Evaluation of Electrorheological Fluid Dampers for Applications at 3-T MRI Environment

This paper evaluates the use of electrorheological fluids (ERFs) within a magnetic resonance imaging (MRI) environment. ERF is a semiactive variable impedance material, which could be used as an alternative type of resistive force/torque generation or in combination with other actuators as a damper/clutch to modulate the output force/torque of the actuator. In this paper, an ERF damper/brake is introduced and its magnetic resonance (MR) compatibility is examined at a 3-T MR imaging environment by measuring the output performance of the damper and the SNR of the MRI images. The experimental results showed that damper's resistive force generation while positioned within the MRI is almost the same as that in normal operation. The signal-to-noise investigation was performed both with a phantom and human. The results indicated that the ERF damper did not affect the MRI images when it was operated over 30 cm away from the MRI's RF coil. We hope that the synthesis and tables presented in this paper can facilitate the choice of ERF brake actuation principle to various applications in an MR environment.

[1]  W. Gedroyc Interventional magnetic resonance imaging. , 1997, BJU international.

[2]  S. Koskinen [Interventional magnetic resonance imaging]. , 1999, Duodecim; laaketieteellinen aikakauskirja.

[3]  C. Mavroidis,et al.  MR_CHIROD v.2: Magnetic Resonance Compatible Smart Hand Rehabilitation Device for Brain Imaging , 2008, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[4]  H. Gudbjartsson,et al.  The rician distribution of noisy mri data , 1995, Magnetic resonance in medicine.

[5]  F. Jolesz,et al.  Genesis of interventional MRI , 1998, Journal of Magnetic Resonance Imaging.

[6]  J. L. Sproston,et al.  Applications of electro-rheological fluids in vibration control: a survey , 1996 .

[7]  R. Blanco,et al.  Interventional and intraoperative MRI at low field scanner--a review. , 2005, European journal of radiology.

[8]  Christina Triantafyllou,et al.  fMRI-compatible rehabilitation hand device , 2006, Journal of NeuroEngineering and Rehabilitation.

[9]  F. Jolesz Invited. Interventional and intraoperative MRI: A general overview of the field , 1998, Journal of magnetic resonance imaging : JMRI.

[10]  Roger P. Woods,et al.  Ankle dorsiflexion as an fMRI paradigm to assay motor control for walking during rehabilitation , 2004, NeuroImage.

[11]  Constantinos Mavroidis,et al.  Magnetic resonance-compatible robotic and mechatronics systems for image-guided interventions and rehabilitation: a review study. , 2007, Annual review of biomedical engineering.

[12]  Akio Yamamoto,et al.  Actuation Methods for Applications in MR Environments , 2006 .

[13]  B. Rosen,et al.  A functional MRI study of subjects recovered from hemiparetic stroke. , 1997, Stroke.

[14]  R M Harrison,et al.  A comparison of two methods for measuring the signal to noise ratio on MR images , 1999, Physics in medicine and biology.