Computational Fluid Dynamics Calibration of Tattersall Mk-II Type Rheometer for Concrete

Abstract Currently more and more researches have been performing concerning the numerical simulation of the behavior of fresh concrete during pumping or formwork filling. Adequate implementation of the rheology properties of fresh concrete is a determinant key to obtain realistic simulations. However, in many cases, the rheological parameters of the fresh concrete as determined by rheometers are not sufficiently accurate. The common principle of all the rheometers is not to measure directly the rheological parameters of concrete but to measure some basic physical parameters (torque, velocity, pressure, …) that that in some cases allow the calculation of the rheological parameter in terms of fundamental physical quantities. Errors can be caused by undesired flow phenomena which are not taken into the prediction formulas and by the inaccurate prediction formulas themselves. This is directly related to the poor calibration of the rheometer that cannot cover all ranges of materials. This paper investigates the calibration of the Tattersall MK-II rheometer by performing the numerical simulation for a tremendous range of concrete flowing in the rheometer, using computational fluid dynamics (CFD). This allows to quickly and accurately obtain the rheological properties of fresh concrete, which can then be used consistently for further flow simulations. This method can be applied for all types of rheometer.

[1]  Peter Domone,et al.  Comparison of concrete rheometers: international tests at LCPC (Nantes, France) in October 2000, NISTIR 6819 , 2001 .

[2]  Thierry Sedran,et al.  Validation of BTRHEOM, the new rheometer for soft-to-fluid concrete , 1996 .

[3]  L. A. Pereira de Oliveira,et al.  The Influence of Wastes Materials on the Rheology of Rendering Mortars , 2013 .

[4]  J. Labrincha,et al.  Effect of Lightweight Aggregates Addition on the Rheological Properties and the Hardened State of Mortars , 2011 .

[5]  G. de Schutter,et al.  Evaluation of Time Independent Rheological Models Applicable to Fresh Self-Compacting Concrete , 2007 .

[6]  H. Barnes,et al.  An introduction to rheology , 1989 .

[7]  Geert De Schutter,et al.  Why is fresh self-compacting concrete shear thickening? , 2009 .

[8]  Christopher W. Macosko,et al.  Rheology: Principles, Measurements, and Applications , 1994 .

[9]  Roger I. Tanner,et al.  Rheology : an historical perspective , 1998 .

[10]  W. Jau,et al.  Development of a modified concrete rheometer to measure the rheological behavior of conventional and self-consolidating concretes , 2010 .

[11]  H. Eyring,et al.  Deformation and flow : an elementary introduction to theoretical rheology , 1950 .

[12]  Ammar Yahia,et al.  Extension of the Reiner–Riwlin equation to determine modified Bingham parameters measured in coaxial cylinders rheometers , 2013 .

[13]  Christophe Lanos,et al.  High Torque Vane Rheometer for Concrete: Principle and Validation from Rheological Measurements , 2012 .

[14]  Kamal H. Khayat,et al.  Analytical models for estimating yield stress of high-performance pseudoplastic grout , 2001 .

[15]  G. H. Tattersall,et al.  Further development of the two-point test for workability and extension of its range , 1979 .

[16]  Phillip Frank Gower Banfill,et al.  Rheology of fresh cement and concrete , 1991 .

[17]  G. H. Tattersall,et al.  The rationale of a two-point workability test , 1973 .

[18]  Y. Leong Yeow,et al.  Solving the inverse problem of Couette viscometry by Tikhonov regularization , 2000 .

[19]  Christophe Ancey,et al.  Solving the Couette inverse problem using a wavelet-vaguelette decomposition , 2005 .

[20]  Dimitri Feys Interactions between rheological properties and pumping of self-compacting concrete , 2009 .