An Oscillatory Stability Criterion Based on the Unified $dq$ -Frame Impedance Network Model for Power Systems With High-Penetration Renewables

Recent years have witnessed emerging oscillatory stability issues in power systems with high-penetration renewables. These issues are generally caused by the dynamic interaction between the AC/DC grid and power electronic converters used for the integration of renewables. Some previous studies have explored the issues with simplified system models containing only a few converters and idealized networks. However, the interactions between many converters and traditional generators/HVDCs have not been fully considered. To fill this gap, this paper first presents the concept of a unified dq frame impedance network model (INM), with which different converters as well as traditional generators/HVDCs can be incorporated to form an integrated s-domain model of a practical system. As the INM is aggregated into a lumped impedance matrix, a new criterion is then proposed to quantify the oscillatory stability, just by analyzing the frequency characteristics of the determinant of the matrix. Finally, the modeling method and the stability criterion are applied to a real-world system with a very high share of renewables and a realistic risk of oscillatory instability. Their effectiveness has been validated by both field measurements and electromagnetic transient simulations.

[1]  Daniel Belega,et al.  Dynamic Phasor and Frequency Measurements by an Improved Taylor Weighted Least Squares Algorithm , 2015, IEEE Transactions on Instrumentation and Measurement.

[2]  Frede Blaabjerg,et al.  An Active Damper for Stabilizing Power-Electronics-Based AC Systems , 2014 .

[3]  I. Canay A Novel Approach to the Torsional Interaction and Electrical Damping of the Synchronous Machine Part II: Application to an arbitrary network , 1982, IEEE Transactions on Power Apparatus and Systems.

[4]  Wenhua Liu,et al.  Multilevel MVDC Link Strategy of High-Frequency-Link DC Transformer Based on Switched Capacitor for MVDC Power Distribution , 2017, IEEE Transactions on Industrial Electronics.

[5]  Marta Molinas,et al.  Apparent impedance analysis: A new method for power system stability analysis , 2016, 2016 IEEE 17th Workshop on Control and Modeling for Power Electronics (COMPEL).

[6]  Frede Blaabjerg,et al.  Reactive Power Dispatch Method in Wind Farms to Improve the Lifetime of Power Converter Considering Wake Effect , 2017, IEEE Transactions on Sustainable Energy.

[7]  Zhao Yu,et al.  Subsynchronous Interaction Between Direct-Drive PMSG Based Wind Farms and Weak AC Networks , 2017, IEEE Transactions on Power Systems.

[8]  L. Harnefors,et al.  Analysis of Subsynchronous Torsional Interaction With Power Electronic Converters , 2007, IEEE Transactions on Power Systems.

[9]  Frede Blaabjerg,et al.  The Application of Vector Fitting to Eigenvalue-Based Harmonic Stability Analysis , 2017, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[10]  Massimo Bongiorno,et al.  Input-Admittance Calculation and Shaping for Controlled Voltage-Source Converters , 2007, IEEE Transactions on Industrial Electronics.

[11]  S. O. Faried,et al.  Utilizing DFIG-Based Wind Farms for Damping Subsynchronous Resonance in Nearby Turbine-Generators , 2013, IEEE Transactions on Power Systems.

[12]  Juri Jatskevich,et al.  A Multi-Decomposition Approach for Accelerated Time-Domain Simulation of Transient Stability Problems , 2015, IEEE Transactions on Power Systems.

[13]  Jing Huang,et al.  New Techniques for Measuring Impedance Characteristics of Three-Phase AC Power Systems , 2009, IEEE Transactions on Power Electronics.

[14]  Bo Wen,et al.  Impedance-Based Analysis of Grid-Synchronization Stability for Three-Phase Paralleled Converters , 2014, IEEE Transactions on Power Electronics.

[15]  Wei Liu,et al.  A Frequency-Based Synchronization Approach for the VSC-HVDC Station Connected to a Weak AC Grid , 2017, IEEE Transactions on Power Delivery.

[16]  Frede Blaabjerg,et al.  Couplings in Phase Domain Impedance Modeling of Grid-Connected Converters , 2016, IEEE Transactions on Power Electronics.

[17]  P. Kundur,et al.  Implementation of Advanced Generator Models into Power System Stability Programs , 1983, IEEE Transactions on Power Apparatus and Systems.

[18]  Marta Molinas,et al.  Understanding the Origin of Oscillatory Phenomena Observed Between Wind Farms and HVdc Systems , 2017, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[19]  R. Iravani,et al.  On the application of the complex torque coefficients method to the analysis of torsional dynamics , 2005, IEEE Transactions on Energy Conversion.

[20]  I. M. Canay,et al.  A Novel Approach to the Torsional Interaction and Electrical Damping of the Synchronous Machine Part I: Theory , 1982, IEEE Transactions on Power Apparatus and Systems.

[21]  Jun Liang,et al.  Positive-Net-Damping Stability Criterion in Grid-Connected VSC Systems , 2017, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[22]  Jian Sun,et al.  Impedance Modeling and Analysis of Grid-Connected Voltage-Source Converters , 2014, IEEE Transactions on Power Electronics.

[23]  Lennart Harnefors,et al.  Passivity-Based Controller Design of Grid-Connected VSCs for Prevention of Electrical Resonance Instability , 2015, IEEE Transactions on Industrial Electronics.

[24]  Liang Wang,et al.  Investigation of SSR in Practical DFIG-Based Wind Farms Connected to a Series-Compensated Power System , 2015, IEEE Transactions on Power Systems.

[25]  Vladimir Ceperic,et al.  A brief overview of the black-box behavioural modelling of electronic circuits for transient simulations , 2012, 2012 Proceedings of the 35th International Convention MIPRO.

[26]  A. Platzker,et al.  Rigorous determination of the stability of linear n-node circuits from network determinants and the appropriate role of the stability factor K of their reduced two-ports , 1994, Third International Workshop on Integrated Nonlinear Microwave and Millimeterwave Circuits.

[27]  Frede Blaabjerg,et al.  VSC Input-Admittance Modeling and Analysis Above the Nyquist Frequency for Passivity-Based Stability Assessment , 2017, IEEE Transactions on Industrial Electronics.

[28]  Hui Liu,et al.  Quantitative SSR Analysis of Series-Compensated DFIG-Based Wind Farms Using Aggregated RLC Circuit Model , 2017, IEEE Transactions on Power Systems.

[29]  Massimo Bongiorno,et al.  Stability Analysis of Two-Terminal VSC-HVDC Systems Using the Net-Damping Criterion , 2016, IEEE Transactions on Power Delivery.

[30]  Guangchao Geng,et al.  A Parallel Contour Integral Method for Eigenvalue Analysis of Power Systems , 2017, IEEE Transactions on Power Systems.

[31]  M. Belkhayat,et al.  Stability criteria for AC power systems with regulated loads , 1997 .

[32]  P. Kundur,et al.  Power system stability and control , 1994 .

[33]  Jorge A. Solsona,et al.  Sub-Synchronous Interaction Damping Control for DFIG Wind Turbines , 2015, IEEE Transactions on Power Systems.

[34]  Jinjun Liu,et al.  Infinity-Norm of Impedance-Based Stability Criterion for Three-Phase AC Distributed Power Systems With Constant Power Loads , 2015, IEEE Transactions on Power Electronics.

[35]  Lingling Fan,et al.  Mitigating SSR Using DFIG-Based Wind Generation , 2012, IEEE Transactions on Sustainable Energy.

[36]  Kai Strunz,et al.  Wind and Solar Power Integration in Electricity Markets and Distribution Networks Through Service-Centric Virtual Power Plants , 2018, IEEE Transactions on Power Systems.

[37]  Zhonghua Li,et al.  A Decomposition Method for the Total Leakage Current of MOA Based on Multiple Linear Regression , 2016, IEEE Transactions on Power Delivery.

[38]  Mohamed Shawky El Moursi,et al.  Subsynchronous Resonance Mitigation for Series-Compensated DFIG-Based Wind Farm by Using Two-Degree-of-Freedom Control Strategy , 2015, IEEE Transactions on Power Systems.

[39]  S. Chatterjee,et al.  Influential Observations, High Leverage Points, and Outliers in Linear Regression , 1986 .

[40]  Frede Blaabjerg,et al.  Passivity-Based Stability Assessment of Grid-Connected VSCs—An Overview , 2016, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[41]  Frede Blaabjerg,et al.  Unified Impedance Model of Grid-Connected Voltage-Source Converters , 2018, IEEE Transactions on Power Electronics.

[42]  Bo Wen,et al.  Analysis of D-Q Small-Signal Impedance of Grid-Tied Inverters , 2016, IEEE Transactions on Power Electronics.

[43]  Esmaeil Ebrahimzadeh,et al.  Harmonic Stability and Resonance Analysis in Large PMSG-Based Wind Power Plants , 2018, IEEE Transactions on Sustainable Energy.

[44]  Jian Sun,et al.  Impedance-Based Stability Criterion for Grid-Connected Inverters , 2011, IEEE Transactions on Power Electronics.

[45]  L Harnefors,et al.  Proof and Application of the Positive-Net-Damping Stability Criterion , 2011, IEEE Transactions on Power Systems.

[46]  D. Boroyevich,et al.  Black-Box Terminal Characterization Models for the Analysis and Simulation of Distributed Power Electronic Systems , 2007, 2007 IEEE Power Electronics Specialists Conference.

[47]  Xu Cai,et al.  A Modified Sequence-Domain Impedance Definition and Its Equivalence to the dq-Domain Impedance Definition for the Stability Analysis of AC Power Electronic Systems , 2016, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[48]  Frede Blaabjerg,et al.  Overview of Control and Grid Synchronization for Distributed Power Generation Systems , 2006, IEEE Transactions on Industrial Electronics.

[49]  Timothy C. Green,et al.  Dynamic Stability of a Microgrid With an Active Load , 2013, IEEE Transactions on Power Electronics.

[50]  Chongqing Kang,et al.  Managing Wind Power Uncertainty Through Strategic Reserve Purchasing , 2017, IEEE Transactions on Power Systems.

[51]  Jian Sun,et al.  Small-Signal Methods for AC Distributed Power Systems–A Review , 2009, IEEE Transactions on Power Electronics.