Risk assessment of formaldehyde in typical office buildings in Taiwan.

Our study conducts a series of investigations in five office buildings chosen according to the types of construction, ventilation, and building age. Formaldehyde was measured by continuous photoacoustic Multi-Gas monitor Type 1302 (Brüel & Kjaer). The 8-h average concentrations in working hours were used to estimate the lifetime cancer probability (LCP) and chronic non-carcinogenic hazard index (HI). The carcinogenic effect of formaldehyde estimate by LCP (70 years old) is about 2.06 x 10(-4) to 1.75 x 10(-3) after adjusting their working time. The levels of risk are 100-1000 times of the acceptable carcinogenic risk. A similar trend is observed for the levels of HI calculated. Many studies have suggested that exposure to high levels of formaldehyde may cause nasal cancer and other health effects. Therefore, promoting the labeling system for low emission materials to protect consumers from exposure to excessive emissions and helping the industry to develop low emission materials is evidently urgent and deserves greater efforts.

[1]  T. Woodruff,et al.  Air Toxics and Health Risks in California: The Public Health Implications of Outdoor Concentrations , 2000, Risk analysis : an official publication of the Society for Risk Analysis.

[2]  M J Abramson,et al.  Increased risk of allergy in children due to formaldehyde exposure in homes , 1999, Allergy.

[3]  M L Dourson,et al.  Regulatory history and experimental support of uncertainty (safety) factors. , 1983, Regulatory toxicology and pharmacology : RTP.

[4]  P. Dingle,et al.  Reducing Formaldehyde Exposure in Office Environments Using Plants , 2000, Bulletin of environmental contamination and toxicology.

[5]  I. Andersen,et al.  Indoor air pollution due to chipboard used as a construction material , 1975 .

[6]  M. Casanova,et al.  Pharmacodynamics of formaldehyde: applications of a model for the arrest of DNA replication by DNA-protein cross-links. , 1999, Toxicology and applied pharmacology.

[7]  Peder Wolkoff,et al.  Impact of air velocity, temperature, humidity, and air on long-term voc emissions from building products , 1998 .

[8]  M. Götz,et al.  Exposure to gaseous formaldehyde induces IgE‐mediated sensitization to formaldehyde in school‐children , 1996, Clinical and experimental allergy : journal of the British Society for Allergy and Clinical Immunology.

[9]  J. Hebel,et al.  Formaldehyde dose-response in healthy nonsmokers. , 1987, JAPCA.

[10]  M A Woodbury,et al.  Formaldehyde exposure in nonoccupational environments. , 1981, Archives of environmental health.

[11]  T J Woodruff,et al.  Estimating cancer risk from outdoor concentrations of hazardous air pollutants in 1990. , 2000, Environmental research.

[12]  K.W.D. Cheong,et al.  Development and application of an indoor air quality audit to an air-conditioned building in Singapore , 2001 .