Small cantilevers for force spectroscopy of single molecules

We have used a simple process to fabricate small rectangular cantilevers out of silicon nitride. They have lengths of 9–50 μm, widths of 3–5 μm, and thicknesses of 86 and 102 nm. We have added metallic reflector pads to some of the cantilever ends to maximize reflectivity while minimizing sensitivity to temperature changes. We have characterized small cantilevers through their thermal spectra and show that they can measure smaller forces than larger cantilevers with the same spring constant because they have lower coefficients of viscous damping. Finally, we show that small cantilevers can be used for experiments requiring large measurement bandwidths, and have used them to unfold single titin molecules over an order of magnitude faster than previously reported with conventional cantilevers.

[1]  H. Callen,et al.  Irreversibility and Generalized Noise , 1951 .

[2]  Calvin F. Quate,et al.  Microfabrication of cantilever styli for the atomic force microscope , 1990 .

[3]  D. Sarid Scanning Force Microscopy: With Applications To Electric, Magnetic, And Atomic Forces , 1991 .

[4]  O. Wolter,et al.  Micromachined silicon sensors for scanning force microscopy , 1991 .

[5]  T. B. Gabrielson,et al.  Fundamental noise limits for miniature acoustic and vibration sensors , 1991 .

[6]  K. Schiffmann Investigation of fabrication parameters for the electron-beam-induced deposition of contamination tips used in atomic force microscopy , 1993 .

[7]  T. Gabrielson Mechanical-thermal noise in micromachined acoustic and vibration sensors , 1993 .

[8]  J. Bechhoefer,et al.  Calibration of atomic‐force microscope tips , 1993 .

[9]  H. Gaub,et al.  Intermolecular forces and energies between ligands and receptors. , 1994, Science.

[10]  David A. Kidwell,et al.  Sensing Discrete Streptavidin-Biotin Interactions with Atomic Force Microscopy , 1994 .

[11]  Hans-Jürgen Butt,et al.  Height calibration of optical lever atomic force microscopes by simple laser interferometry , 1995 .

[12]  Gus Gurley,et al.  Short cantilevers for atomic force microscopy , 1996 .

[13]  Paul K. Hansma,et al.  Studies of vibrating atomic force microscope cantilevers in liquid , 1996 .

[14]  D. Johannsmann,et al.  Distance-dependent noise measurements in scanning force microscopy , 1996 .

[15]  E. Evans,et al.  Dynamic strength of molecular adhesion bonds. , 1997, Biophysical journal.

[16]  Deron A. Walters,et al.  Atomic force microscopy using small cantilevers , 1997, Photonics West.

[17]  Deron A. Walters,et al.  Atomic force microscope for small cantilevers , 1997, Photonics West.

[18]  M. Rief,et al.  Reversible unfolding of individual titin immunoglobulin domains by AFM. , 1997, Science.

[19]  Matthias Rief,et al.  Single Molecule Force Spectroscopy on Polysaccharides by Atomic Force Microscopy , 1997, Science.

[20]  Arun Majumdar,et al.  Optimization and performance of high-resolution micro-optomechanical thermal sensors , 1997 .

[21]  J. Sader Frequency response of cantilever beams immersed in viscous fluids with applications to the atomic force microscope , 1998 .

[22]  C. F. Schmidt,et al.  Thermal noise limitations on micromechanical experiments , 1998, European Biophysics Journal.