Clinical influences on bone cement monomer release.

Monomer losses for two self-curing acrylic cements were similar via laboratory serial weighing experiments. Both the P/L ratio and mixing duration substantially influenced subsequent monomer losses, but ambient temperature variation during mixing had little effect. Greater losses were encountered during the mixing and setting intervals than during the molding interval. Patient potential exposure to monomer occurs during the molding and setting intervals; therefore, handling procedures reducing losses in these intervals are important to the surgeon. The least monomer loss during both molding and setting occurred at the manufacturers' recommended P/L ratio, which strongly indicated the need to mix all contents supplied. Mixing loss increased with amount of spatulation. However, once the mass was well mixed (about 300 steady spatulations), no further decreases in the molding and setting interval losses were promoted by overmixing. Because of the lower monomer loss rate during the molding interval, postponed cement insertion may not be warranted in light of losing mechanical locking efficiency. The actual ramifications of a threefold reduction in potential patient exposure (3.5 down to 1.2 wt% of total monomer) via modified handling techniques have not yet been clinically evaluated.

[1]  C. Compere,et al.  Degree of polymerization of acrylic bone cement. , 2004, Journal of biomedical materials research.

[2]  C. Difazio,et al.  Blood clearance and acute pulmonary toxicity of methylmethacrylate in dogs after simulated arthroplasty and intravenous injection. , 1973, The Journal of bone and joint surgery. American volume.

[3]  E. Lautenschlager,et al.  On the setting properties of acrylic bone cement. , 1973, The Journal of bone and joint surgery. American volume.

[4]  D. Dandy,et al.  Acrylic cement and fat embolism. , 1972, British medical journal.

[5]  M. L. James,et al.  Cardiovascular responses after methylmethacrylic cement. , 1972, British medical journal.

[6]  R. Volz,et al.  Severe hypotension during prosthetic hip surgery with acrylic bone cement. , 1972, Anesthesiology.

[7]  T. C. Smith,et al.  The intraoperative hazard of acrylic bone cement: report of a case. , 1971, Anesthesiology.

[8]  A. Lettin,et al.  Cardiovascular Effects of Implanted Acrylic Bone Cement , 1971, British medical journal.

[9]  T. A. Thomas,et al.  Cold curing acrylic bone cement , 1971, Anaesthesia.

[10]  J. K. Haken,et al.  COLD–CURING CEMENTS IN ORTHOPAEDIC SURGERY , 1971, The Medical journal of Australia.

[11]  Amstutz Hc Complications of total hip replacement. , 1970, Clinical orthopaedics and related research.

[12]  J. K. Haken,et al.  28 Evaluation of Cold‐curing Acrylic Cement for Prosthesis Stabilization , 1970, Clinical orthopaedics and related research.

[13]  S. Lahiri,et al.  Cardiac arrest associated with bone cement. , 1970, British medical journal.

[14]  H. Tullos,et al.  Evaluation of rapid-cure acrylic compound for prosthesis stabilization. , 1969, Clinical orthopaedics and related research.