T2 measurement in articular cartilage: Impact of the fitting method on accuracy and precision at low SNR
暂无分享,去创建一个
Olaf Dietrich | Maximilian F Reiser | Christian Glaser | Annie Horng | M. Reiser | O. Dietrich | J. Raya | C. Glaser | J. Weber | A. Horng | José G Raya | Jürgen Weber
[1] T. Mosher,et al. Cartilage MRI T2 relaxation time mapping: overview and applications. , 2004, Seminars in musculoskeletal radiology.
[2] A. Thomas,et al. Incidental magnetization transfer contrast in fast spin‐echo imaging of cartilage , 1996, Journal of magnetic resonance imaging : JMRI.
[3] Y. Xia,et al. Magic-Angle Effect in Magnetic Resonance Imaging of Articular Cartilage: A Review , 2000, Investigative radiology.
[4] D. Marquardt. An Algorithm for Least-Squares Estimation of Nonlinear Parameters , 1963 .
[5] Maximilian Reiser,et al. Three-dimensional analysis and visualization of regional MR signal intensity distribution of articular cartilage. , 2002, Medical engineering & physics.
[6] Jonathan A. Jones,et al. Optimal Sampling Strategies for the Measurement of Spin–Spin Relaxation Times , 1996 .
[7] J. Felmlee,et al. Bias of cartilage T2 values related to method of calculation. , 2008, Magnetic resonance imaging.
[8] V J Schmithorst,et al. MR imaging and T2 mapping of femoral cartilage: in vivo determination of the magic angle effect. , 2001, AJR. American journal of roentgenology.
[9] C. Scott. Bessel Functions of Integer Order , 1998 .
[10] H. Gudbjartsson,et al. The rician distribution of noisy mri data , 1995, Magnetic resonance in medicine.
[11] S Majumdar,et al. Quantitative magnetic resonance imaging of articular cartilage in osteoarthritis. , 2007, European cells & materials.
[12] R. Henkelman. Measurement of signal intensities in the presence of noise in MR images. , 1985, Medical physics.
[13] Van,et al. Spatial variation of T2 in human articular cartilage. , 1997, Radiology.
[14] G. Weiss,et al. Optimal time spacings for T2 measurements: monoexponential and biexponential systems , 1998, NMR in biomedicine.
[15] Wilhelm Horger,et al. Quantitative T2 Mapping of Matrix-Associated Autologous Chondrocyte Transplantation at 3 Tesla: An In Vivo Cross-Sectional Study , 2007, Investigative radiology.
[16] Cheng Guan Koay,et al. Analytically exact correction scheme for signal extraction from noisy magnitude MR signals. , 2006, Journal of magnetic resonance.
[17] Aaron J. Miller,et al. The use of power images to perform quantitative analysis on low SNR MR images. , 1993, Magnetic resonance imaging.
[18] V. Mlynárik,et al. Transverse relaxation mechanisms in articular cartilage. , 2004, Journal of magnetic resonance.
[19] P. Basser,et al. The b matrix in diffusion tensor echo‐planar imaging , 1997, Magnetic resonance in medicine.
[20] M. Reiser,et al. Voxel-based reproducibility of T2 relaxation time in patellar cartilage at 1.5 T with a new validated 3D rigid registration algorithm , 2009, Magnetic Resonance Materials in Physics, Biology and Medicine.
[21] J. Boire,et al. T2 maximum likelihood estimation from multiple spin‐echo magnitude images , 1996, Magnetic resonance in medicine.
[22] H. Carr,et al. The Principles of Nuclear Magnetism , 1961 .
[23] Maximilian Reiser,et al. T2 Quantitation of Human Articular Cartilage in a Clinical Setting at 1.5 T: Implementation and Testing of Four Multiecho Pulse Sequence Designs for Validity , 2004, Investigative radiology.
[24] J. Holden,et al. The propagation of stochastic pixel noise into magnitude and phase values in the Fourier analysis of digital images. , 1986, Physics in medicine and biology.
[25] J R MacFall,et al. An analysis of noise propagation in computed T2, pseudodensity, and synthetic spin-echo images. , 1986, Medical physics.
[26] Gil Navon,et al. Multinuclear NMR and microscopic MRI studies of the articular cartilage nanostructure , 2006, NMR in biomedicine.
[27] Peter A Hardy,et al. Calculating T2 in images from a phased array receiver , 2009, Magnetic resonance in medicine.
[28] Charles L. Lawson,et al. 23. Linear Least Squares with Linear Inequality Constraints , 1995 .
[29] Charles L. Lawson,et al. Solving least squares problems , 1976, Classics in applied mathematics.
[30] E. McVeigh,et al. Signal-to-noise measurements in magnitude images from NMR phased arrays , 1997, Proceedings of the 19th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 'Magnificent Milestones and Emerging Opportunities in Medical Engineering' (Cat. No.97CH36136).
[31] M. Reiser,et al. Global and regional reproducibility of T2 relaxation time measurements in human patellar cartilage , 2006, Magnetic resonance in medicine.
[32] M. Bastin,et al. A theoretical study of the effect of experimental noise on the measurement of anisotropy in diffusion imaging. , 1998, Magnetic resonance imaging.
[33] M. Bronskill,et al. Criteria for analysis of multicomponent tissue T2 relaxation data , 1996, Magnetic resonance in medicine.
[34] A. MacKay,et al. Are mono‐exponential fits to a few echoes sufficient to determine T2 relaxation for in vivo human brain? , 1999, Magnetic resonance in medicine.
[35] S. Schoenberg,et al. Influence of multichannel combination, parallel imaging and other reconstruction techniques on MRI noise characteristics. , 2008, Magnetic resonance imaging.
[36] V J Schmithorst,et al. Spatial variation in cartilage T2 of the knee , 2001, Journal of magnetic resonance imaging : JMRI.
[37] S. Heiland,et al. Noise correction for the exact determination of apparent diffusion coefficients at low SNR , 2001, Magnetic resonance in medicine.
[38] Kenneth Levenberg. A METHOD FOR THE SOLUTION OF CERTAIN NON – LINEAR PROBLEMS IN LEAST SQUARES , 1944 .
[39] S. Rice. Mathematical analysis of random noise , 1944 .