Control Strategy for Three-Phase Grid-Connected Converters under Unbalanced and Distorted Grid Voltages Using Composite Observers

This paper proposes a novel scheme for the current controller for the grid-side converter (GSC) of permanent-magnet synchronous generator (PMSG) wind turbines to eliminate the high-order harmonics in the grid currents under grid voltage disturbances. The voltage unbalance and harmonics in three-phase systems cause grid current distortions. In order to mitigate the input current distortions, multi-loop current controllers are applied, where the positive-sequence component is regulated by proportional-integral (PI) controllers, and the negative-sequence and high-order harmonic components are regulated by proportional-resonance (PR) controllers. For extracting the positive/negative-sequence and harmonic components of the grid voltages and currents without a phase delay or magnitude reduction, composite observers are applied, which give faster and more precise estimation results. In addition, an active damping method using PR controllers to damp the grid current component of the resonant frequency is employed to improve the operating stability of VSCs with inductor-capacitor-inductor (LCL) filters. The validity of the proposed method is verified by simulation and experimental results.

[1]  Yan Zhou,et al.  Parameter Design of a Two-Current-Loop Controller Used in a Grid-Connected Inverter System With LCL Filter , 2009, IEEE Transactions on Industrial Electronics.

[2]  D. Boroyevich,et al.  Decoupled Double Synchronous Reference Frame PLL for Power Converters Control , 2007, IEEE Transactions on Power Electronics.

[3]  Dong-Choon Lee,et al.  A Fault Ride-Through Technique of DFIG Wind Turbine Systems Using Dynamic Voltage Restorers , 2011, IEEE Transactions on Energy Conversion.

[4]  Yow-Chyi Liu Improvement of Available Battery Capacity in Electric Vehicles , 2013 .

[5]  Dianguo Xu,et al.  Improved Grid Voltage Control Strategy for Wind Farms with DFIGs Connected to Distribution Networks , 2012 .

[6]  Yasser Abdel-Rady I. Mohamed,et al.  Mitigation of Dynamic, Unbalanced, and Harmonic Voltage Disturbances Using Grid-Connected Inverters With $LCL$ Filter , 2011, IEEE Transactions on Industrial Electronics.

[7]  Qiang Liu,et al.  New Control Strategy for Three-Phase Grid-Connected LCL Inverters without a Phase-Locked Loop , 2013 .

[8]  Marco Liserre,et al.  Filter-Based Active Damping of Voltage Source Converters With $LCL$ Filter , 2011, IEEE Transactions on Industrial Electronics.

[9]  Hong-Seok Song,et al.  Dual current control scheme for PWM converter under unbalanced input voltage conditions , 1999, IEEE Trans. Ind. Electron..

[10]  Seung-Ki Sul,et al.  Control of Electric Machine Drive Systems , 2011 .

[11]  Donald Grahame Holmes,et al.  Grid current regulation of a three-phase voltage source inverter with an LCL input filter , 2003 .

[12]  V. T. Ranganathan,et al.  A Method of Tracking the Peak Power Points for a Variable Speed Wind Energy Conversion System , 2002, IEEE Power Engineering Review.

[13]  Dong-Choon Lee,et al.  Feedback Linearization Control of Three-Phase UPS Inverter Systems , 2010, IEEE Transactions on Industrial Electronics.

[14]  Dong-Choon Lee,et al.  Sinusoidal Current Control of Single-Phase PWM Converters under Voltage Source Distortion Using Composite Observer , 2011 .

[15]  K. Selvajyothi,et al.  Extraction of Harmonics Using Composite Observers , 2008, IEEE Transactions on Power Delivery.

[16]  M. Liserre,et al.  Stability of photovoltaic and wind turbine grid-connected inverters for a large set of grid impedance values , 2006, IEEE Transactions on Power Electronics.

[17]  T.A. Lipo,et al.  Observer-Based Control Methods for Combined Source-Voltage Harmonics and Unbalance Disturbances in PWM Voltage-Source Converters , 2009, IEEE Transactions on Industry Applications.

[18]  Sergio Busquets-Monge,et al.  Control Strategies Based on Symmetrical Components for Grid-Connected Converters Under Voltage Dips , 2009, IEEE Transactions on Industrial Electronics.

[19]  Christian Wessels,et al.  Limitations of Voltage-Oriented PI Current Control of Grid-Connected PWM Rectifiers With $LCL$ Filters , 2009, IEEE Transactions on Industrial Electronics.

[20]  Amit K. Jain,et al.  Active Damping of Output $LC$ Filter Resonance for Vector-Controlled VSI-Fed AC Motor Drives , 2012, IEEE Transactions on Industrial Electronics.

[21]  Xinbo Ruan,et al.  Full Feedforward of Grid Voltage for Grid-Connected Inverter With LCL Filter to Suppress Current Distortion Due to Grid Voltage Harmonics , 2010, IEEE Transactions on Power Electronics.

[22]  Dong-Choon Lee,et al.  Control of three-phase grid converters based on composite observer for unbalanced and distorted grid voltage , 2012, 2012 IEEE International Symposium on Industrial Electronics.

[23]  K. Selvajyothi,et al.  Reduction of Voltage Harmonics in Single Phase Inverters Using Composite Observers , 2010, IEEE Transactions on Power Delivery.