Anthropometric Precision and Accuracy of Digital Three-Dimensional Photogrammetry: Comparing the Genex and 3dMD Imaging Systems with One Another and with Direct Anthropometry

A variety of commercially available three-dimensional (3D) surface imaging systems are currently in use by craniofacial specialists. Little is known, however, about how measurement data generated from alternative 3D systems compare, specifically in terms of accuracy and precision. The purpose of this study was to compare anthropometric measurements obtained by way of two different digital 3D photogrammetry systems (Genex and 3dMD) as well as direct anthropometry and to evaluate intraobserver precision across these three methods. On a sample of 18 mannequin heads, 12 linear distances were measured twice by each method. A two-factor repeated measures analysis of variance was used to test simultaneously for mean differences in precision across methods. Additional descriptive statistics (e.g., technical error of measurement [TEM]) were used to quantify measurement error magnitude. Statistically significant (P < 0.05) mean differences were observed across methods for nine anthropometric variables; however, the magnitude of these differences was consistently at the submillimeter level. No significant differences were noted for precision. Moreover, the magnitude of imprecision was determined to be very small, with TEM scores well under 1 mm, and intraclass correlation coefficients ranging from 0.98 to 1. Results indicate that overall mean differences across these three methods were small enough to be of little practical importance. In terms of intraobserver precision, all methods fared equally well. This study is the first attempt to simultaneously compare 3D surface imaging systems directly with one another and with traditional anthropometry. Results suggest that craniofacial surface data obtained by way of alternative 3D photogrammetric systems can be combined or compared statistically.

[1]  Kristina Aldridge,et al.  Precision and error of three‐dimensional phenotypic measures acquired from 3dMD photogrammetric images , 2005, American journal of medical genetics. Part A.

[2]  S. Weinberg,et al.  Three-dimensional surface imaging: limitations and considerations from the anthropometric perspective. , 2005, The Journal of craniofacial surgery.

[3]  Albert Losken,et al.  Validating Three-Dimensional Imaging of the Breast , 2005, Annals of plastic surgery.

[4]  A. Ayoub,et al.  Methods of Assessment of Cleft-Related Facial Deformity: A Review , 2005, The Cleft palate-craniofacial journal : official publication of the American Cleft Palate-Craniofacial Association.

[5]  Mary L Marazita,et al.  Digital Three-Dimensional Photogrammetry: Evaluation of Anthropometric Precision and Accuracy Using a Genex 3D Camera System , 2004, The Cleft palate-craniofacial journal : official publication of the American Cleft Palate-Craniofacial Association.

[6]  A F Ayoub,et al.  Applications of 3D Imaging in Orthodontics: Part I , 2004, Journal of orthodontics.

[7]  C. A. Hood,et al.  Validation of a Vision-Based, Three-Dimensional Facial Imaging System , 2003, The Cleft palate-craniofacial journal : official publication of the American Cleft Palate-Craniofacial Association.

[8]  N. Philip,et al.  Comparison between direct clinical and digital photogrammetric measurements in patients with 22q11 microdeletion. , 2003, International journal of oral and maxillofacial surgery.

[9]  L. Farkas,et al.  Relation Between Anthropometric and Cephalometric Measurements and Proportions of the Face of Healthy Young White Adult Men and Women , 2003, The Journal of craniofacial surgery.

[10]  C L Vaughan,et al.  A stereo-photogrammetric method to measure the facial dysmorphology of children in the diagnosis of fetal alcohol syndrome. , 2002, Medical engineering & physics.

[11]  C. Landes,et al.  Introduction of a three-dimensional anthropometry of the viscerocranium. Part I: measurement of craniofacial development and establishment of standard values and growth functions. , 2002, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.

[12]  D. Kerr,et al.  Anthropometric measurement error and the assessment of nutritional status , 1999, British Journal of Nutrition.

[13]  S. Ong,et al.  Surface laser scanning of the cleft palate deformity--validation of the method. , 1999, Annals of the Academy of Medicine, Singapore.

[14]  Aung Sc The role of laser surface imaging in the evaluation of craniomaxillofacial disorders: the Singapore General Hospital experience. , 1999 .

[15]  L. Farkas,et al.  Digital two-dimensional photogrammetry: a comparison of three techniques of obtaining digital photographs. , 1999, Plastic and reconstructive surgery.

[16]  K F Moos,et al.  A vision-based three-dimensional capture system for maxillofacial assessment and surgical planning. , 1998, British Journal of Oral and Maxillofacial Surgery.

[17]  A. Peterson,et al.  Technical note: Different techniques, different results--a comparison of photogrammetric and caliper-derived measurements. , 1998, American journal of physical anthropology.

[18]  E. Salter,et al.  Craniofacial Anthropometry: Practical Measurement of the Head and Face for Clinical, Surgical, and Research Use , 1997 .

[19]  F C van Ginkel,et al.  Quantification of facial morphology using stereophotogrammetry--demonstration of a new concept. , 1996, Journal of dentistry.

[20]  K. Bush,et al.  Three-dimensional facial anthropometry using a laser surface scanner: validation of the technique. , 1996, Plastic and reconstructive surgery.

[21]  M W Vannier,et al.  Anthropometric Optical Surface Imaging System Repeatability, Precision, and Validation , 1995, Annals of plastic surgery.

[22]  M Motoyoshi,et al.  A three-dimensional measuring system for the human face using three-directional photography. , 1992, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[23]  Ward Re,et al.  Measurement precision and reliability in craniofacial anthropometry: implications and suggestions for clinical applications. , 1991 .

[24]  J. Fleiss The design and analysis of clinical experiments , 1987 .

[25]  L. Farkas,et al.  Is photogrammetry of the face reliable? , 1980, Plastic and reconstructive surgery.

[26]  S. Washburn,et al.  Photography: an anthropometric tool. , 1952, American journal of physical anthropology.

[27]  J M TANNER,et al.  The reliability of the photogrammetric method of anthropometry, with a description of a miniature camera technique. , 1949, American journal of physical anthropology.

[28]  Mohammad Y Hajeer,et al.  Three-dimensional imaging in orthognathic surgery: the clinical application of a new method. , 2002, The International journal of adult orthodontics and orthognathic surgery.

[29]  S. C. Aung The role of laser surface imaging in the evaluation of craniomaxillofacial disorders: the Singapore General Hospital experience. , 1999, Annals of the Academy of Medicine, Singapore.

[30]  L. Farkas,et al.  Comparison of anthropometric and cephalometric measurements of the adult face. , 1999, The Journal of craniofacial surgery.

[31]  V F Ferrario,et al.  Facial three-dimensional morphometry. , 1996, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[32]  S. C. Aung,et al.  Evaluation of the laser scanner as a surface measuring tool and its accuracy compared with direct facial anthropometric measurements. , 1995, British journal of plastic surgery.

[33]  G M West,et al.  Reliability and repeatability of 3-D body scanner (LASS) measurements compared to anthropometry. , 1994, Annals of human biology.

[34]  Bruce Bradtmiller,et al.  Interobserver error in a large scale anthropometric survey , 1992, American journal of human biology : the official journal of the Human Biology Council.

[35]  R E Ward,et al.  Measurement precision and reliability in craniofacial anthropometry: implications and suggestions for clinical applications. , 1991, Journal of craniofacial genetics and developmental biology.