Indoor Air in Beauty Salons and Occupational Health Exposure of Cosmetologists to Chemical Substances

The indoor environment in four beauty salons located in Athens (Greece) was examined in order to investigate the occupational health exposure of cosmetologists to various chemical products typically used in their work. Chemical substances chosen for investigation were volatile organic compounds (VOCs), formaldehyde, ozone and carbon dioxide. Total VOCs levels measured showed significant variation (100–1,450 μg m−3) depending on the products used and the number of treatments carried out, as well as ventilation. The main VOCs found in the salons were aromatics (toluene, xylene), esters and ketones (ethyl acetate, acetone, etc.) which are used as solvents in various beauty products; terpenes (pinene, limonene, camphor, menthenol) which have a particular odor and others like camphor which have specific properties. Ozone concentrations measured in all salons were quite low (0.1 and 13.3 μg m−3) and formaldehyde concentrations detected were lower than the detection limit of the method in all salons (<0.05 ppm). Carbon dioxide levels ranged between 402 and 1,268 ppm, depending on the number of people present in the salons during measurements and ventilation. Cosmetologists may be exposed to high concentrations of a mixture of volatile organic compounds although these levels could be decreased significantly by following certain practices such as good ventilation of the areas, closing the packages of the beauty products when not in use and finally selecting safer beauty products without strong odor.

[1]  M. E. Meek,et al.  Inhaled Formaldehyde: Exposure Estimation, Hazard Characterization, and Exposure-Response Analysis , 2003, Journal of toxicology and environmental health. Part B, Critical reviews.

[2]  L. Rapport,et al.  Neurocognitive sequelae of exposure to organic solvents and (meth)acrylates among nail-studio technicians. , 2002, Neuropsychiatry, neuropsychology, and behavioral neurology.

[3]  E Sala,et al.  Occupational skin and respiratory diseases among hairdressers. , 1998, Scandinavian journal of work, environment & health.

[4]  B. Moen,et al.  Airborne exposure to chemical substances in hairdresser salons , 2009, Environmental monitoring and assessment.

[5]  J. Froines,et al.  Quantitative Evaluation of Manicurists Exposure to Methyl, Ethyl and Isobutyl Methacrylate During Production of Synthetic Fingernails , 1986 .

[6]  J. E. Janssen,et al.  Ventilation for acceptable indoor air quality , 1989 .

[7]  E. Alexopoulos,et al.  Case report: hydroquinone and/or glutaraldehyde induced acute myeloid leukaemia? , 2006, Journal of occupational medicine and toxicology.

[8]  S. Zencirci,et al.  Measurement of selected indoor physical environmental factors in hairdresser salons in a Turkish City , 2007, Environmental monitoring and assessment.

[9]  B. Samimi,et al.  Exposure of acrylic fingernail sculptors to organic vapors and methacrylate dusts. , 1987, American Industrial Hygiene Association journal.

[10]  Peder Wolkoff,et al.  Chemical, microbiological, health and comfort aspects of indoor air quality : state of the art in SBS , 1992 .

[11]  May‐Sen Lee,et al.  Adverse contact reactions to sculptured acrylic nails: 4 case reports and a literature review , 1995, Contact dermatitis.

[12]  France Labrèche,et al.  Characterization of chemical exposures in hairdressing salons. , 2003, Applied occupational and environmental hygiene.

[13]  L. Mølhave Human Reactions to Controlled Exposures to VOC’s and the “TOTAL-VOC” Concept , 1992 .

[14]  S. C. Sofuoglu,et al.  The Indoor Environmental Index and Its Relationship with Symptoms of Office Building Occupants , 2004, Journal of the Air & Waste Management Association.

[15]  B. Moen,et al.  Chemical exposure in hairdresser salons: effect of local exhaust ventilation. , 1998, The Annals of occupational hygiene.

[16]  K. Czene,et al.  Cancer risks in hairdressers: Assessment of carcinogenicity of hair dyes and gels , 2003, International journal of cancer.

[17]  D. Lezotte,et al.  Risk Factors for Asthma Among Cosmetology Professionals in Colorado , 2006, Journal of occupational and environmental medicine.

[18]  W. Gutenmann,et al.  Urinary mutagens in cosmetologists and dental personnel. , 1991, Journal of Toxicology and Environmental Health, Part A.

[19]  C. Chatzis,et al.  Indoor and outdoor personal exposure to benzene in Athens, Greece. , 2005, The Science of the total environment.

[20]  M. Gissler,et al.  Work as a hairdresser and cosmetologist and adverse pregnancy outcomes. , 2009, Occupational medicine.

[21]  Athena Linos,et al.  An analysis of factors that influence personal exposure to toluene and xylene in residents of Athens, Greece , 2006, BMC public health.

[22]  A. B. Spencer,et al.  Control of ethyl methacrylate exposures during the application of artificial fingernails. , 1997, American Industrial Hygiene Association journal.

[23]  L. Mølhave,et al.  Organic compounds as indicators of air pollution. , 2003, Indoor air.

[24]  G. Gattás,et al.  Assessment of occupational genotoxic risk among Brazilian hairdressers. , 2008, The Annals of occupational hygiene.

[25]  G. Abbritti,et al.  Indoor air quality and health in offices and other non-industrial working environments. , 2006, La Medicina del lavoro.

[26]  L. Folinsbee Human health effects of air pollution. , 1993, Environmental health perspectives.

[27]  Christina Holcroft,et al.  Results from a Community-based Occupational Health Survey of Vietnamese-American Nail Salon Workers , 2008, Journal of Immigrant and Minority Health.

[28]  H. Keskinen,et al.  Occupational respiratory disease caused by acrylates , 1993, Clinical and experimental allergy : journal of the British Society for Allergy and Clinical Immunology.

[29]  T. Leino,et al.  Working conditions and health in hairdressing salons. , 1999, Applied occupational and environmental hygiene.