Stereotactic IMRT for prostate cancer: Setup accuracy of a new stereotactic body localization system

The purpose of this work is to prospectively assess the setup accuracy that can be achieved with a stereotactic body localizer (SBL) in immobilizing patients for stereotactic intensity‐modulated radiotherapy (IMRT) for prostate cancer. By quantifying this important factor and target mobility in the SBL, we expect to provide a guideline for selecting planning target volume margins for stereotactic treatment planning. We analyzed data from 40 computed tomography (CT) studies (with slice thickness of 3 mm) involving 10 patients with prostate cancer. Each patient had four sets of CT scans during the course of radiotherapy. For the purpose of this study, all four sets of CT scans were obtained with the patients immobilized in a customized body pillow formed by vacuum suction. Unlike other immobilization devices, this system consists not only of a customized body pillow, but also of a fixation sheet used to suppress patient respiratory motion, a stereotactic body frame to provide stereotaxy, and a carbon fiber base board to which both the body cushion and the frame are affixed. We identified four bony landmarks and measured their coordinates in the stereotactic body frame on each set of CT scans. The displacements of the bony landmarks from their corresponding positions on the simulation scan (first CT scan) were analyzed in three dimensions in terms of overall, systematic, and random categories. The initial planned isocenter was also marked on the patients' skin with fiducials for each CT study. The distance from each bony landmark to the fiducial‐based isocenter was measured and compared among the four sets of CT scans. The deviations in distances were also compared to those measured from the landmarks to the stereotactic frame center, in order to determine the effectiveness of the rigid body frame in positioning patients with prostate cancer. Target inter‐fraction motion in this system was also studied for five patients by measuring the deviations in distances from the target geometric center to the bony landmarks. Our results showed that the overall setup accuracy had standard deviations (SDs) of 2.58 mm, 2.41 mm, and 3.51 mm in lateral (LAT), anterior‐posterior (AP), and superior‐inferior (SI) directions, respectively. The random component had SDs of 1.72 mm, 2.06 mm, and 2.79 mm, and the systematic component showed SDs of 0.92 mm, –0.27 mm, and 0.90 mm in these three directions. In terms of three‐dimensional vector, the mean displacement over 116 measurements was 3.0 mm with an SD of 1.29 mm. Compared to the rigid reference, the skin‐mark‐based reference was less reliable for patient repositioning in terms of reproducing known bony landmark positions. The mean target mobility relative to the bony landmarks was 2.22±3.45 mm,0.17±1.11 mm, and 0.11±2.69 mm in the AP, LAT, and SI directions, respectively. In conclusion, the body immobilization system has the ability to immobilize prostate cancer patients with satisfactory setup accuracy for fractionated extracranial stereotactic radiotherapy. A rigid frame system serves as a reliable alignment reference in terms of repositioning patients into the planning position, while skin‐based reference showed larger deviations in repositioning patients. PACS number: 87.53Ly

[1]  C. Perez,et al.  Impact of tumor control on survival in carcinoma of the lung treated with irradiation. , 1986, International journal of radiation oncology, biology, physics.

[2]  K. Bratengeier,et al.  Three dimensional variability in patient positioning using bite block immobilization in 3D-conformal radiation treatment for ENT-tumors. , 1997, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[3]  A Jackson,et al.  Partial irradiation of the rectum. , 2001, Seminars in radiation oncology.

[4]  Lei Dong,et al.  Use of portal images and BAT ultrasonography to measure setup error and organ motion for prostate IMRT: implications for treatment margins. , 2003, International journal of radiation oncology, biology, physics.

[5]  F Lohr,et al.  Extracranial stereotactic radiation therapy: set-up accuracy of patients treated for liver metastases. , 2000, International journal of radiation oncology, biology, physics.

[6]  Radhe Mohan,et al.  Near simultaneous computed tomography image-guided stereotactic spinal radiotherapy: an emerging paradigm for achieving true stereotaxy. , 2003, International journal of radiation oncology, biology, physics.

[7]  T Haycocks,et al.  Positioning errors and prostate motion during conformal prostate radiotherapy using on-line isocentre set-up verification and implanted prostate markers. , 2001, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[8]  F. Lohr,et al.  Radiosurgery alone or in combination with whole-brain radiotherapy for brain metastases. , 1998, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.

[9]  C. Ling,et al.  Dose escalation with three-dimensional conformal radiation therapy affects the outcome in prostate cancer. , 1999, International journal of radiation oncology, biology, physics.

[10]  T E Schultheiss,et al.  Lateral rectal shielding reduces late rectal morbidity following high dose three-dimensional conformal radiation therapy for clinically localized prostate cancer: further evidence for a significant dose effect. , 1996, International journal of radiation oncology, biology, physics.

[11]  Jan J W Lagendijk,et al.  Comparison of megavoltage position verification for prostate irradiation based on bony anatomy and implanted fiducials. , 2003, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[12]  F. Lohr,et al.  Noninvasive patient fixation for extracranial stereotactic radiotherapy. , 1999, International journal of radiation oncology, biology, physics.

[13]  L. Verhey,et al.  Immobilizing and Positioning Patients for Radiotherapy. , 1995, Seminars in radiation oncology.

[14]  P. Levendag,et al.  Field margin reduction using intensity-modulated x-ray beams formed with a multileaf collimator. , 1997, International journal of radiation oncology, biology, physics.

[15]  Lei Dong,et al.  Intrafraction prostate motion during IMRT for prostate cancer. , 2001, International journal of radiation oncology, biology, physics.

[16]  T Mizowaki,et al.  The effectiveness of an immobilization device in conformal radiotherapy for lung tumor: reduction of respiratory tumor movement and evaluation of the daily setup accuracy. , 2001, International journal of radiation oncology, biology, physics.

[17]  L. Schad,et al.  [Image-oriented planning of minimally invasive conformal irradiation of the head-neck area]. , 1996, Der Radiologe.

[18]  I. Lax,et al.  Stereotactic radiotherapy of malignancies in the abdomen. Methodological aspects. , 1994, Acta oncologica.

[19]  U Oppitz,et al.  Stereotactic radiotherapy of extracranial targets: CT-simulation and accuracy of treatment in the stereotactic body frame. , 2000, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[20]  S. Smalley The effect of dose on local control of prostate cancer. , 1989, International journal of radiation oncology, biology, physics.

[21]  George Starkschall,et al.  Prostate cancer radiation dose response: results of the M. D. Anderson phase III randomized trial. , 2002, International journal of radiation oncology, biology, physics.