Charge-Collection and Single-Event Upset Measurements at the ISIS Neutron Source

Charge-collection measurements at the VESUVIO instrument at ISIS are described. Neutron SEU cross sections in SRAM-based FPGAs are measured. Results are compared to equivalent data from Los Alamos Neutron Science Center ICE House. The rate of single-event effects due to fast neutrons at VESUVIO is approximately 15% of that at LANSCE. In addition there is a strong thermal and epithermal component, sufficient to cause many events in devices containing small amounts of 10B. The effects of low-energy neutrons on a commercial CCD contaminated with traces of 10B are described. Cadmium shielding is found to be incompletely effective in separating the effects of fast and slow neutrons, and the implications for testing protocols and instrument design are discussed.

[1]  Eric G. Stevens,et al.  Front-illuminated full-frame charge-coupled-device image sensor achieves 85% peak quantum efficiency , 2002, IS&T/SPIE Electronic Imaging.

[2]  A. Lesea,et al.  The rosetta experiment: atmospheric soft error rate testing in differing technology FPGAs , 2005, IEEE Transactions on Device and Materials Reliability.

[3]  William C. McColgin,et al.  Bright-Pixel Defects in Irradiated CCD Image Sensors , 2007 .

[4]  S. Pontarelli,et al.  A New Hardware/Software Platform and a New 1/E Neutron Source for Soft Error Studies: Testing FPGAs at the ISIS Facility , 2007, IEEE Transactions on Nuclear Science.

[5]  S. Ansell,et al.  A design of an irradiation beamline for target station 2, ISIS , 2007, 2007 9th European Conference on Radiation and Its Effects on Components and Systems.

[6]  S. Platt,et al.  SEE-inducing effects of cosmic rays at the High-Altitude Research Station Jungfraujoch compared to accelerated test data , 2007, 2007 9th European Conference on Radiation and Its Effects on Components and Systems.

[7]  Z. Torok,et al.  Analysis of SEE-Inducing Charge Generation in the Neutron Beam at The Svedberg Laboratory , 2007, IEEE Transactions on Nuclear Science.

[8]  S. Platt,et al.  Application of Imaging Systems to Characterization of Single-Event Effects in High-Energy Neutron Environments , 2006, IEEE Transactions on Nuclear Science.

[9]  R. Gaillard,et al.  Investigation of Thermal Neutron Induced Soft Error Rates in Commercial Srams with 0.35 μm to 90 nm Technologies , 2006, 2006 IEEE International Reliability Physics Symposium Proceedings.

[10]  S. P. Platt,et al.  Development and application of a neutron sensor for single event effects analysis , 2005 .

[11]  E. Normand,et al.  Quantifying the Double-Sided Neutron SEU Threat, From Low Energy (Thermal) and High Energy ( ${>}10$ MeV) Neutrons , 2006, IEEE Transactions on Nuclear Science.