High-accuracy autocollimator calibration by interferometric 2D angle generator

Autocollimators are excellent measuring tools for many applications, such as adjustments or characterizations of precision mechanics, optics and instruments. Autocollimators have several characteristic error sources due to misalignment or nonideality of the collimator lens, the light source and the sensor. To fully characterize errors related to simultaneous engagement of both measurement axes of the autocollimator a two directional angle generator is necessary. In this paper, VTT MIKES interferometric 2-directional small angle generator (I2D-SAG) with updated model for calibration of autocollimators is described. It generates angles around 2 orthogonal axes with high accuracy. The maximum range of the I2D-SAG is ±1000” for both axes. In calibration of a high quality autocollimator a standard uncertainty below 0.01” can be reached. In addition, preliminary results of a comparison of I2D-SAG and PTB Spatial Angle Autocollimator Calibrator (SAAC) instrument are presented. This is the first comparison between 2D autocollimator calibration systems. In this comparison, a good agreement was reached in characterization of an electronic autocollimator over 900”×900” range.

[1]  Alistair B. Forbes,et al.  USE OF MONTE CARLO SIMULATION FOR UNCERTAINTY EVALUATION IN METROLOGY , 2001 .

[2]  Ralf D. Geckeler,et al.  Capabilities and limitations of the self-calibration of angle encoders , 2014 .

[3]  Andreas Just,et al.  Calibration of high-resolution electronic autocollimators against an angle comparator , 2003 .

[4]  B J Eves,et al.  The NRC autocollimator calibration facility , 2013 .

[5]  Ralf D. Geckeler,et al.  Modelling PTB's spatial angle autocollimator calibrator , 2013, Optical Metrology.

[6]  Jae Wan Kim,et al.  Calibration of angle artifacts and instruments using a high precision angle generator , 2013 .

[7]  Valeriy V. Yashchuk,et al.  Autocollimators for Deflectometry: Current Status and Future Progress , 2009 .

[8]  M. Krause,et al.  The new PTB angle comparator , 1998 .

[9]  Ralf D. Geckeler,et al.  Optimized use and calibration of autocollimators in deflectometry , 2007, SPIE Optical Engineering + Applications.

[10]  M. Cox The evaluation of key comparison data , 2002 .

[11]  R D Geckeler,et al.  Aperture alignment in autocollimator-based deflectometric profilometers. , 2016, The Review of scientific instruments.

[12]  Ralf D. Geckeler,et al.  Influence of the air’s refractive index on precision angle metrology with autocollimators , 2018 .

[13]  Wolfgang Osten,et al.  From plane to spatial angles: PTB’s spatial angle autocollimator calibrator , 2015 .

[14]  Harald Bosse,et al.  Comparison of angle standards with the aid of a high-resolution angle encoder , 2009 .

[15]  Ralf D. Geckeler,et al.  Distance-dependent influences on angle metrology with autocollimators in deflectometry , 2008, Optical Engineering + Applications.

[16]  Bernd Grubert Guidelines on the Calibration of Autocollimators , 2017 .

[17]  Ville Heikkinen,et al.  Interferometric 2D small angle generator for autocollimator calibration , 2017 .

[18]  Frank Siewert,et al.  The Nanometer Optical Component Measuring Machine , 2008 .

[19]  Ralf D. Geckeler,et al.  The spatial angle autocollimator calibrator: optimised model, uncertainty budget and experimental validation , 2018, Metrologia.

[20]  G. B. nsch,et al.  Measurement of the refractive index of air and comparison with modified Edl?n's formulae , 1998 .

[21]  Mourad Idir,et al.  Modern developments in X-ray and neutron optics , 2008 .

[22]  K Beissner,et al.  On a measure of consistency in comparison measurements , 2002 .

[23]  M Scheffer,et al.  Initial operation of a newly developed multichord motional Stark effect diagnostic in KSTAR. , 2016, The Review of scientific instruments.