Label-free impedance detection of cancer cells.

Ovarian cancer cells, SKOV3, have been immobilized onto platinum microelectrodes using anti-EPCAM capture antibodies and detected with high sensitivity using electrochemical impedance. The change in impedance following cell capture is strongly dependent on the supporting electrolyte concentration. By controlling the concentration of Dulbecco's phosphate buffered saline (DPBS) electrolyte, the double layer thickness can be manipulated so that the interfacial electric field interacts with the bound cells, rather than simply decaying across the antibody capture layer. Significantly, the impedance changes markedly upon cell capture over the frequency range from 3 Hz to 90 kHz. For example, using an alternating-current (ac) amplitude of 25 mV, a frequency of 81.3 kHz, and an open circuit potential (OCP) as the direct-current (dc) voltage, a detection limit of 4 captured cells was achieved. Assuming an average cell radius of 5 μm, the linear dynamic range is from 4 captured cells to 650 ± 2 captured cells, which is approximately equivalent to fractional coverages from 0.1% to 29%. An equivalent circuit that models the impedance response of the cell capture is discussed.

[1]  M. Aepfelbacher,et al.  Electrical and optical characterization of thrombin-induced permeability of cultured endothelial cell monolayers on semiconductor electrode arrays , 2001 .

[2]  A. Bard,et al.  Immobilization and Hybridization of DNA on an Aluminum(III) Alkanebisphosphonate Thin Film with Electrogenerated Chemiluminescent Detection , 1995 .

[3]  Paul I. Okagbare,et al.  Highly efficient circulating tumor cell isolation from whole blood and label-free enumeration using polymer-based microfluidics with an integrated conductivity sensor. , 2008, Journal of the American Chemical Society.

[4]  Sarah Pönick,et al.  Impedance spectroscopy based measurement system for quantitative and label-free real-time monitoring of tauopathy in hippocampal slice cultures. , 2012, Biosensors & bioelectronics.

[5]  Neal J Meropol,et al.  Circulating tumor cells: evolving evidence and future challenges. , 2009, The oncologist.

[6]  Heinz-Georg Jahnke,et al.  A novel organotypic tauopathy model on a new microcavity chip for bioelectronic label-free and real time monitoring. , 2010, Biosensors & bioelectronics.

[7]  Anthony G. Frutos,et al.  Surface plasmon resonance imaging measurements of DNA hybridization adsorption and streptavidin/DNA multilayer formation at chemically modified gold surfaces , 1997 .

[8]  A. Blanchard,et al.  High-density oligonucleotide arrays , 1996 .

[9]  Mark E. Orazem,et al.  Electrochemical Impedance Spectroscopy: Orazem/Electrochemical , 2008 .

[10]  W. Everett,et al.  Factors that influence the stability of self-assembled organothiols on gold under electrochemical conditions , 1995 .

[11]  G. Johansson,et al.  Capacitance measurements of antibody-antigen interactions in a flow system. , 1997, Analytical chemistry.

[12]  Antonio Baldi,et al.  Label-free cancer cell detection with impedimetric transducers. , 2009, Analytical chemistry.

[13]  Alison Stopeck,et al.  Circulating tumor cells, disease progression, and survival in metastatic breast cancer. , 2004, The New England journal of medicine.

[14]  E. Alocilja,et al.  A high density microelectrode array biosensor for detection of E. coli O157:H7. , 2005, Biosensors & bioelectronics.

[15]  Maciej Zborowski,et al.  Rare cell separation and analysis by magnetic sorting. , 2011, Analytical chemistry.

[16]  N. Pourmand,et al.  Label-Free Impedance Biosensors: Opportunities and Challenges. , 2007, Electroanalysis.

[17]  S. P. Fodor,et al.  Multiplexed biochemical assays with biological chips , 1993, Nature.

[18]  Tomoko Yoshino,et al.  Size-selective microcavity array for rapid and efficient detection of circulating tumor cells. , 2010, Analytical chemistry.

[19]  Ruud H. Brakenhoff,et al.  Detection, clinical relevance and specific biological properties of disseminating tumour cells , 2008, Nature Reviews Cancer.

[20]  G. Johansson,et al.  An immunological interleukine-6 capacitive biosensor using perturbation with a potentiostatic step. , 1998, Biosensors & bioelectronics.

[21]  J. Therasse,et al.  Toxin detection using capacitance measurements on immunospecies grafted onto a semiconductor substrate , 1991 .

[22]  Miqin Zhang,et al.  Cellular impedance biosensors for drug screening and toxin detection. , 2007, The Analyst.

[23]  N. Jaffrezic‐Renault,et al.  Impedimetric measurements on polarized functionalized platinum electrodes: application to direct immunosensing , 1997 .

[24]  Robert J Hamers,et al.  Frequency-dependent electrical detection of protein binding events. , 2004, The Analyst.

[25]  Allen J. Bard,et al.  Electrochemical Methods: Fundamentals and Applications , 1980 .