Fluoroscopic navigation system for hip surface replacement

Metal-on-metal hip resurfacing arthroplasties represent an alternative to total hip arthroplasties for young and active patients, enabling the preservation of intact femoral bone and therefore improving the prognosis for future hip joint replacements. Follow-up studies have shown that the main reasons for early implant failure are mal-orientation of the implant stem in relation to the femoral neck axis, and notching of the femoral neck during femoral head preparation, as well as by exposed cancellous bone after implantation. A computer-assisted planning and navigation system for the implantation of femoral hip resurfacing implants has been developed which supports the surgeon during intraoperative fluoroscopy-based planning and navigation of implant positioning. This paper presents the results of a cadaver study performed to evaluate the system's functionality and accuracy.

[1]  Robert Middleton,et al.  HIP RESURFACING WITH COMPUTER NAVIGATION: INITIAL EXPERIENCE AT THE ROYAL BOURNEMOUTH HOSPITAL, UK , 2006 .

[2]  D. Back,et al.  Femoral neck fractures following Birmingham hip resurfacing: a national review of 50 cases. , 2005, The Journal of bone and joint surgery. British volume.

[3]  P. Pynsent,et al.  Metal on Metal Surface Replacement of the Hip: Experience of the McMinn Prosthesis , 1996, Clinical orthopaedics and related research.

[4]  T. Hess,et al.  Einsatz der Navigation beim Oberflächenersatz des Hüftgelenks , 2004, Der Orthopäde.

[5]  H. Amstutz,et al.  Orientation of the femoral component in surface arthroplasty of the hip. , 2004, The Journal of bone and joint surgery. American volume.

[6]  P. Campbell,et al.  Metal-on-metal hybrid surface arthroplasty: two to six-year follow-up study. , 2004, The Journal of bone and joint surgery. American volume.

[7]  P. Beaulé,et al.  Surface arthroplasty for osteonecrosis of the hip: hemiresurfacing versus metal-on-metal hybrid resurfacing. , 2004, The Journal of arthroplasty.

[8]  P B Pynsent,et al.  Metal-on-metal resurfacing of the hip in patients under the age of 55 years with osteoarthritis. , 2004, The Journal of bone and joint surgery. British volume.

[9]  T. Gampe,et al.  [Intraoperative navigation for hip resurfacing. Methods and first results]. , 2004, Der Orthopade.

[10]  H. Amstutz,et al.  Orientation of the femoral component in surface arthroplasty of the hip. A biomechanical and clinical analysis. , 2004, The Journal of bone and joint surgery. American volume.

[11]  P B Pynsent,et al.  Birmingham hip resurfacing arthroplasty. A minimum follow-up of five years. , 2005, The Journal of bone and joint surgery. British volume.

[12]  K. Radermacher,et al.  Evaluation of deformable models for femoral neck surgery , 2004, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[13]  H. Amstutz,et al.  Fracture of the neck of the femur after surface arthroplasty of the hip. , 2004, The Journal of bone and joint surgery. American volume.

[14]  Z Jianguo,et al.  Computer-assisted femoral head resurfacing , 2009, Journal of medical engineering & technology.