An in-phantom dosimetry system using pin silicon photodiode radiation sensors for measuring organ doses in x-ray CT and other diagnostic radiology.

A dosimetry system using commercially available pin silicon photodiodes as the sensor is evaluated for in-phantom dose measurements in x-ray CT and other diagnostic radiology. System sensitivity measured as a function of the effective energy of x rays was between 0.37 and 0.49 V/mGy at an effective energy range between 23.5 and 72 keV. The minimum detectable organ dose with 25% uncertainty was estimated to be 0.02 mGy. The excellent output linearity was found over a dose range from 0.03 to more than 10 mGy with flat dose rate response of system sensitivity up to 35 mGy s(-1), though the sensitivity indicated some energy dependence across the diagnostic energy range with a maximum of about 10%/10 keV. Since angular dependence of the sensitivity of the photodiode sensor was found to be small enough it would induce negligible dose error. Dose profile measurement along the axis of a thoracic phantom undergoing CT chest examination indicated the reliability of dose values over a range of two orders of magnitude from less than 0.2 to 12 mGy. The present dosimetry system having advantages of high sensitivity with immediate readout of dose values, low cost, and easy construction would widely be used as an alternative to TLD dosimeters for organ and skin dose measurements in CT and other diagnostic radiology.

[1]  C. Furetta,et al.  On the use of pediatric phantoms in the dose evaluation during computed tomography (CT) thorax examinations. , 2001, Medical physics.

[2]  F. H. Attix Introduction to Radiological Physics and Radiation Dosimetry , 1991 .

[3]  K. Nishizawa,et al.  [Estimation of effective dose from CT examination]. , 1995, Nihon Igaku Hoshasen Gakkai zasshi. Nippon acta radiologica.

[4]  Stenstrom Kw,et al.  Ionization measurements with bone chambers and their application to radiation therapy. , 1946 .

[5]  M. Zankl Methods for Assessing Organ Doses using Computational Models , 1998 .

[6]  P. Vock,et al.  Radiation exposure of patients who undergo CT of the trunk. , 1995, Radiology.

[7]  C H McCollough,et al.  Calculation of effective dose. , 2000, Medical physics.

[8]  D. Peet,et al.  Evaluation of a MOSFET radiation sensor for the measurement of entrance surface dose in diagnostic radiology. , 1999, The British journal of radiology.

[9]  M Caon,et al.  A comparison of radiation dose measured in CT dosimetry phantoms with calculations using EGS4 and voxel-based computational models. , 1997, Physics in medicine and biology.

[10]  K Aoki,et al.  A silicon diode in a thimble-type mount for measurement of diagnostic x-ray spectra. , 1990, Physics in medicine and biology.

[11]  J. H. Hubbell,et al.  Tables of X-Ray Mass Attenuation Coefficients and Mass Energy-Absorption Coefficients 1 keV to 20 MeV for Elements Z = 1 to 92 and 48 Additional Substances of Dosimetric Interest , 1995 .

[12]  Gad Shani,et al.  Radiation Dosimetry Instrumentation and Methods , 1991 .

[13]  西沢 かな枝,et al.  X線診断による臓器・組織線量, 実効線量および集団実効線量 , 1996 .

[14]  G. Hettinger,et al.  Scattered radiation in a water phantom irradiated by roentgen photons between 50 and 250 ke V. , 1960, Acta radiologica.

[15]  Y. Onai,et al.  TRIAL PRODUCTION OF A WATER-EQUIVALENT SOLID PHANTOM MATERIAL , 1959 .

[16]  S B Herdade,et al.  Determination of the voltage applied to x-ray tubes from the bremsstrahlung spectrum obtained with a silicon PIN photodiode. , 2000, Medical physics.

[17]  J. Felsteiner,et al.  Low energy X-ray and γ spectroscopy using silicon pin photodiodes , 1988 .