Spray Characterization of Thermal Fogging Equipment Typically Used in Vector Control1

ABSTRACT Droplet size spectra from different sprayers used to generate insecticide-laden fogs for controlling flying insects were measured by a laser diffraction instrument and Teflon-coated slides. The objectives of this work were to present not only information on spray-system droplet size generated by different sprayers, but to compare methodologies by which other similar systems can be evaluated and give applicators sprayer-system performance data. Data from 45 replicated spray tests, comprising 11 sprayers and 5 pesticides, showed a wide range in the droplet size spectra produced. The volume median diameter measurements ranged from 2.6 to 75.5 μm for diesel-diluted sprays and from 27.9 to 59.9 μm for water-diluted sprays. Similarly, the percent volume <20 μm ranged between 12.0–100% and 8.5–30.7%, for diesel- and water-diluted sprays, respectively. The droplet sizes measured by the swinging slide and laser diffraction methods were not consistent. The information presented aids users in sprayer selection and operation to produce the specific droplet size spectra required for a particular application.

[1]  Daniel E. Martin,et al.  DROPLET-SIZE CHARACTERIZATION OF HANDHELD ATOMIZATION EQUIPMENT TYPICALLY USED IN VECTOR CONTROL1 , 2007, Journal of the American Mosquito Control Association.

[2]  W. C. Hoffmann,et al.  CHARACTERIZATION OF TRUCK-MOUNTED ATOMIZATION EQUIPMENT TYPICALLY USED IN VECTOR CONTROL1 , 2007, Journal of the American Mosquito Control Association.

[3]  H. L. Lee,et al.  Thermal application of Bacillus thuringiensis serovar israelensis for dengue vector control. , 2001, Journal of vector ecology : journal of the Society for Vector Ecology.

[4]  J. R. Brown,et al.  Temperature and flow rate effects on mass median diameters of thermally generated malathion and naled fogs. , 1993, Journal of the American Mosquito Control Association.

[5]  S. Jordan,et al.  Effects of ultra-low volume and thermal fog malathion, Scourge and naled applied against caged adult Culicoides furens and Culex quinquefasciatus in open and vegetated terrain. , 1992, Journal of the American Mosquito Control Association.

[6]  K. R. May,et al.  The Impaction of Aerosol Particles on Cylinders, Spheres, Ribbons and Discs , 1967 .

[7]  J. Henderson Ground Equipment and Insecticides for Mosquito Control , 1952 .

[8]  T. Mabbett Fogged protection for food on the move , 2004 .

[9]  R. Rose Pesticides and public health: integrated methods of mosquito management. , 2001, Emerging infectious diseases.

[10]  M. Ledson Droplet spectra with thermal foggers , 1992 .

[11]  V. Ezike,et al.  Ground application of malathion thermal fogs and cold mists for the control of sylvatic vectors of yellow fever in rural communities near Enugu, Nigeria. , 1980 .

[12]  Graham Matthews,et al.  Pesticide application methods , 1979 .

[13]  C. Rathburn,et al.  Ultra low volume tests of malathion applied by ground equipment for the control of adult mosquitoes. , 1972 .

[14]  R. Taylor,et al.  The relative effectiveness of malathion thermal aerosols and ground-applied ULV against three species of mosquitoes. , 1971 .

[15]  Rathburn Methods of assessing droplet size of insecticidal sprays and fogs. , 1970 .

[16]  Clements,et al.  Comparative tests of fog oils and diesel oil as thermal aerosols for control of adult mosquitoes. , 1965 .