Improved efficiency of high resolution thermal and cold neutron imaging

Abstract Spatial resolution and detection efficiency of neutron imaging detectors are the crucial parameters defining the ultimate resolution in neutron radiography, micro-tomography and other non-destructive testing techniques. The most widely used neutron imaging systems use a neutron-sensitive scintillation screen lens coupled to a CCD or a CMOS sensor. The highest spatial resolution in those devices is achieved using very thin scintillation screens which reduce image blurring due to light spreading in the scintillator. Thus high spatial resolution and high detection efficiency usually could not be achieved in the same device. Neutron counting detectors using neutron-sensitive microchannel plates (MCPs) overcome that deficiency by providing a long neutron absorption path (∼mm scale) and preserving events within a single sub-10 μm pore. At the same time, each neutron in those detectors can be time-tagged with ∼1 μs accuracy. The latest 10 B and gadolinium-doped MCPs developed by Nova Scientific were tested at the cold neutron facility ICON of Paul Scherrer Institute and proved to be capable of imaging cold neutrons with 70% detection efficiency. Neutron radiography and micro-tomography confirmed the high spatial resolution capabilities of the latest generation of high efficiency microchannel plates. The high spatial and temporal resolution of our neutron counting detectors allows for high resolution micro-tomography, novel studies of material composition, texture, phase and strain through Bragg edge imaging as well as dynamic studies of magnetic fields inside of thick samples, exploiting the neutron spin interactions with magnetic fields.

[1]  Rafael Ballabriga,et al.  Timepix, a 65k programmable pixel readout chip for arrival time, energy and/or photon counting measurements , 2007 .

[2]  Daniel S. Hussey,et al.  New neutron imaging facility at the NIST , 2005 .

[3]  Burkhard Schillinger,et al.  Construction and assembly of the neutron radiography and tomography facility ANTARES at FRM II , 2005 .

[4]  Bragg-edge Imaging with Neutrons , 2008 .

[5]  A. Steuwer,et al.  The energy-selective option in neutron imaging , 2009 .

[6]  W. B. Feller,et al.  High-resolution neutron radiography with microchannel plates: Proof-of-principle experiments at PSI , 2009 .

[7]  R. G. Downing,et al.  Efficiency optimization of microchannel plate (MCP) neutron imaging detectors. I. Square channels with 10B doping , 2005 .

[8]  Jason McPhate,et al.  Detection efficiency, spatial and timing resolution of thermal and cold neutron counting MCP detectors , 2009 .

[9]  Pierre Boillat,et al.  The micro-setup for neutron imaging: A major step forward to improve the spatial resolution , 2007 .

[10]  J. McPhate,et al.  Energy-Resolving Neutron Transmission Radiography at the ISIS Pulsed Spallation Source With a High-Resolution Neutron Counting Detector , 2008, IEEE Transactions on Nuclear Science.

[11]  Josef Uher,et al.  Data acquisition and processing software package for Medipix2 , 2006 .

[12]  Eberhard Lehmann,et al.  Energy-selective neutron transmission imaging at a pulsed source , 2007 .

[13]  J. Banhart,et al.  The new cold neutron radiography and tomography instrument CONRAD at HMI Berlin , 2006 .

[14]  David San Segundo Bello,et al.  An interface board for the control and data acquisition of the Medipix2 chip , 2003 .