Stress influence on orthodontic system components under simulated treatment loadings

BACKGROUND AND OBJECTIVE Mini-implants have been developed and effectively used by clinicians as anchorage for orthodontic tooth movement. The objective of this study was to elucidate the stress response of orthodontic forces on the periodontal system, bone tissues, mini-implant and the bracket-enamel interface. METHODS Computer tomography images of a commercially available mini-implant, an orthodontic bracket bonded to a central incisor, and jawbone section models were used to reconstruct three dimensional computer models. These models were exported and meshed in an ABAQUSⓇ finite-element package. Material properties, multi-segment interactions, boundary and loading conditions were then applied to each component. Finite-element analyses were conducted to elucidate the effect of orthodontic force on the equivalent von Mises stress response within the simulated orthodontic system. RESULTS The highest stress values in the orthodontic system were predicted at the mini-implant neck, at the interface of the cortical bone, and gradually decreased in the internal apical direction of the miniscrew. On the alveolar bone, the maximum stress values were located in the alveolar cortical bone near the cervical areas of the mini-implant, which is in line with clinical findings of area where bone loss was found post orthodontic tooth treatment. Another peak of von Mises stress response was found in the enamel bracket junction with a maximum up to 186.05 MPa. To ensure good bonding between the enamel and bracket, it is vital to select carefully the type and amount of bonding materials used in the bracket-enamel interface to assure an appropriate load distribution between the teeth and alveolar bone. The results also revealed the significance of the periodontal ligaments, acting as an intermediate cushion element, in the load transfer mechanism. CONCLUSIONS This study is sought to identify the stress response in a simulated orthodontic system to minimize the failure rate of mini-implants and bracket loss during orthodontic treatment.

[1]  Safiya Sana,et al.  Mini- Implant Materials: An Overview , 2013 .

[2]  Mutlu Ozcan,et al.  A strain gauge analysis of microstrain induced by various splinting methods and acrylic resin types for implant impressions. , 2012, The International journal of oral & maxillofacial implants.

[3]  Luiz Gonzaga Gandini,et al.  Scientific use of the finite element method in Orthodontics , 2015, Dental press journal of orthodontics.

[4]  J. Lee,et al.  Comparison of mechanical property and role between enamel and dentin in the human teeth , 2014, Journal of dental biomechanics.

[5]  B. Melsen,et al.  The Finite Element Method: a Tool to Study Orthodontic Tooth Movement , 2005, Journal of dental research.

[6]  Peter Ngan,et al.  Three-dimensional modeling and finite element analysis in treatment planning for orthodontic tooth movement. , 2011, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[7]  T. Eliades,et al.  Comparative analysis of numerical and experimental data of orthodontic mini-implants. , 2011, European journal of orthodontics.

[8]  A Asundi,et al.  A strain gauge and photoelastic analysis of in vivo strain and in vitro stress distribution in human dental supporting structures. , 2000, Archives of oral biology.

[9]  J. Ríos-Santos,et al.  Influence of the Elastic Modulus on the Osseointegration of Dental Implants , 2019, Materials.

[10]  P O'Higgins,et al.  The effects of the periodontal ligament on mandibular stiffness: a study combining finite element analysis and geometric morphometrics. , 2011, Journal of biomechanics.

[11]  G. Liu,et al.  Application of finite element analysis in implant dentistry: a review of the literature. , 2001, The Journal of prosthetic dentistry.

[12]  Ugo Andreaus,et al.  Coupling image processing and stress analysis for damage identification in a human premolar tooth , 2011, Comput. Methods Programs Biomed..

[13]  D. Bodnar,et al.  FEM analysis of masticatory induced stresses over surrounding tissues of dental implant , 2019, Romanian Biotechnological Letters.

[14]  L. C. Brandão,et al.  Finishing procedures in orthodontics: dental dimensions and proportions (microesthetics). , 2013, Dental press journal of orthodontics.

[15]  M. Pasque,et al.  Severe aortic insufficiency and normal systolic function: determining regional left ventricular wall stress by finite-element analysis. , 2003, The Annals of thoracic surgery.

[16]  C. Elias Factors Affecting the Success of Dental Implants , 2011 .

[17]  J. Middleton,et al.  An evaluation of the quality of orthodontic attachment offered by single- and double-mesh bracket bases using the finite element method of stress analysis. , 2009, The Angle orthodontist.

[18]  A. Versluis,et al.  Effect of the inclination of a maxillary central incisor on periodontal stress: finite element analysis. , 2012, The Angle orthodontist.

[19]  B Melsen,et al.  The rate and the type of orthodontic tooth movement is influenced by bone turnover in a rat model. , 2000, European journal of orthodontics.

[20]  Vamsi Krishna Dommeti,et al.  Stress distribution of overdenture using odd number implants - A Finite Element Study. , 2019, Journal of the mechanical behavior of biomedical materials.

[21]  Pana Suttakul,et al.  Effect of Periodontal Ligament on Stress Distribution and Displacement of Tooth and Bone Structure Using Finite Element Simulation , 2015 .

[22]  Sandipan Roy,et al.  Finite-Element analysis of a lateral femoro-tibial impact on the total knee arthroplasty , 2020, Comput. Methods Programs Biomed..

[23]  Senka Mestrović,et al.  Finite element method analysis of the tooth movement induced by orthodontic forces. , 2003, Collegium antropologicum.

[24]  Y C Loo,et al.  Application of finite element method in dental implant research , 2009 .

[25]  A. Navid,et al.  Investigation of the optimal design of orthodontic mini-implants based on the primary stability: A finite element analysis , 2019, Journal of dental research, dental clinics, dental prospects.