Determinants of quantitative optic nerve measurements using spectral domain optical coherence tomography in a population-based sample of non-glaucomatous subjects.

PURPOSE To evaluate the ocular and systemic factors influencing measurements of optic nerve head (ONH) parameters and retinal nerve fiber layer (RNFL) thickness with spectral-domain optical coherence tomography (SD-OCT) in healthy Chinese adults. METHODS Adults ranging in age from 40 to 80 years were consecutively recruited from the population-based Singapore Chinese Eye Study. A SD-OCT instrument was used to measure ONH and RNFL parameters. A total of 542 eyes from 542 non-glaucomatous Chinese subjects were analyzed. Univariable and multiple linear regression analyses were performed to examine the effects of a range of ocular (e.g., intraocular pressure [IOP], axial length [AL], disc area) and systemic (e.g., blood pressure, serum glucose) factors on ONH and RNFL parameters. RESULTS In multiple regression analyses, neuroretinal rim area was independently associated with age (β = -0.006, P < 0.001), disc area (β = 0.183, P < 0.001), IOP (β = -0.009, P = 0.008), AL (β = -0.023, P = 0.004), and lens nuclear color (β = 0.042, P = 0.001). Vertical cup-to-disc ratio was independently correlated with age (β = 0.003, P < 0.001), disc area (β = 0.207, P < 0.001), IOP (β = 0.004, P = 0.014), AL (β = 0.010, P = 0.008), and lens nuclear color (β = -0.017, P = 0.006). Average RNFL thickness was independently related to age (β = -0.204, P = 0.001), disc area (β = 4.218, P < 0.001), signal strength (β = 1.348, P < 0.001), and AL (β = -1.332, P < 0.001). Disc area had the strongest effect on measurements of ONH parameters and RNFL thickness. CONCLUSIONS In a non-glaucomatous population, optic nerve measurements with SD-OCT vary with disc area, age, IOP, AL, lens nuclear color, and signal strength, but systemic parameters have little influence. This information may be useful for interpretation of SD-OCT measurements.

[1]  Teresa C. Chen,et al.  In vivo human retinal imaging by ultrahigh-speed spectral domain optical coherence tomography. , 2004, Optics letters.

[2]  Luke Vale,et al.  Screening for Open Angle Glaucoma: Systematic Review of Cost-effectiveness Studies , 2008, Journal of glaucoma.

[3]  J. Fujimoto,et al.  Optical Coherence Tomography , 1991, LEOS '92 Conference Proceedings.

[4]  J. Newell,et al.  Mathematical coupling of data: correction of a common error for linear calculations. , 1986, Journal of applied physiology.

[5]  P. Mitchell,et al.  Influence of height, weight, and body mass index on optic disc parameters. , 2010, Investigative ophthalmology & visual science.

[6]  Tin Aung,et al.  Determinants of the optic cup to disc ratio in an Asian population: the Singapore Malay Eye Study (SiMES). , 2008, Archives of ophthalmology.

[7]  Douglas R. Anderson,et al.  Ability of cirrus HD-OCT optic nerve head parameters to discriminate normal from glaucomatous eyes. , 2011, Ophthalmology.

[8]  J Katz,et al.  A population-based evaluation of glaucoma screening: the Baltimore Eye Survey. , 1991, American journal of epidemiology.

[9]  Donald L Budenz,et al.  Symmetry between the right and left eyes of the normal retinal nerve fiber layer measured with optical coherence tomography (an AOS thesis). , 2008, Transactions of the American Ophthalmological Society.

[10]  C Bunce,et al.  The morphology of the optic nerve head in the Singaporean Chinese population (the Tanjong Pagar study): part 2—biometric and systemic associations , 2008, British Journal of Ophthalmology.

[11]  J. Duker,et al.  Three-dimensional retinal imaging with high-speed ultrahigh-resolution optical coherence tomography. , 2005, Ophthalmology.

[12]  Paul Mitchell,et al.  Symmetry of optical coherence tomography retinal measurements in young children. , 2007, American journal of ophthalmology.

[13]  P. Mitchell,et al.  Methodology of the Singapore Indian Chinese Cohort (SICC) Eye Study: Quantifying ethnic variations in the epidemiology of eye diseases in Asians , 2009, Ophthalmic epidemiology.

[14]  J. Jonas,et al.  Effect of arterial hypertension on the optic disc structure. , 1996, Archives of ophthalmology.

[15]  N. Congdon,et al.  Screening and managing eye disease in 2010: an Asian perspective. , 2010, American journal of ophthalmology.

[16]  Joel S Schuman,et al.  Optic nerve head and retinal nerve fiber layer analysis: a report by the American Academy of Ophthalmology. , 2007, Ophthalmology.

[17]  A. Hofman,et al.  Determinants of optic disc characteristics in a general population: The Rotterdam Study. , 1999, Ophthalmology.

[18]  F. Medeiros,et al.  Influence of disease severity and optic disc size on the diagnostic performance of imaging instruments in glaucoma. , 2006, Investigative ophthalmology & visual science.

[19]  J P Archie,et al.  Mathematic Coupling of Data: A Common Source of Error , 1981, Annals of surgery.

[20]  J. Schuman,et al.  Optical coherence tomography. , 2000, Science.

[21]  F. Horn,et al.  Retinal Nerve Fiber Layer Thickness in Normals Measured by Spectral Domain OCT , 2010, Journal of glaucoma.

[22]  A. Coleman,et al.  Association of blood pressure status with the optic disk structure in non-glaucoma subjects: the Thessaloniki eye study. , 2006, American journal of ophthalmology.

[23]  R Varma,et al.  Retinal nerve fiber layer thickness in normal human eyes. , 1996, Ophthalmology.

[24]  F. Medeiros,et al.  Effect of disease severity and optic disc size on diagnostic accuracy of RTVue spectral domain optical coherence tomograph in glaucoma. , 2011, Investigative ophthalmology & visual science.

[25]  Harsha L Rao,et al.  Predictors of normal optic nerve head, retinal nerve fiber layer, and macular parameters measured by spectral domain optical coherence tomography. , 2011, Investigative ophthalmology & visual science.

[26]  C. Cheung,et al.  Retinal nerve fiber layer measurements in myopia: An optical coherence tomography study. , 2006, Investigative ophthalmology & visual science.

[27]  U. P. S. T. Force Screening for Glaucoma: Recommendation Statement , 2005 .

[28]  T. Wong,et al.  Rationale and Methodology for a Population-Based Study of Eye Diseases in Malay People: The Singapore Malay Eye Study (SiMES) , 2007, Ophthalmic epidemiology.

[29]  Joel S Schuman,et al.  Optic Nerve Head (ONH) Topographic Analysis by Stratus OCT in Normal Subjects: Correlation to Disc Size, Age, and Ethnicity , 2009, Journal of glaucoma.

[30]  C. Cheung,et al.  Relationship between retinal nerve fiber layer measurement and signal strength in optical coherence tomography. , 2008, Ophthalmology.

[31]  Douglas R. Anderson,et al.  Determinants of normal retinal nerve fiber layer thickness measured by Stratus OCT. , 2007, Ophthalmology.

[32]  A. Iwase,et al.  Laser scanning tomography of optic discs of the normal Japanese population in a population-based setting. , 2009, Ophthalmology.

[33]  Tin Aung,et al.  The prevalence and types of glaucoma in malay people: the Singapore Malay eye study. , 2008, Investigative ophthalmology & visual science.

[34]  K. A. Townsend,et al.  Effects of age on optical coherence tomography measurements of healthy retinal nerve fiber layer, macula, and optic nerve head. , 2009, Ophthalmology.

[35]  M. C. Leske,et al.  The Lens Opacities Classification System III. The Longitudinal Study of Cataract Study Group. , 1993, Archives of ophthalmology.

[36]  V. Moyer,et al.  Screening for Glaucoma: U.S. Preventive Services Task Force Recommendation Statement , 2013, Annals of Internal Medicine.

[37]  Robert N. Weinreb,et al.  Retinal nerve fiber layer imaging with spectral-domain optical coherence tomography: a variability and diagnostic performance study. , 2010, Ophthalmology.

[38]  M. C. Leske,et al.  The Lens Opacities Classification System III , 1993 .

[39]  Paul Harasymowycz,et al.  Screening for glaucoma in high-risk populations using optical coherence tomography. , 2009, Ophthalmology.