Robust common carotid artery lumen detection in B-mode ultrasound images using local phase symmetry

This paper presents a new method for automatic common carotid artery detection in B-mode ultrasonography. The proposed method is based on the location of phase symmetry patterns at apropriate scale of analysis. The local phase information is derived from the monogenic signal and isotropic log-normal band-pass filters, and the resulting common carotid artery is located using a dynamic programming optimization algorithm. The experiments show that the proposed method is more robust to noise than previous approaches, although additional research is required for robust common carotid artery detection on the more complicated cases.

[1]  Jasjit S. Suri,et al.  AUTOMATIC COMPUTER-BASED TRACINGS (ACT) IN LONGITUDINAL 2-D ULTRASOUND IMAGES USING DIFFERENT SCANNERS , 2009 .

[2]  Alessandro C. Rossi,et al.  Automatic recognition of the common carotid artery in longitudinal ultrasound B-mode scans , 2008, Medical Image Anal..

[3]  J. Suri,et al.  An Integrated Approach to Computer‐Based Automated Tracing and Its Validation for 200 Common Carotid Arterial Wall Ultrasound Images , 2010, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[4]  E. Vicaut,et al.  Mannheim Carotid Intima-Media Thickness Consensus (2004–2006) , 2006, Cerebrovascular Diseases.

[5]  Tomas Gustavsson,et al.  A multiscale dynamic programming procedure for boundary detection in ultrasonic artery images , 2000, IEEE Transactions on Medical Imaging.

[6]  Michael Felsberg,et al.  The monogenic signal , 2001, IEEE Trans. Signal Process..

[7]  U. Rajendra Acharya,et al.  Completely Automated Multiresolution Edge Snapper—A New Technique for an Accurate Carotid Ultrasound IMT Measurement: Clinical Validation and Benchmarking on a Multi-Institutional Database , 2012, IEEE Transactions on Image Processing.

[8]  Jasjit S. Suri,et al.  A state of the art review on intima-media thickness (IMT) measurement and wall segmentation techniques for carotid ultrasound , 2010, Comput. Methods Programs Biomed..

[9]  Aurélio J. C. Campilho,et al.  Automatic segmentation of carotid B-mode images using fuzzy classification , 2012, Medical & Biological Engineering & Computing.

[10]  T. Loupas,et al.  An adaptive weighted median filter for speckle suppression in medical ultrasonic images , 1989 .

[11]  Aurélio J. C. Campilho,et al.  Segmentation of the carotid intima-media region in B-mode ultrasound images , 2010, Image Vis. Comput..