High precise haptic device for the robotic catheter navigation system

A study on haptic feedback of the master side for an interventional surgical robot system plays a critical important role in the master-slave vascular interventional surgery robot system with haptic feedback, and accuracy control of force feedback is an important means to improve accuracy of the vascular interventional surgery robot teleoperation. Focus on the problem of lacking haptic feedback and accurate control of force feedback in the master-slave interventional surgical robot system, we designed a novel operation control handle in the master, a more in line with the operation of human engineering during the operation process. It can not only get the haptic feedback information from the operation control handle effectively, but also realize the precise force feedback control of the master-slave vascular intervention surgical robot system. The theoretical analysis and the corresponding experimental verification clearly demonstrated that the doctors' operation on the master side is more real and more precise feeling the force feedback information, and effectively improves precision of the master-slave manipulation. The final results show that the accuracy control of force feedback was greatly enhanced in the aspect of reality and the operation efficiency during the doctor operation process.

[1]  I. Singh Robotics in urological surgery: Review of current status and maneuverability, and comparison of robot-assisted and traditional laparoscopy , 2011, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[2]  Shuxiang Guo,et al.  A proximal push force-based force feedback algorithm for robot-assisted vascular intervention surgery , 2015, 2015 IEEE International Conference on Mechatronics and Automation (ICMA).

[3]  Shuxiang Guo,et al.  Clamping Force Evaluation For A Robotic Catheter Navigation System , 2013 .

[4]  Nan Xiao,et al.  A novel robotic catheter system with force and visual feedback for vascular interventional surgery , 2012, Int. J. Mechatronics Autom..

[5]  Shuxiang Guo,et al.  Development of a kind of robotic catheter manipulation system , 2011, 2011 IEEE International Conference on Robotics and Biomimetics.

[6]  Shuxiang Guo,et al.  A force acquisition method in a catheter navigation system , 2013, 2013 ICME International Conference on Complex Medical Engineering.

[7]  N. Cheshire,et al.  Clinical applications of robotic technology in vascular and endovascular surgery. , 2011, Journal of vascular surgery.

[8]  Jinwoo Jung,et al.  An evaluation of closed-loop control options for continuum manipulators , 2012, 2012 IEEE International Conference on Robotics and Automation.

[9]  N. Cheshire,et al.  Evaluation of robotic endovascular catheters for arch vessel cannulation. , 2011, Journal of vascular surgery.

[10]  Shuxiang Guo,et al.  Design of a surgeon's controller for catheter navigation , 2013, 2013 IEEE International Conference on Mechatronics and Automation.

[11]  Shuxiang Guo,et al.  Vascular elasticity determined mass-spring model for virtual reality simulators , 2015, Int. J. Mechatronics Autom..

[12]  Qiang Gao,et al.  Design and performance evaluation of a novel robotic catheter system for vascular interventional surgery , 2015, Microsystem Technologies.

[13]  J. Brachmann,et al.  Atrial fibrillation ablation using a robotic catheter remote control system: initial human experience and long-term follow-up results. , 2008, Journal of the American College of Cardiology.

[14]  Robert D. Howe,et al.  Force control of flexible catheter robots for beating heart surgery , 2011, 2011 IEEE International Conference on Robotics and Automation.

[15]  Shuxiang Guo,et al.  Evaluating performance of a novel developed robotic catheter manipulating system , 2013 .

[16]  J. Bismuth,et al.  Feasibility and Safety of Remote Endovascular Catheter Navigation in a Porcine Model , 2011, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[17]  Shuxiang Guo,et al.  A novel force feedback interventional surgery robotic system , 2015, 2015 IEEE International Conference on Mechatronics and Automation (ICMA).

[18]  Constantinos Mavroidis,et al.  Magnetic resonance-compatible robotic and mechatronics systems for image-guided interventions and rehabilitation: a review study. , 2007, Annual review of biomedical engineering.

[19]  Xu Ma Development of a Novel Robotic Catheter Manipulating System with Fuzzy PID Control , 2018 .

[20]  Giovanni Amoroso,et al.  Use of the Stereotaxis Niobe® magnetic navigation system for percutaneous coronary intervention: Results from 350 consecutive patients , 2008, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[21]  Shuxiang Guo,et al.  A robotic catheter system with real-time force feedback and monitor , 2012, Australasian Physical & Engineering Sciences in Medicine.

[22]  Hedyeh Rafii-Tari,et al.  Current and Emerging Robot-Assisted Endovascular Catheterization Technologies: A Review , 2013, Annals of Biomedical Engineering.

[23]  Shuxiang Guo,et al.  Safety Operation Consciousness Realization of a MR Fluids-Based Novel Haptic Interface for Teleoperated Catheter Minimally Invasive Neurosurgery , 2016, IEEE/ASME Transactions on Mechatronics.

[24]  Rajesh Aggarwal,et al.  Role of virtual reality simulation in teaching and assessing technical skills in endovascular intervention. , 2010, Journal of vascular and interventional radiology : JVIR.

[25]  Hugh Calkins,et al.  First experience with a novel robotic remote catheter system: Amigo™ mapping trial , 2013, Journal of Interventional Cardiac Electrophysiology.

[26]  S. Willems,et al.  Reduced Fluoroscopy During Atrial Fibrillation Ablation: Benefits of Robotic Guided Navigation , 2010, Journal of cardiovascular electrophysiology.

[27]  Shuxiang Guo,et al.  Study on haptic feedback functions for an interventional surgical robot system , 2015, 2015 IEEE International Conference on Mechatronics and Automation (ICMA).

[28]  Neville Dastur,et al.  Use of a remotely steerable "robotic" catheter in a branched endovascular aortic graft. , 2012, Journal of vascular surgery.