In Situ Characterization of Two Wireless Transmission Schemes for Ingestible Capsules

We report the experimental in situ characterization of 30-40 MHz and 868 MHz wireless transmission schemes for ingestible capsules, in porcine carcasses. This includes a detailed study of the performance of a magnetically coupled near-field very high-frequency (VHF) transmission scheme that requires only one eighth of the volume and one quarter of the power consumption of existing 868-MHz solutions. Our in situ measurements tested the performance of four different capsules specially constructed for this study (two variants of each transmission scheme), in two scenarios. One mimicked the performance of a body-worn receiving coil, while the other allowed the characterization of the direction-dependent signal attenuation due to losses in the surrounding tissue. We found that the magnetically coupled near-field VHF telemetry scheme presents an attractive option for future, miniturized ingestible capsules for medical applications.

[1]  Mackay Rs,et al.  Radio Telemetering from within the Body: Inside information is revealed by tiny transmitters that can be swallowed or implanted in man or animal. , 1961 .

[2]  J. Pandolfino,et al.  Ambulatory Esophageal pH Monitoring Using a Wireless System , 2003, American Journal of Gastroenterology.

[3]  H. Adel,et al.  Antennas for a body area network , 2003, IEEE Antennas and Propagation Society International Symposium. Digest. Held in conjunction with: USNC/CNC/URSI North American Radio Sci. Meeting (Cat. No.03CH37450).

[4]  William G. Scanlon,et al.  Analysis of the performance of IEEE 802.15.4 for medical sensor body area networking , 2004, 2004 First Annual IEEE Communications Society Conference on Sensor and Ad Hoc Communications and Networks, 2004. IEEE SECON 2004..

[5]  P. Swain,et al.  Wireless capsule endoscopy. , 2002, The Israel Medical Association journal : IMAJ.

[6]  G. Iddan,et al.  Wireless capsule endoscopy , 2003, Gut.

[7]  Alan F. Murray,et al.  Data transmission for implantable microsystems using magnetic coupling , 2005 .

[8]  Geert Van der Plas,et al.  Ultra-wide-band transmitter for low-power wireless body area networks: design and evaluation , 2005, IEEE Transactions on Circuits and Systems I: Regular Papers.

[9]  R. Stuart Mackay,et al.  Radio Telemetering from within the Body , 1961, Science.

[10]  Klaus Finkenzeller,et al.  Book Reviews: RFID Handbook: Fundamentals and Applications in Contactless Smart Cards and Identification, 2nd ed. , 2004, ACM Queue.

[11]  Akram Alomainy,et al.  UWB on-body radio propagation and system modelling for wireless body-centric networks , 2006 .

[12]  Lei Wang,et al.  Networked wireless microsystem for remote gastrointestinal monitoring , 2003, TRANSDUCERS '03. 12th International Conference on Solid-State Sensors, Actuators and Microsystems. Digest of Technical Papers (Cat. No.03TH8664).

[13]  A ‘Radio Pill’ , 1957, Nature.

[14]  Lei Wang,et al.  A programmable microsystem using system-on-chip for real-time biotelemetry , 2005, IEEE Transactions on Biomedical Engineering.

[15]  Noeller Hg,et al.  The endoradio sound for electrical pH measurement in the stomach and its clinical significance , 1960 .

[16]  Lawrence C. Chirwa,et al.  Electromagnetic radiation from ingested sources in the human intestine between 150 MHz and 1.2 GHz , 2003, IEEE Transactions on Biomedical Engineering.

[17]  Lei Wang,et al.  Biocompatibility of a Lab-on-a-Pill Sensor in Artificial Gastrointestinal Environments , 2006, IEEE Transactions on Biomedical Engineering.

[18]  Klaas Kramer,et al.  Evaluation and applications of radiotelemetry in small laboratory animals. , 2003, Physiological genomics.

[19]  Geert Van der Plas,et al.  Ultra-WideBand Transmitter for Wireless Body Area Networks , 2005 .

[20]  Luca Benini,et al.  Design and implementation of WiMoCA node for a body area wireless sensor network , 2005, 2005 Systems Communications (ICW'05, ICHSN'05, ICMCS'05, SENET'05).

[21]  R. W. Lau,et al.  The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues. , 1996, Physics in medicine and biology.

[22]  William G. Scanlon,et al.  Radiowave propagation from a tissue-implanted source at 418 MHz and 916.5 MHz , 2000, IEEE Transactions on Biomedical Engineering.