Inter‐ and intra‐image variability in computer‐assisted optic nerve head assessment

A computer‐assisted system for optic nerve head analysis was used to measure one eye from each of 15 subjects. These comprised three groups of five, being glaucomatous, ocular hypertensive, and normal subjects. Each eye was imaged with the system 10 times. The 150 images produced were analysed in a randomized masked fashion to test the inter‐image variability of the measurements. Linear pallor: disc ratios had mean coefficients of variation of 6.6% (normal), 4.8%. (ocular hypertensive) and 2.6% (glaucomatous). This trend of reducing coefficient of variation from normal to ocular hypertensive to glaucomatous was reflected in other parameters also. Intra‐image variability was assessed by analysing one image from each subject 10 times, in a randomized masked fashion. The mean coefficients of variation of the linear pallor: disc ratios were 6.3%. (normal), 3.6% (ocular hypertensive) and 3.2% (glaucomatous). Fisher's F test showed that no parameters had significantly lower intra‐image rather than inter‐image variance (at the 5% level). Variability is apparently due to operator variations rather than the image variations.

[1]  P. Nagin,et al.  Detection of increased pallor over time. Computerized image analysis in untreated ocular hypertension. , 1985, Ophthalmology.

[2]  M. B. Shields,et al.  Reproducibility of topographic measurements with the optic nerve head analyzer. , 1987, American journal of ophthalmology.

[3]  RELIABILITY OF PHOTOMETRIC MEASUREMENTS IN THE ZEISS FUNDUS CAMERA , 1983, Acta ophthalmologica.

[4]  J. Gloster Vertical ovalness of glaucomatous cupping. , 1975, The British journal of ophthalmology.

[5]  U Klingbeil,et al.  Reproducibility of optic disc measurements with computerized analysis of stereoscopic video images. , 1986, Archives of ophthalmology.

[6]  M. Wax,et al.  Variability and reproducibility of optic disk topographic measurements with the Rodenstock Optic Nerve Head Analyzer. , 1988, American journal of ophthalmology.

[7]  D G Falconer,et al.  Digital measurement of pallor-disc ratio. , 1980, Archives of ophthalmology.

[8]  P. Nagin,et al.  The reproducibility of computerized boundary analysis for measuring optic disc pallor in the normal optic disc. , 1985, Ophthalmology.

[9]  M F Armaly The correlation between appearance of the optic cup and visual function. , 1969, Transactions - American Academy of Ophthalmology and Otolaryngology. American Academy of Ophthalmology and Otolaryngology.

[10]  R Varma,et al.  Agreement between clinicians and an image analyzer in estimating cup-to-disc ratios. , 1989, Archives of ophthalmology.

[11]  R. Webb,et al.  Confocal scanning laser ophthalmoscope. , 1987, Applied optics.

[12]  T. Cornsweet,et al.  Reliability of optic disk topographic measurements recorded with a video-ophthalmograph. , 1984, American journal of ophthalmology.

[13]  J. M. Miller,et al.  Quantitative evaluation of the optic nerve head in patients with unilateral visual field loss from primary open-angle glaucoma. , 1987, Ophthalmology.

[14]  M J Cox,et al.  Computer‐assisted optic nerve head assessment , 1991, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.

[15]  Tom N. Cornsweet,et al.  Quantification of the Shape and Color of the Optic Nerve Head , 1983 .

[16]  H Alanko,et al.  DEMONSTRATION OF GLAUCOMATOUS OPTIC DISC CHANGES BY ELECTRONIC SUBTRACTION , 1980, Acta ophthalmologica.

[17]  J Bille,et al.  Digital laser scanning fundus camera. , 1987, Applied optics.

[18]  R. Webb,et al.  Flying spot TV ophthalmoscope. , 1980, Applied optics.

[19]  B. J. Winer Statistical Principles in Experimental Design , 1992 .