based on alcohol dehydrogenase , 1999 .

[13]  Yining Shi,et al.  Optically Transparent Polyelectrolyte−Silica Composite Materials: Preparation, Characterization, and Application in Optical Chemical Sensing , 1997 .

[14]  Ana M Azevedo,et al.  Ethanol biosensors based on alcohol oxidase. , 2005, Biosensors & bioelectronics.

[15]  Y. Obeng,et al.  Electrogenerated chemiluminescence. 53. Electrochemistry and emission from adsorbed monolayers of a tris(bipyridyl)ruthenium(II)-based surfactant on gold and tin oxide electrodes , 1991 .

[16]  M. L. Mena,et al.  Graphite-Teflon composite bienzyme amperometric biosensors for monitoring of alcohols. , 2003, Biosensors & bioelectronics.

[17]  I. Rubinstein,et al.  Electrogenerated chemiluminescence. 37. Aqueous ecl systems based on tris(2,2'-bipyridine)ruthenium(2+) and oxalate or organic acids , 1981 .

[18]  Shaojun Dong,et al.  Electrogenerated chemiluminescence biosensor with alcohol dehydrogenase and tris(2,2'-bipyridyl)ruthenium (II) immobilized in sol-gel hybrid material. , 2005, Biosensors & bioelectronics.

[19]  Donald R. Bobbitt,et al.  Role of electron-donating/withdrawing character, pH, and stoichiometry on the chemiluminescent reaction of tris(2,2'-bipyridyl)ruthenium(III) with amino acids , 1992 .

[20]  Shaojun Dong,et al.  Organically Modified Sol‐Gel/Chitosan Composite Based Glucose Biosensor , 2003 .

[21]  Shaojun Dong,et al.  Electrogenerated chemiluminescence from R(bpy)3(2+) ion-exchanged in carbon nanotube/perfluorosulfonated ionomer composite films. , 2004, Analytical chemistry.

[22]  Won-Yong Lee,et al.  Tris (2,2′-bipyridyl)ruthenium(II) electrogenerated chemiluminescence in analytical science , 1997 .

[23]  A. Bard,et al.  Electrogenerated chemiluminescent determination of oxalate. , 1983, Analytical chemistry.

[24]  S. Dong,et al.  Functionalized inorganic–organic composite material derivated by sol–gel for construction of mediated amperometric hydrogen peroxide biosensor , 1999 .

[25]  S. Forrest,et al.  Laser action in organic semiconductor waveguide and double-heterostructure devices , 1997, Nature.

[26]  C. Hsueh,et al.  Permselectivities and ion-exchange properties of organically modified sol-gel electrodes , 1997 .

[27]  Han Nim Choi,et al.  Sol-gel-immobilized Tris(2,2′-bipyridyl)ruthenium(II) electrogenerated chemiluminescence sensor for high-performance liquid chromatography , 2005 .

[28]  A. Bard,et al.  Scanning Electrochemical Microscopy. 37. Light Emission by Electrogenerated Chemiluminescence at SECM Tips and Their Application to Scanning Optical Microscopy , 1998 .

[29]  R. Engstrom,et al.  Characterization of electrode heterogeneity with electrogenerated chemiluminescence , 1987 .

[30]  S. Dong,et al.  Electrochemiluminescence of tris(2,2 '-bipyridyl)ruthenium (II) ion-exchanged in polyelectrolyte-silica composite thin-films , 2002 .

[31]  Jonathan K. Leland,et al.  Electrochemiluminescence-Based Quantitation of Classical Clinical Chemistry Analytes , 1996 .