STIFFENING EFFECT OF BOLT-ON TRANSDUCERS ON STRAIN MEASUREMENTS

The strain of a structural element is often measured indirectly by determining the strain of a transducer that is supposed to follow the deformation of the element perfectly, and with negligible interaction, around the mounting point. However, this assumption is not always true, and depends on the stiffness of the transducer relative to the local stiffness of the piece to which it is attached. This paper deals with the problem of evaluating the influence that a relatively rigid transducer (the HBM SLB-700A was chosen as an example) has on the strain field, studied from both the theoretical and the experimental points of view. The findings of the research have shown that, in order to interpret the measurements obtained from this kind of instruments correctly, the perturbation induced on the strain field cannot be disregarded. A corrective factor, obtained numerically by means of the FEM and discussed in the paper, can be used as a first approximation to evaluate the true strain, stress and forces in common structural steel elements.

[1]  E. G. Little,et al.  Strain gauge measurement , 1992 .

[2]  Bernardo Zuccarello,et al.  On the Stiffness and the Reinforcement Effect of Electrical Resistance Strain Gauges , 2005 .

[3]  V. M. Aleksandrov,et al.  Calculation of errors in strain-gauge measurements , 1966 .

[4]  W. N. Findley,et al.  Concerning strain-gage measurement of creep of plastics , 1963 .

[5]  J. W. Swan Resistance strain gauges on thermoplastics , 1973 .

[6]  Lars Pilgaard Mikkelsen,et al.  Correction of Gauge Factor for Strain Gauges Used in Polymer Composite Testing , 2014 .

[7]  Monica Barbero,et al.  The contribution of continuum-mechanics based numerical model to the design of debris flow barriers , 2014 .

[8]  P Stehlin,et al.  Strain distribution in and around strain gauges , 1972 .

[9]  H. Poulos,et al.  Elastic solutions for soil and rock mechanics , 1973 .

[10]  Marina Pirulli,et al.  Analisi dell'interazione tra colate detritiche e opere di difesa: il caso del torrente Grand Valey (Valle d'Aosta) , 2014 .

[11]  K. Lingaiah,et al.  Experimental stress analysis , 1984 .

[12]  Bernardo Zuccarello,et al.  Local Reinforcement Effect of a Strain Gauge Installation on Low Modulus Materials , 2005 .

[13]  Daniele Peila,et al.  Comportamento di una palificata prefabbricata per il contenimento delle terre: studi sperimentali , 2013 .

[14]  P. O'Donnell,et al.  Strain gauge reinforcement of plastics , 1990 .

[15]  Monica Barbero,et al.  Snow Pressure on a Semiflexible Retaining Structure , 2014 .

[16]  Millard F. Beatty,et al.  Numerical analysis of the reinforcement effect of a strain gage applied to a soft material , 1979 .

[17]  W R Campbell,et al.  Performance Tests of Wire Strain Gages V : Error in Indicated Bending Strains in Thin Sheet Metal Due to Thickness and Rigidity of Gage , 1947 .