A simple, calibrated, ultra-low frequency ballistocardiograph

The physical basis of ballistocardiography has now been thoroughly investigated and there is general agreement that the ultra-low frequency system is the most satisfactory. The physiological basis of ballistocardiography and its clinical application require further study. For this purpose a reliable instrument which can be easily operated and calibrated is needed.The design of such an instrument and its calibrating system, with an analysis of its performance and an indication of the results obtained by its use is presented.SommaireLes bases physique de la ballistocardiographie ont été maintenant étudiées à fond et de l'avis général le système T.B.F. est le plus satisfaisant. Par contre les bases physiologiques de la ballistocardiographie et son application clinique nécessitent des études supplémentaires. Dans ce but il est indispensable de posséder un appareillage sûr qui puisse être utilisé et étalonné avec facilité. On présente la réalisation d'un tel instrument ainsi que son système d'étalonnage en même temps qu'une analyse de ses performances et une indication des résultats obtenus.ZusammenfassungDie physikalische Basis der Ballistokardiographie ist jetzt vollständig erforscht und die allgemeine Übereinstimmung geht dahin, daß das Ultrakurzfrequenz-System das geeignetste ist. Die physiologische Basis der Ballistokardiographie und ihre klinische Anwendung erfordert weitere Untersuchungen. Für diesen Zweck ist ein zuverlässiges Gerät nötig, das leicht bedient und geeicht werden kann. Der Entwurf eines solchen Instrumentes und dessen Eichungssystems, eine Analyse seiner Leistung und die bei seiner Anwendung erzeilten Ergebnisse wird mitgeteilt.

[1]  W. V. Wittern Ballistocardiography with elimination of the influence of the vibration properties of the body , 1953 .

[2]  H. C. Burger,et al.  Physical basis of ballistocardiography. III. , 1956, American heart journal.

[3]  Howard J. Curtis,et al.  THE DESIGN OF THE BALLISTOCARDIOGRAPH , 1944 .

[4]  S. A. Talbot,et al.  Dynamic Comparison of Current Ballistocardiographic Methods: Part I Artefacts in the Dynamically Simple Ballistocardiographic Methods , 1955, Circulation.

[5]  T. A. Perls,et al.  An Integrating and Differentiating Bar‐Magnet Velocity Meter for Use in Ballistocardiography , 1954 .

[6]  I. Starr,et al.  STUDIES ON THE ESTIMATION OF CARDIAC OUPTUT IN MAN, AND OF ABNORMALITIES IN CARDIAC FUNCTION, FROM THE HEART'S RECOIL AND THE BLOOD'S IMPACTS; THE BALLISTOCARDIOGRAM , 1939 .

[7]  H. C. Burger,et al.  Physical basis of the low-frequency ballistocardiograph. , 1953, American heart journal.

[8]  S. A. Talbot,et al.  Dynamic Comparison of Current Ballistocardiographic Methods: Part III. Derivation of Cardiovascular Force from Body Motions , 1955, Circulation.

[9]  W C HIXSON,et al.  BIOTELEMETRY OF THE TRIAXIAL BALLISTOCARDIOGRAM AND ELECTROCARDIOGRAM IN A WEIGHTLESS ENVIRONMENT. MONOGR NO. 10. , 1964, Research report. Naval School of Aviation Medicine.

[10]  H. C. Burger,et al.  Physical basis of ballistocardiography. IV. The relative movement of subject and ballistocardiograph. , 1956, American heart journal.

[11]  H. C. Burger,et al.  Physical basis of ballistocardiography. V. The distortion of the ballistocardiogram caused by the movement of the heart inside the body. , 1957, American heart journal.

[12]  H. C. Burger,et al.  A theoretical elucidation of the notion ventricular gradient. , 1957, American heart journal.

[13]  H. C. Burger,et al.  Physical basis of ballistocardiography. II. The quantities that can be measured with different types of ballistocardiographs and their mutual relations. , 1956, American heart journal.