Instrumentation and control

This chapter examines the instrumentation used to monitor and control fermentation processes. Sensors and other devices used to measure, and thus control, process variables such as temperature, pH, pressure, and dissolved oxygen are considered. Methods to determine the flow rates of both gases and liquids, together with their compositional analysis, are also described. Ion-specific and biosensors together with near infrared spectroscopy used in the monitoring and control of fermentations are discussed. Control systems both manual and automatic are described. These include control strategies such as feedback, feed-forward, cascade, anticipatory, and inferential control together with control functions including PID control. Finally, the use of computers in monitoring and control of fermentations is considered.

[1]  I. J. Higgins,et al.  Principles and application of biosensors in microbiology. , 1987, Society for Applied Bacteriology symposium series.

[2]  Alexandre Restrepo,et al.  Cost effective control strategy for small applications and pilot plants: on–off valves with temporized PID controller , 2002 .

[3]  D Matteuzzi,et al.  A near‐infrarod spectroscopy technique for the control of fermentation processes: An application to lactic acid fermentation , 1994, Biotechnology and bioengineering.

[4]  P. Mizsey,et al.  Computer control of pH and DO in a laboratory fermenter using a neural network technique , 2004, Bioprocess and biosystems engineering.

[5]  Stephen W. Carleysmith Data Handling for Fermentation Development - An Industrial Approach , 1989 .

[6]  Brian McNeil,et al.  Near‐infrared spectroscopic monitoring of biomass, glucose, ethanol and protein content in a high cell density baker's yeast fed‐batch bioprocess , 2006, Yeast.

[7]  J. Sánchez-Rojas,et al.  Temperature dependence of grape must refractive index and its application to winemaking monitoring , 2016 .

[8]  U. Viesturs,et al.  Foam in microbiological processes , 1982 .

[9]  Use of an immobilized penicillinase electrode in the monitoring of the penicillin fermentation. , 1979 .

[10]  M. C. Whiteside,et al.  Computers in fermentation , 1989 .

[11]  R. Srivastava,et al.  Performance of batch, fed-batch, and continuous A-B-E fermentation with pH-control. , 2011, Bioresource technology.

[12]  Rintu Banerjee,et al.  Optimization of culture parameters for extracellular protease production from a newly isolated Pseudomonas sp. using response surface and artificial neural network models , 2004 .

[13]  Govind Rao,et al.  Phase fluorometric sterilizable optical oxygen sensor , 1994, Biotechnology and bioengineering.

[14]  W. Fred Ramirez,et al.  Dynamic hybrid neural network model of an industrial fed-batch fermentation process to produce foreign protein , 2007, Comput. Chem. Eng..

[15]  D. H. Phillips,et al.  Measurement of dissolved oxygen in fermentations , 1961 .

[16]  Pekka Linko,et al.  Neural network modelling for real-time variable estimation and prediction in the control of glucoamylase fermentation , 1992 .

[17]  Pauline M. Doran,et al.  Bioprocess Engineering Principles , 1995 .

[18]  Rui Oliveira,et al.  Online Control Strategies , 2019, Comprehensive Biotechnology.

[19]  A C C Gibbs,et al.  Data Analysis , 2009, Encyclopedia of Database Systems.

[20]  Henry Y. Wang,et al.  Computer‐aided baker's yeast fermentations , 1977, Biotechnology and bioengineering.

[21]  A. K. Bag,et al.  Monitoring the Fermentation Process and Detection of Optimum Fermentation Time of Black Tea Using an Electronic Tongue , 2015, IEEE Sensors Journal.

[22]  Ken Gary,et al.  General Aspects of the Use of Sensors in Biotechnology with Special Emphasis on Cell Cultivation , 1988 .

[23]  Alain Vande Wouwer,et al.  Robust adaptive control of yeast fed-batch cultures , 2008, Comput. Chem. Eng..

[24]  Joseph S. Alford,et al.  Bioprocess control: Advances and challenges , 2006, Comput. Chem. Eng..

[25]  Sing Kiong Nguang,et al.  Soft sensors for on-line biomass measurements , 2004, Bioprocess and biosystems engineering.

[26]  Alisa Rudnitskaya,et al.  Sensor systems, electronic tongues and electronic noses, for the monitoring of biotechnological processes , 2008, Journal of Industrial Microbiology & Biotechnology.

[27]  George T. Tsao,et al.  Dissolved oxygen electrodes , 1979 .

[28]  Ming-Feng Jang,et al.  Robust adaptive controller for continuous bioreactors , 2013 .

[29]  U. Viesturs,et al.  Oxygen and Temperature Control during the Cultivation of Microorganisms using Substrate Feeding , 2007 .

[30]  Juris Vanags,et al.  Development and application of a flexible controller in yeast fermentations using pO2 cascade control , 2010 .

[31]  Hisbullah,et al.  Comparative evaluation of various control schemes for fed-batch fermentation , 2002 .

[33]  Ge Wu Measurement and Instrumentation , 2010 .

[34]  G. Montague,et al.  Enhanced supervision of recombinant E. coli fermentation via artificial neural networks , 1994 .

[35]  Elmer L. Gaden,et al.  Automatic control of dissolved oxygen levels in fermentations , 1962 .

[36]  K Shimizu,et al.  Adaptive on‐line optimizing control of bioreactor systems , 1989, Biotechnology and bioengineering.

[37]  K. Gernaey,et al.  Application of near‐infrared spectroscopy for monitoring and control of cell culture and fermentation , 2009, Biotechnology progress.

[38]  J. Páca,et al.  Development and Verification of the Control System for Fed-Batch Phenol Degradation Processes , 2002 .

[39]  Marvin Charles,et al.  On‐line measurement of gas‐exchange conditions in fermentation processes , 1975 .

[40]  Hu Zhu,et al.  pH-control modes in a 5-L stirred-tank bioreactor for cell biomass and exopolysaccharide production by Tremella fuciformis spore. , 2011, Bioresource technology.

[41]  Ashok Mulchandani,et al.  Developments and applications of biosensors , 1988 .

[42]  Arthur E. Humphrey,et al.  Mixing times and glucose uptake measured with a fluorometer , 1978 .

[43]  D. S. Flynn Instrumentation for Fermentation Processes , 1983 .

[44]  H Honda,et al.  Fuzzy control of bioprocess. , 2000, Journal of bioscience and bioengineering.

[45]  M N Karim,et al.  Artificial neural networks in bioprocess state estimation. , 1992, Advances in biochemical engineering/biotechnology.

[46]  F. G. Shinskey,et al.  pH and pIon control in process and waste streams , 1973 .

[47]  R. Müller,et al.  Methods to optimize myxobacterial fermentations using off-gas analysis , 2012, Microbial Cell Factories.

[48]  Denis Dochain,et al.  Oxygen Control for an Industrial Pilot-Scale Fed-Batch Filamentous Fungal Fermentation , 2007 .

[49]  Kapil G. Gadkar,et al.  On-line adaptation of neural networks for bioprocess control , 2005, Comput. Chem. Eng..

[50]  Kazuyuki Shimizu,et al.  An overview on the control system design of bioreactors , 1993 .

[51]  D. Harrison,et al.  Fluorimetric technique for monitoring changes in the level of reduced nicotinamide nucleotides in continuous cultures of microorganisms. , 1970, Applied microbiology.

[52]  Emil Petre,et al.  Adaptive and robust-adaptive control strategies for anaerobic wastewater treatment bioprocesses , 2013 .

[53]  James Gomes,et al.  Precise control of dissolved oxygen in bioreactors – a model-based geometric algorithm , 2000 .

[54]  L. Kjaergaard,et al.  The redox potential: Its use and control in biotechnology , 1977 .

[55]  Patrick N. Royce,et al.  A Discussion of Recent Developments in Fermentation Monitoring and Control from a Practical Perspective , 1993 .

[56]  Mi‐Sun Kim,et al.  Effect of the accuracy of pH control on hydrogen fermentation. , 2015, Bioresource technology.

[57]  B. Strehlitz,et al.  Biosensor online control of citric acid production from glucose by Yarrowia lipolytica using semicontinuous fermentation , 2010 .

[58]  Ana Maria Frattini Fileti,et al.  A fuzzy-split range control system applied to a fermentation process. , 2013, Bioresource technology.

[59]  Marina Lotti,et al.  Laboratory evolution of copper tolerant yeast strains , 2012, Microbial Cell Factories.

[60]  Reinhold Carle,et al.  On-line application of near infrared (NIR) spectroscopy in food production , 2015 .

[61]  H. Schwan Electrical properties of tissue and cell suspensions. , 1957, Advances in biological and medical physics.

[62]  Michael J. Schöning,et al.  Electrochemical sensor array for bioprocess monitoring , 2011 .

[63]  H. Schneckenburger,et al.  Fluorescence techniques in biotechnology , 1985 .

[64]  Martin Healey,et al.  Principles of automatic control , 1967 .

[65]  N. F. Thornhill,et al.  Computer Applications in Fermentation Technology: Modelling and Control of Biotechnological Processes , 1989 .

[66]  John H. T. Luong,et al.  Instrumentation and Analytical Methods , 2011 .

[67]  A J Morris,et al.  Fermentation monitoring and control: a perspective. , 1989, Biotechnology & genetic engineering reviews.