The Penn State Safety Floor: Part I--Design parameters associated with walking deflections.

A new flooring system has been developed to reduce peak impact forces to the hips when humans fall. The new safety floor is designed to remain relatively rigid under normal walking conditions, but to deform elastically when impacted during a fall. Design objectives included minimizing peak force experienced by the femur during a fall-induced impact, while maintaining a maximum of 2 mm of floor deflection during walking. Finite Element Models (FEMs) were developed to capture the complex dynamics of impact response between two deformable bodies. Validation of the finite element models included analytical calculations of theoretical buckling column response, experimental quasi-static loading of full-scale flooring prototypes, and flooring response during walking trials. Finite Element Method results compared well with theoretical and experimental data. Both finite element and experimental data suggest that the proposed safety floor can effectively meet the design goal of 2 mm maximum deflection during walking, while effectively reducing impact forces during a fall.

[1]  Tanchum Weller,et al.  Experimental and theoretical studies of columns under axial impact , 1982 .

[2]  P. Freakley,et al.  Theory and practice of engineering with rubber , 1978 .

[3]  P. Meunier Prevention of hip fractures. , 1993, The American journal of medicine.

[4]  J A Ward,et al.  Balance, reaction time, and muscle strength in exercising and nonexercising older women: a pilot study. , 1993, Archives of physical medicine and rehabilitation.

[5]  R. Heidel,et al.  Healthy People 2000: national health promotion and disease prevention objectives (excerpts). US Public Health Service. , 1991, Journal of allied health.

[6]  B Krølner,et al.  Vertebral bone loss: an unheeded side effect of therapeutic bed rest. , 1983, Clinical science.

[7]  S. Lord,et al.  Visual acuity and contrast sensitivity in relation to falls in an elderly population. , 1991, Age and ageing.

[8]  Exercise and Other Factors in the Prevention of Hip Fracture: The Leisure World Study , 1991, Epidemiology.

[9]  M. M. Petersen,et al.  Effect of external hip protectors on hip fractures , 1993, The Lancet.

[10]  W C Hayes,et al.  Energy-shunting hip padding system attenuates femoral impact force in a simulated fall. , 1995, Journal of biomechanical engineering.

[11]  R. Sattin,et al.  Fall Injuries Among the Elderly , 1988, Journal of the American Geriatrics Society.

[12]  S. Lord,et al.  Physiological Factors Associated with Falls in Older Community‐Dwelling Women , 1994, Journal of the American Geriatrics Society.

[13]  D.P. Colvin,et al.  A Fall Intervention/mobility Aid System For Elderly And Rehabilitative Populations , 1991, Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society Volume 13: 1991.

[14]  Philippa Williams,et al.  The Effect of a 12‐Month Exercise Trial on Balance, Strength, and Falls in Older Women: A Randomized Controlled Trial , 1995, Journal of the American Geriatrics Society.

[15]  D A Streit,et al.  The Penn State Safety Floor: Part II--Reduction of fall-related peak impact forces on the femur. , 1998, Journal of biomechanical engineering.

[16]  W C Hayes,et al.  Fall severity and bone mineral density as risk factors for hip fracture in ambulatory elderly. , 1994, JAMA.

[17]  V. Askegaard,et al.  Protection against hip fractures by energy absorption. , 1992, Danish medical bulletin.

[18]  J G Rodriguez,et al.  The incidence of fall injury events among the elderly in a defined population. , 1990, American journal of epidemiology.

[19]  P. Gogia,et al.  Bed rest effect on extremity muscle torque in healthy men. , 1988, Archives of physical medicine and rehabilitation.

[20]  M. Tinetti,et al.  Fall risk index for elderly patients based on number of chronic disabilities. , 1986, The American journal of medicine.

[21]  R. Sattin Falls among older persons: a public health perspective. , 1992, Annual review of public health.

[22]  Karla Damus,et al.  Risk Factors Associated with Immobility , 1988, Journal of the American Geriatrics Society.

[23]  R. Wallace,et al.  Iowa FICSIT Trial: The Feasibility of Elderly Wearing a Hip Joint Protective Garment to Reduce Hip Fractures , 1993, Journal of the American Geriatrics Society.

[24]  A Heinonen,et al.  Epidemiology of hip fractures. , 1996, Bone.

[25]  J M Vogel,et al.  Effect of prolonged bed rest on bone mineral. , 1970, Metabolism: clinical and experimental.

[26]  G. Sorock Falls among the elderly: epidemiology and prevention. , 1988, American journal of preventive medicine.

[27]  S. Lord,et al.  Physiological factors associated with injurious falls in older people living in the community. , 1992, Gerontology.

[28]  J. Grisso,et al.  Injuries in an Elderly Inner‐City Population , 1990, Journal of the American Geriatrics Society.

[29]  R. P. Fabio,et al.  Influence of sensory inputs on standing balance in community-dwelling elders with a recent history of falling. , 1992, Physical therapy.

[30]  M. Tinetti,et al.  A multifactorial intervention to reduce the risk of falling among elderly people living in the community. , 1994, The New England journal of medicine.

[31]  J. A. Waller Falls among the elderly—Human and environmental factors☆ , 1978 .